Towns / Granby / Inland Wetlands & Watercourses Commission / Jul 8, 2026
Inland Wetlands & Watercourses Commission, Jul 8, 2026
Granby Inland Wetlands & Watercourses Commission Hide agendas that already have minutesDocuments
| Type | Document | Pages | Open |
|---|---|---|---|
| minutesminutes | IWWC Minutes | 6 | PDF download · town site |
| agenda | IWWC Agenda | 2 | PDF download · town site |
| packetpacket | IWWC Meeting Packet Not attached: this packet is 86 MB, too large to host here. Use the town site link. |
374 | town site |
Summary of the minutes
AI-generated summary. Each line links to the PDF page it came from; check it before relying on it.
Read the official minutes (PDF, 6 pages) The PDF is the record; this summary is a guide to it.
At its July 8, 2026 meeting, the Granby Inland Wetlands and Watercourses Commission approved the June 10, 2026 minutes and approved permits for 94 Quarry Road and 86 Case Street, with conditions for the latter. It continued several applications and hearings, delegated the 63 Harmony Hill Road subdivision to the Agent, and upheld the Enforcement Order for 7 Laurel Drive.
Decisions (11) · all reported votes
- Approval of June 10, 2026 Meeting Minutes
Approved as presented
Vote: Motion by F. Jones, second by D. Tolli, carried 5-0-1 (J. Laudati abstained) · p. 1 - 94 Quarry Road – J. Fort – Permit to place a 12' x 28' prefabricated garage on crushed stone within a regulated area
Approved application and draft approval letter as presented
Vote: Motion by S. Okie, second by B. Schmitt, carried 6-0-0 · p. 1 - 86 Case Street – J. Vosburgh – Permit to construct a single-family home with site improvements within a regulated area
Approved application and draft approval letter as amended, with conditions: (1) Mylar copy of approved plans filed on Land Records prior to building permit; (2) Mylar copy of final As-Built Drawing filed prior to Certificate of Occupancy; (3) wetland delineation shown as 'General Limits', and any additional proposed activities require a new wetland delineation
Vote: Motion by B. Schmitt, second by F. Jones, carried 5-0-0 · p. 1, p. 2 - 5 Godard Road – H. Werner and S. Werner – Permit to construct a single-family home and detached garage within a regulated area
Received and continued to the next regular meeting; Agent K. Bednaz to conduct a site visit and requested better-defined limits of clearing and consideration of shifting the house location
Vote: Motion by D. Tolli, second by S. Okie, carried 6-0-0 · p. 2 - 63 Harmony Hill Road – Roswell Development, LLC – Permit for 8-lot single-family residential subdivision within a regulated area
Delegated to the IWWC Agent for review and approval
Vote: Motion by B. Schmitt, second by N. Dethlefsen, carried 5-0-0 · p. 3 - 215 Salmon Brook Street – Town of Granby – Permit to construct a 24' x 12' gazebo on a concrete pad and install eight benches within a regulated area
Received and continued to the next regular meeting
Vote: Motion by S. Okie, second by F. Jones, carried 6-0-0 · p. 3 - 199 Broad Hill Road – T. Kurnicki – Public hearing on permit to construct a single-family home within a regulated area
Public hearing continued to the next regular meeting; Agent recommended applicant provide a Landscaping Plan, modified construction sequence, enhanced E&S controls, seed mixes for steep slopes, and an invasive species management plan
Vote: Motion by B. Schmitt, second by S. Okie, carried 6-0-0 · p. 3, p. 4 - 37 Hartford Avenue – F. Devine – Public hearing on permit for a 16-unit apartment building within regulated areas 10,145 square feet 4,642 square feet
Public hearing continued to the next regular meeting at applicant's request so revised plans can address staff comments
Vote: Motion by N. Dethlefsen, second by F. Jones, carried 6-0-0 · p. 4 - 7 Laurel Drive – C. Fontaine and R. Weiner – Show Cause Hearing on regulated activity without a valid IWWC Permit
Enforcement Order upheld and item continued to the next regular meeting
Vote: Motion by F. Jones, second by D. Tolli, carried 5-0-0 · p. 5 - 142R and 186 Case Street – M. Reale c/o Scottinaleece, LLC – Update on regulated activity without a valid IWWC Permit
Agenda item continued to the next regular meeting
Vote: Motion by J. Laudati, second by B. Schmitt, carried 5-0-0 · p. 5 - Adjournment
Meeting adjourned at 9:55 p.m.
Vote: Motion by N. Dethlefsen, second by J. Laudati, carried 6-0-0 · p. 6
Also discussed (3)
- 138 Day Street – Reinhard Maier c/o The Reinhard W. Maier Living Trust – Rear addition within a regulated area: Reported as Authorized Agent approval on 6/15/26 (no Commission vote) · p. 5
- 65 Cider Mill Heights – C. Jensen – 12' x 16' prefabricated shed on crushed stone base within a regulated area: Reported as Authorized Agent approval on 6/24/26 (no Commission vote) · p. 5
- 65, 79 and 87 Barkhamsted Road – C. McGee – Regulated activity without a valid IWWC Permit: Notice of Violation issued 5/28/26; property owner to work with staff to address the matter; updates to be provided as necessary · p. 6
Summary of the agenda: IWWC Agenda
AI-generated summary.
This is the July 8, 2026 agenda for the Granby Inland Wetlands and Watercourses Commission, listing permit requests, public hearings, a show cause hearing, and agent reports.
On the agenda (13)
- Action on the June 10, 2026, Meeting Minutes · p. 1
- 94 Quarry Road – J. Fort – Permit request to place a 12' x 28' prefabricated garage on crushed stone within a regulated area (continued from 6/10/26) · p. 1
- 86 Case Street – J. Vosburgh – Permit request to construct a single-family home with associated site improvements within a regulated area (continued from 6/10/26) · p. 1
- 5 Godard Road – H. Werner and S. Werner – Permit request to construct a single-family home and detached garage with associated site improvements within a regulated area (to be received) · p. 1
- 63 Harmony Hill Road – Roswell Development, LLC. – Permit request for an 8-lot single family residential subdivision and associated site work within a regulated area (to be received) · p. 1
- 215 Salmon Brook Street – Town of Granby – Permit request to construct a gazebo on a concrete pad within a regulated area (to be received) · p. 1
- 199 Broad Hill Road – T. Kurnicki – Public hearing on permit request to construct a single-family home with associated site improvements within a regulated area (to open) · p. 1
- 37 Hartford Avenue – F. Devine – Public hearing on permit application for regulated activities for development of a 16-unit apartment building and associated site improvements (to open) · p. 1
- 7 Laurel Drive – C. Fontaine and R. Weiner – Show cause hearing for conducting a regulated activity without a valid IWWC Permit · p. 1
- Update re: 142R and 186 Case Street – M. Reale c/o Scottinaleece, LLC – Agent report on conducting a regulated activity without a valid IWWC Permit · p. 1
- 138 Day Street – Reinhard Maier c/o The Reinhard W. Maier Living Trust – Permit request to construct an 11.5' x 26' single-story rear addition within a regulated area; Authorized Agent approval 6/15/26: (agent report) · p. 1
- 65 Cider Mill Heights – C. Jensen – Permit request to place a 12'x16' prefabricated shed on a 14'x18' crushed stone base with future underground electrical conduit within a regulated area; Authorized Agent approval 6/24/26: (agent report) · p. 1
- 65, 79 and 87 Barkhamsted Road – C. McGee – Conducting a regulated activity without a valid IWWC Permit · p. 2
This PDF is a scan; its text was read by OCR and may contain errors.
Full text of the documents
View the minutes PDF on this page (IWWC Minutes)
Text of the minutes (IWWC Minutes, 6 pages)
Page 1 · open in PDF
1 MEETING MINUTES Town of Granby Inland Wetlands and Watercourses Commission Wednesday, July 8, 2026, at 7:00 pm PRESENT: Nick Dethlefsen, Barbara Schmitt, David Tolli, Susan Okie, John Laudati, and Fred Jones ALSO PRESENT: IWWC Agent Kate Bednaz and Land Use Coordinator Renee Deltenre 1. Call to Order Chair J. Laudati called the meeting to order at 7:01 p.m. 2. Action on the June 10, 2026, Meeting Minutes ON A MOTION by F. Jones seconded by D. Tolli, the Commission voted 5-0-1 to approve the June 10, 2026, minutes as presented. J. Laudati abstained. 3. Permit Requests a. 94 Quarry Road – J. Fort – Permit request to place a 12’ x 28’ prefabricated garage on crushed stone within a regulated area. This application was received and continued from last month’s meeting. The property owner is seeking permission to place a 12’x28’ prefabricated garage on a 14’x30’ crushed stone base with underground electrical within an existing lawn area. The permit request also includes the removal of an existing shed, and the application has been updated to accommodate staff comments. A draft approval letter was provided to the Commission for review and consideration. ON A MOTION by S. Okie seconded by B. Schmitt, the Commission voted 6-0-0 to approve the application and draft approval letter as presented. J. Laudati recused himself at 7:05 p.m. b. 86 Case Street – J. Vosburgh – Permit request to construct a single-family home with associated site improvements within a regulated area. This application was received and continued from last month’s meeting. Applicant Jonathan Vosburgh was present to discuss the application and revisions that were made based on a site inspection conducted by Soil Scientist Ian Cole and Granby’s Wetlands Agent Kate Bednaz. Due to staff concerns regarding hydrology and the wetland delineation due to the placement of fill overtime, both staff and the applicant’s Soil Scientist found common ground with a revised wetland delineation. The orientation of the home has shifted slightly to the west, and a front walkway was added. The Commission discussed whether or not a full wetlands delineation should be required, and if not, outlined additional conditions of approval.
Page 2 · open in PDF
2 ON A MOTION by B. Schmitt seconded by F. Jones, the Commission voted 5-0-0 to approve the application and draft approval letter as amended to include the following conditions: 1. A Mylar copy of the approved plans shall be filed on the Land Records in the Office of the Town Clerk, prior to the issuance of a building permit. 2. A Mylar copy of the final As-Built Drawing shall be filed on the Land Records in the Office of the Town Clerk, prior to the issuance of a Certificate of Occupancy. 3. The wetland’s delineation as shown are “General Limits”, and any additional proposed activities will require the submittal of a new wetland delineation. J. Laudati was reseated at 7:37 p.m. c. 5 Godard Road – H. Werner and S. Werner – Permit request to construct a single- family home and detached garage with associated site improvements within a regulated area. Property owners Harry and Susan Werner, as well as Professional Engineer Guy Hesketh were present to discuss the application. The owners are seeking permission to construct a 3-bedroom single-story home with a detached garage, gravel driveway, paver walkway, front porch, rear deck and rear patio within a regulated area. Soil Scientist William Jackson conducted a wetlands delineation, and his report has been submitted as part of the application. There is an existing farm pond on the property, along with a narrow watercourse that flows towards the north as part of the East Branch of the Salmon Brook. All proposed activities are located within the 200-foot upland review area of the pond and 80% within the 100-foot upland review area of the wetlands. G. Hesketh provided a thorough overview of the plans, including erosion and sedimentation control measures, site grading and drainage, septic design, etc. Perk testing has been conducted, and the proposed septic system will be located within the northeast corner of the site. Questions were raised regarding tree clearing limits and whether or not the house could be shifted to the west, farther away from the wetland’s boundary. At this time, the closest area of disturbance is approximately ten feet from the closest wetlands boundary; Wetlands Flag #A-16. S. Werner informed the Commission of their intent to establish a Conservation Easement over a large portion of the property, similar to their abutting properties to preserve land in its natural state. K. Bednaz will conduct a site visit and requested that the limits of clearing be better defined on the Site Plan and consideration be given to shifting the location of the house. ON A MOTION by D. Tolli seconded by S. Okie, the Commission voted 6-0-0 to receive and continue the application to the next regular meeting. J. Laudati recused himself at 8:15 p.m. d. 63 Harmony Hill Road – Roswell Development, LLC. – Permit request for an 8-lot single family residential subdivision and associated site work within a regulated area.
Page 3 · open in PDF
3 Applicant Jonathan Vosburgh of Roswell Development, LLC was present to discuss the application. He is seeking permission to create eight additional lots as part of a re- subdivision of an existing 6.45-acre parcel known as 63 Harmony Hill Road. Plans have been submitted to the Farmington Valley Heath District for review, and the applicant presents to the Planning and Zoning Commission next week. Soil Scientist Ian Cole conducted a wetlands delineation, and his report has been submitted as part of the application. Based on his findings, there are no wetlands or watercourses on the subject site, and there are no alluvial soils within 100’ of the property line. The brook located on the adjacent parcel known as 290 North Granby Road has clearly defined alluvial soils and is located more than 200 feet from the proposed activities. ON A MOTION by B. Schmitt seconded by N. Dethlefsen, the Commission voted 5-0-0 to delegate the application to the IWWC Agent for review and approval. J. Laudati was reseated at 8:29 p.m. e. 215 Salmon Brook Street – Town of Granby – Permit request to construct a gazebo on a concrete pad within a regulated area. The Town of Granby is seeking permission to construct a 24’ x 12’ gazebo on a concrete pad just southeast of the dog park, parking lot located within the existing lawn area. The application also includes the installation of eight benches throughout the park along the walking trail. The benches will be anchored to an 8’ x 12’ concrete pad, allowing additional space for a wheelchair. Six inches of soil will be excavated, crushed stone will be added and compacted, and then the concrete pad will be poured. ON A MOTION by S. Okie seconded by F. Jones, the Commission voted 6-0-0 to receive and continue the application to the next regular meeting. 4. Public Hearings a. 199 Broad Hill Road – T. Kurnicki – Permit request to construct a single-family home with associated site improvements within a regulated area. Applicant and property owner Thomas Kurnicki was present to discuss the application, which was received and discussed on May 13, 2026, and scheduled for a public hearing this evening. He is seeking permission to construct a single-family home so that he and his family can relocate from California. The 3.04-acre site consists of a challenging terrain with an intermittent watercourse, wetlands soils, a storm drainage ROW in favor of the Town of Granby and is located within the Salmon Brook upland review area. After discussion by the Commission at the May meeting, it was determined that a wetland delineation was required and the applicant has provided revised drawings, as well as a wetland/watercourse delineation report. A memorandum from Professional Engineer TJ Barresi was provided to the Commission, outlining responses to staff comments and concerns. T. Kurnicki ran through the revisions and noted that he is still waiting on approval from the Farmington Valley Health District. Concerns were raised regarding the limits of clearing, proposed grading and lack of a Landscaping Plan. TJ Barresi joined via Zoom to explain the design of the
Page 4 · open in PDF
4 driveway and the grading necessary to meet the standards required as part of the Subdivision Regulations. A stone swale is proposed along the driveway to collect water as it runs down the hill, and the final proposed grades will have less slope than existing conditions. K. Bednaz recommended that the hearing remain open and requested that the applicant provide a Landscaping Plan, modify the construction sequence, enhance E&S control measures, utilize seed mixes for steep slopes, and prepare an invasive species management plan. There was no public comment. ON A MOTION by B. Schmitt seconded by S. Okie, the Commission voted 6-0-0 to continue the public hearing to the next regular meeting. b. 37 Hartford Avenue – F. Devine – Permit application for regulated activities in connection with the development of a 16-unit apartment building and associated site improvements. Professional Engineer Rebecca Li was present to discuss the application, which was received and discussed on June 10, 2026, and scheduled for a public hearing this evening. The applicant is seeking to construct a 16-unit apartment complex on the existing foundation, which will consist of five 1-bedroom units and twelve 2-bedroom units. The subject property is approximately 111,198 square feet and located within the 100-foot wetland upland review area and 200-foot watercourse upland review area (Salmon Brook tributary). Site improvements include, but are not limited to, parking, utilities, stormwater management, site grading, landscaping, lighting, pavilion and dumpster enclosure. Proposed disturbance within the 200-foot upland review area is 10,145 square feet and proposed disturbance within the 100-foot upland review area is 4,642 square feet. R. Li provided an overview of the plans, including erosion and sedimentation control measures, site grading and drainage, septic design, etc. Perk testing has been conducted, and the proposed GST septic system will be located in front of the building, parallel to Hartford Avenue. Plans have been submitted to the Farmington Valley Health District and State of CT Department of Health for review. In response to Commissioner comments, a nitrogen dilution evaluation and sewer extension feasibility analysis were provided. An invasive species management plan will be provided, and additional plantings will be added at the top of the slope. R. Li requested that the hearing remain open so that revised plans may be presented to address staff comments at the next meeting. Public Comment Reinhard Maier, 138 Day Street, expressed concern and referenced the prior application from Vessel RE Holdings, LLC. Robert Flanigan, 24 Woodcliff Drive, expressed concerns regarding the potential impact of the development on the adjacent wetlands and watercourse. Attorney George Schober, Enfield, CT, spoke on behalf of his client Peter Voskowsky, who is an abutting property owner. His client is concerned with the potential for effluent to seep onto his property and requests a third-party independent review of the application.
Page 5 · open in PDF
5 ON A MOTION by N. Dethlefsen seconded by F. Jones, the Commission voted 6-0-0 to continue the public hearing to the next regular meeting. J. Laudati recused himself at 9:25 p.m. 5. Show Cause Hearing a. 7 Laurel Drive – C. Fontaine and R. Weiner – Conducting a Regulated Activity without a valid IWWC Permit. K. Bednaz stated that an Enforcement Order was issued on 7/2/26 to the owners of 7 Laurel Drive, for the placement of a prefabricated shed, split rail fencing and underground drainage piping within a regulated area without a permit. Owners Colleen Fontaine and Ross Weiner were present to discuss the situation and noted that they have retained Attorney Kari Olson to assist with this matter and are engaging with a Soil Scientist. K. Bednaz conducted a site visit on 6/5/26 and provided background information on the property, including the prior Enforcement Order. At this time, erosion and sedimentation control measures have been installed at the request of staff and the property owners plan to have an application submitted in advance of the August meeting. ON A MOTION by F. Jones seconded by D. Tolli, the Commission voted 5-0-0 to uphold the Enforcement Order and continue to the next regular meeting. 6. Agent Report and Correspondence a. Update re: 142R and 186 Case Street – M. Reale c/o Scottinaleece, LLC – Conducting a Regulated Activity without a valid IWWC Permit. Attorney Timothy Furey was present on behalf of the property owner to provide updates. At this time, mapping has been completed by Robert Green Associates, LLC and Soil Scientist David Lord has flagged the property. The property owner has been working with the USDA on his proposed farming activities, and Attorney Furey anticipates that documentation will be provided within the next month. At the last meeting, the Commission made a motion requiring the submittal of the existing conditions plan for the entire site by the next meeting; however, this was not provided. ON A MOTION by J. Laudati seconded by B. Schmitt, the Commission voted 5-0-0 to continue this agenda item to the next regular meeting. J. Laudati was reseated at 9:44 p.m. b. 138 Day Street – Reinhard Maier c/o The Reinhard W. Maier Living Trust – Permit request to construct a 11.5’ x 26’ single-story rear addition within a regulated area. Authorized Agent approval 6/15/26. c. 65 Cider Mill Heights – C. Jensen – Permit request to place a 12’x16’ prefabricated shed on a 14’x18’ crushed stone base with future underground electrical conduit within a regulated area. Authorized Agent approval 6/24/26.
Page 6 · open in PDF
6 d. 65, 79 and 87 Barkhamsted Road – C. McGee – Conducting a Regulated Activity without a valid IWWC Permit. A Notice of Violation was issued on 5/28/26 to the owner of 65, 79 and 87 Barkhamsted Road for the stockpiling of vehicles and various materials within the upland review area of the West Branch of Salmon Brook. K. Bednaz spoke with the property owner this afternoon regarding his property and regulated activities. Mr. McGee will be working with staff to address the matter, and updates will be provided as necessary. K. Bednaz also informed the Commission that the owners of the Station 280 Apartment Complex will install the excess scheduled plantings to the area where trash debris has been an issue. 7. Commissioner Reports and Correspondence None 8. Other Correspondence The Commission received email correspondence from Maureen Eberly in their meeting packet regarding weather patterns in Connecticut. 9. Adjourn ON A MOTION by N. Dethlefsen seconded by J. Laudati, the Commission voted 6-0-0 to adjourn the meeting at 9:55 p.m. Respectfully submitted, Renee Deltenre Land Use Coordinator
View the agenda PDF on this page (IWWC Agenda)
Text read from the scanned agenda (OCR) (IWWC Agenda, 2 pages)
Page 1 · open in PDF
Town of Granby Inland Wetlands and Watercourses Commission Regular Meeting Agenda Wednesday, July 8, 2026, at 7:00 pm Town Hall Meeting Room Zoom: https://us02web.zoom.us/j/81245552872?pwd=UxQHF44PB4btTxzwa1zqYeF4is75Ua.1 Call In: 929-205-6099 Meeting ID: 812 4555 2872 Passcode: 486172 1. Call to Order 2. Action on the June 10, 2026, Meeting Minutes 3. Permit Requests a. 94 Quarry Road – J. Fort – Permit request to place a 12' x 28' prefabricated garage on crushed stone within a regulated area. (Continued from 6/10/26) b. 86 Case Street – J. Vosburgh – Permit request to construct a single-family home with associated site improvements within a regulated area. (Continued from 6/10/26) c. 5 Godard Road – H. Werner and S. Werner – Permit request to construct a single-family home and detached garage with associated site improvements within a regulated area. (To be received) d. 63 Harmony Hill Road – Roswell Development, LLC. – Permit request for an 8-lot single family residential subdivision and associated site work within a regulated area. (To be received) e. 215 Salmon Brook Street – Town of Granby – Permit request to construct a gazebo on a concrete pad within a regulated area. (To be received) 4. Public Hearings a. 199 Broad Hill Road – T. Kurnicki – Permit request to construct a single-family home with associated site improvements within a regulated area. (To Open) b. 37 Hartford Avenue – F. Devine – Permit application for regulated activities in connection with the development of a 16-unit apartment building and associated site improvements. (To Open) 5. Show Cause Hearing a. 7 Laurel Drive – C. Fontaine and R. Weiner – Conducting a Regulated Activity without a valid IWWC Permit. 6. Agent Report and Correspondence a. Update re: 142R and 186 Case Street – M. Reale c/o Scottinaleece, LLC – Conducting a Regulated Activity without a valid IWWC Permit. b. 138 Day Street – Reinhard Maier c/o The Reinhard W. Maier Living Trust – Permit request to construct a 11.5' x 26' single-story rear addition within a regulated area. Authorized Agent approval 6/15/26. c. 65 Cider Mill Heights – C. Jensen – Permit request to place a 12'x16' prefabricated shed on a 14'x18' crushed stone base with future underground electrical conduit within a regulated area. Authorized Agent approval 6/24/26. Please note: Any person who wishes to provide materials for display on the video monitors at an IWWC meeting where such monitors are being used to videoconference the meetings must email the materials no later than 10 AM on the day of the meeting. All materials must be contained in a single attachment to the email. Materials received after the 10 AM deadline will not be accepted for display. Display of the materials is subject to all other rules and procedures of the IWWC. Zip drive, memory sticks and other data storage devices will not be accepted.
Page 2 · open in PDF
Town of Granby Inland Wetlands and Watercourses Commission Regular Meeting Agenda Wednesday, July 8, 2026, at 7:00 pm Town Hall Meeting Room d. 65, 79 and 87 Barkhamsted Road – C. McGee – Conducting a Regulated Activity without a valid IWWC Permit. 7. Commissioner Reports and Correspondence 8. Other Correspondence 9. Adjourn Please note: Any person who wishes to provide materials for display on the video monitors at an IWWC meeting where such monitors are being used to videoconference the meetings must email the materials no later than 10 AM on the day of the meeting. All materials must be contained in a single attachment to the email. Materials received after the 10 AM deadline will not be accepted for display. Display of the materials is subject to all other rules and procedures of the IWWC. Zip drive, memory sticks and other data storage devices will not be accepted.
Text of the packet (IWWC Meeting Packet, 374 pages)
Page 1
Town of Granby Inland Wetlands and Watercourses Commission Regular Meeting Agenda Wednesday, July 8, 2026, at 7:00 pm Town Hall Meeting Room Please note: Any person who wishes to provide materials for display on the video monitors at an IWWC meeting where such monitors are being used to videoconference the meetings must email the materials no later than 10 AM on the day of the meeting. All materials must be contained in a single attachment to the email. Materials received after the 10 AM deadline will not be accepted for display. Display of the materials is subject to all other rules and procedures of the IWWC. Zip drive, memory sticks and other data storage devices will not be accepted. Zoom: https://us02web.zoom.us/j/81245552872?pwd=UxQHF44PB4btTxzwa1zqYeF4is75Ua.1 Call In: 929-205-6099 Meeting ID: 812 4555 2872 Passcode: 486172 1. Call to Order 2. Action on the June 10, 2026, Meeting Minutes 3. Permit Requests a. 94 Quarry Road – J. Fort – Permit request to place a 12’ x 28’ prefabricated garage on crushed stone within a regulated area. (Continued from 6/10/26) b. 86 Case Street – J. Vosburgh – Permit request to construct a single-family home with associated site improvements within a regulated area. (Continued from 6/10/26) c. 5 Godard Road – H. Werner and S. Werner – Permit request to construct a single-family home and detached garage with associated site improvements within a regulated area. (To be received) d. 63 Harmony Hill Road – Roswell Development, LLC. – Permit request for an 8-lot single family residential subdivision and associated site work within a regulated area. (To be received) e. 215 Salmon Brook Street – Town of Granby – Permit request to construct a gazebo on a concrete pad within a regulated area. (To be received) 4. Public Hearings a. 199 Broad Hill Road – T. Kurnicki – Permit request to construct a single-family home with associated site improvements within a regulated area. (To Open) b. 37 Hartford Avenue – F. Devine – Permit application for regulated activities in connection with the development of a 16-unit apartment building and associated site improvements. (To Open) 5. Show Cause Hearing a. 7 Laurel Drive – C. Fontaine and R. Weiner – Conducting a Regulated Activity without a valid IWWC Permit. 6. Agent Report and Correspondence a. Update re: 142R and 186 Case Street – M. Reale c/o Scottinaleece, LLC – Conducting a Regulated Activity without a valid IWWC Permit. b. 138 Day Street – Reinhard Maier c/o The Reinhard W. Maier Living Trust – Permit request to construct a 11.5’ x 26’ single-story rear addition within a regulated area. Authorized Agent approval 6/15/26. c. 65 Cider Mill Heights – C. Jensen – Permit request to place a 12’x16’ prefabricated shed on a 14’x18’ crushed stone base with future underground electrical conduit within a regulated area. Authorized Agent approval 6/24/26.
Page 2
Town of Granby Inland Wetlands and Watercourses Commission Regular Meeting Agenda Wednesday, July 8, 2026, at 7:00 pm Town Hall Meeting Room Please note: Any person who wishes to provide materials for display on the video monitors at an IWWC meeting where such monitors are being used to videoconference the meetings must email the materials no later than 10 AM on the day of the meeting. All materials must be contained in a single attachment to the email. Materials received after the 10 AM deadline will not be accepted for display. Display of the materials is subject to all other rules and procedures of the IWWC. Zip drive, memory sticks and other data storage devices will not be accepted. d. 65, 79 and 87 Barkhamsted Road – C. McGee – Conducting a Regulated Activity without a valid IWWC Permit. 7. Commissioner Reports and Correspondence 8. Other Correspondence 9. Adjourn
Page 3
1 MEETING MINUTES Town of Granby Inland Wetlands and Watercourses Commission Wednesday, June 10, 2026, at 7:00 pm PRESENT: Nick Dethlefsen, Barbara Schmitt, David Tolli, Susan Okie, Fred Jones, and Vickie Dirienzo ALSO PRESENT: IWWC Agent Kate Bednaz (Zoom) and Land Use Coordinator Renee Deltenre 1. Call to Order Acting Chair S. Okie called the meeting to order at 7:00 p.m. 2. Action on the May 13, 2026, Meeting Minutes ON A MOTION by V. Dirienzo seconded by F. Jones, the Commission voted 5-0-1 to approve the May 13, 2026, minutes as presented. D. Tolli abstained. 3. Public Hearings a. 199 Broad Hill Road – T. Kurnicki – Permit request to construct a single-family home with associated site improvements within a regulated area. The opening of this hearing has been postponed to the next regular meeting on 7/8/26. 4. Permit Requests a. 94 Quarry Road – J. Fort – Permit request to place a 12’ x 28’ prefabricated garage on crushed stone within a regulated area. Applicant and property owner James Fort was present to discuss the application. He is seeking permission to place a 12’x28’ prefabricated garage on a 14’x30’ crushed stone base with underground electrical within an existing lawn area. The permit request also includes the removal of an existing shed, and K. Bednaz met with the applicant on-site to discuss the project. Since the entire property is a mapped wetland, revisions were made to the application to increase erosion and sedimentation control measures and address some minor changes/recommendations. The application was received and continued to the next regular meeting. b. 37 Hartford Avenue – F. Devine – Permit application for regulated activities in connection with the development of a 16-unit apartment building and associated site improvements. Applicant Forrest Devine and Professional Engineer Rebecca Li were present to discuss the application. The applicant is seeking to construct a 16-unit apartment complex on the existing foundation, which will consist of four 1-bedroom units and twelve 2-bedroom units. The subject property is approximately 111,198 square feet and located within the 100-foot wetland upland review area and 200-foot watercourse upland review area (Salmon Brook tributary). Site improvements include, but are not limited to, parking, utilities, stormwater management, site grading, landscaping, and lighting. Proposed disturbance within the 200- foot upland review area is 10,145 square feet and proposed disturbance within the 100-foot upland review area is 4,642 square feet. R. Li provided an overview of the plans, including erosion and sedimentation control measures, site grading and drainage, septic design, etc. Perk testing has been conducted, and the proposed GST septic system servicing approximately 3,700 GPD will be located in front of the building, parallel to Hartford
Page 4
2 Avenue. F. Devine provided background pertaining to the availability and potential of installing a sewer lateral, which is not a feasible alternative. The Commission discussed the proposed septic system, requested documentation pertaining to feasible and prudent alternatives, had recommendations to the planting plan, etc. ON A MOTION by V. Dirienzo seconded by D. Tolli, the Commission voted 6-0-0 to receive the application and schedule a public hearing for the next regular meeting on 7/8/26 at 7:00 p.m. due to public interest and impact. c. 86 Case Street – J. Vosburgh – Permit request to construct a single-family home with associated site improvements within a regulated area. Applicant Jonathan Vosburgh and Professional Engineer Guy Hesketh were present to discuss the application. The applicant is seeking to construct a new single-family home, approximately 2,500 square feet in size with an attached garage, pool and patio. There is an existing man-made pond that was constructed over 30 years ago, and majority of the site is located within the 200-foot upland review area. Soil Scientist Ian Cole was hired to conduct a wetland delineation, and his report has been provided. G. Hesketh provided a thorough overview of the plans, including erosion and sedimentation control measures, site grading and drainage, septic design, etc. Perk testing has been conducted, and the proposed septic system will be located within the northeast corner of the site utilizing a pre-cast concrete pump station. J. Vosburgh provided a brief history of the site, explaining how the wetlands have changed over time and where fill was deposited during the creation of the farm pond. K. Bednaz expressed concerns with hydrology and the wetland delineation due to the placement of fill overtime and will meet Soil Scientist Ian Cole on site tomorrow to learn how the delineation was conducted. ON A MOTION by V. Dirienzo seconded by B. Schmitt, the Commission voted 6-0-0 to delegate the application to the IWWC Agent for review and approval, as long as the wetland delineation is found to be the same during a site inspection on 6/11/26 by the IWWC Agent. 5. Agent Report and Correspondence a. Update re: 142R and 186 Case Street – M. Reale c/o Scottinaleece, LLC – Conducting a Regulated Activity without a valid IWWC Permit. Property owner Matt Reale was in attendance to provide an update. Soil Scientist David Lord has finalized the wetland delineation around/within the dam area; however, the design of the dam is not complete. No documentation has been provided to the Commission to date and K. Bednaz noted that civil action will be brought against the property owner if no progress is made. ON A MOTION by F. Jones seconded by V. Dirienzo, the Commission voted 6-0-0 to require the submittal of the existing conditions plan for the entire site to be submitted in advance of the next meeting. b. 9 Laurel Drive – V. Rich – RFR to install a ground-mount solar array within a regulated area (retroactive request). Nonregulated Use Determination 5-21-26. K. Bednaz informed the Commission of a recent violation at 7 Laurel Drive, which includes the placement of a prefabricated shed, split rail fencing and underground drainage piping within a regulated area. An Enforcement Order will be issued in advance of the next regular meeting.
Page 5
3 A Notice of Violation was issued on 5/28/26 to the owner of 65, 79 and 87 Barkhamsted Road for the stockpiling of vehicles and various materials within the upland review area of the West Branch of Salmon Brook. K. Bednaz also informed the Commission of a request from Station 280 to reduce the required understory plantings by twenty-five percent. 6. Commissioner Reports and Correspondence None 7. Adjourn ON A MOTION by V. Dirienzo seconded by F. Jones, the Commission voted 6-0-0 to adjourn the meeting at 8:16 p.m. Respectfully submitted, Renee Deltenre Land Use Coordinator
Page 6
Page 7
TOWN OF GRANBY Incorporated 1786 15 North Granby Road Granby, Connecticut 06035-2102 July 8, 2026 James Fort 94 Quarry Road Granby, CT 06035 RE: 94 Quarry Road – J. Fort – Permit request to place a 12’ x 28’ prefabricated garage on crushed stone within a regulated area. Dear Mr. Fort: Please be advised that on July 8, 2026, the Inland Wetlands and Watercourses Commission (IWWC) Agent approved the subject application in accordance with the application and supporting documentation received to date. The following are the conditions of this approval. 1. Permit includes the installation of underground conduit for future electrical to the shed directly from the house and removal of the existing 96 sq. ft. shed, as indicated in email correspondence. 2. The Office of Community Development shall be notified at least 48 hours prior to the start of any construction activities. 3. Town staff shall inspect installed erosion controls prior to the start of any work that results in earth disturbance activities, this includes, but is not limited to, grubbing and stump removal. 4. All work shall be in conformance with the approval and application materials as submitted for this Permit Approval. Any modifications to the approved plans must be reviewed and approved by the Granby Inland Wetlands and Watercourses Commission or their designated Agent. 5. No materials may be deposited outside of the work area, on the project site, without written approval from the IWWC or their designated Agent. 6. Erosion controls shall be maintained until the site has achieved permanent stabilization. Permanent stabilization is defined as 70% permanent vegetation covering over 90% of the area. A stockpile of erosion controls shall remain on site to prepare controls as necessary. The IWWC shall be notified in writing at least 48 hours in advance of erosion controls being removed. 7. Excavated soil shall not be brought off-property without the notification and approval of the Office of Community Development. The applicant shall supply the destination in writing for any excavated soil removed from the property. 8. This permit is valid for a period of 5 years from the date of issuance. 9. Upon completion of construction and site stabilization, the IWWC shall be notified in writing that work is complete, and a final inspection may be completed at that time. If you have any questions, please call the Office of Community Development at your earliest convenience. Sincerely, John Laudati Granby IWWC Chairman
Page 8
Outlook
Re: 94 Quarry - Detached Garage
From Granby Wetlands Agent <wetlandsagent@granby-ct.gov>
Date Mon 6/8/2026 3:58 PM
To jimhfort@gmail.com <jimhfort@gmail.com>
Cc Abigail Kenyon <akenyon@granby-ct.gov>; Renee Deltenre <RDeltenre@granby-ct.gov>
2 attachments (4 MB)
94QuarryShedAerial2026.pdf; 94 Quarry Road Garage Application.pdf;
Hi James,
Thank you for taking the time to answer my questions and layout the location of the garage. Per our conversation and my site visit, I
have attached the modified figures for you to review and confirm if the work is properly depicted. The garage footprint was revised
to show the additional 1-foot of crushed stone that will surround the structure. I have also revised the barrier erosion control to go a
bit father due to the wetlands behind the garage and to include the stockpile, unless you can tarp the entire pile, only if it can be
removed within a short time, noted on the figure. If so, we will include these figures in your application.
When responding to this email, please include the information in narrative form to be included in your application.
1. Where will extra soil be deposited? If within the existing lawn area, it will need to be immediately stabilized with seed and a
thick mulch. As discussed, these are small areas.
2. Please provide a narrative regarding your existing sheds. I have marked one with a blue "x" and the other with a yellow "x".
Please describe which will stay, which will go, and what will you do with the space once the shed is removed.
3. Will there be a ramp to connect the garage to the pavement?
4. What will the shed be placed onto? I believe you said 5" of stone.
Due to your proximity to the wetlands and the fact that you are in mapped wetlands, your application needs to be reviewed and
approved by the IWWC. Your application will go to the IWWC meeting this Wednesday at Town Hall, it starts at 7pm feel free to
attend in person or via zoom. If not, I can review your application to the IWWC. Your application will be received this Wednesday and
can be acted upon/approved at their next regularly scheduled meeting on July 10th.
Looking to tighten up the application and present the information to them this Wednesday evening. As always, please contact me
with any questions or comments.
SINCERELY,
THE GRANBY INLAND WETLANDS AGENT
From: Renee Deltenre <RDeltenre@granby-ct.gov>
Sent: Tuesday, May 26, 2026 11:25 AM
To: Granby Wetlands Agent <wetlandsagent@granby-ct.gov>
Subject: 94 Quarry - Detached Garage
Morning Kate,
We received the attached application on Friday. The property owner is looking to place a prefabricated garage on crushed stone within a wetland.
Thank you,
Renee
Renee DeltenrePage 9
Page 10
94 Quarry Road - Shed Locations Ganby, CT - Inland Wetlands Application 2026 Legend 94 Quarry Rd 80 ft N➤➤ N X X
Page 11
TOWN OF GRANBY
Office of Community Development, Inland Wetlands and Watercourses Commission
Telephone: (860) 844-5318, www.granby-ct.gov
App
lication for Inland Wetlands & Watercourses Activity
Application For: Permit Extension Modification (Existing Permit/Application #): __________________________
Wetlands Map Amend. Request for Review Other:
Property Location and Nearest Intersection:
Size of Parcel:_________ Zone: ________ Map/Lot: ____________ Current Use: ___________________________
Applicant’s Name:
Complete Address:
Daytime Phone: Evening Phone: Fax:
Email:
Owner’s Name:
If the owner is a corporation, or other non-individual entity, include the primary contact information
Complete Address:
Phone Daytime Phone: Evening Phone: Fax:
Applicant’s Representative:
Complete Address:
Daytime Phone: Evening Phone: Fax:
*****
**************************PLEASE ATTACH ADDITIONAL SHEET IF NECESSARY**************************************
Project Name and Brief Description (i.e. residential, agricultural, commercial, number of lots, etc.):
Is any portion of the property located within 500 feet of an adjoining municipality?
Wetlands Located on Property (in square feet (sq. ft.)): Wetlands to be impacted (sq. ft.):
Watercourses Located on Property? Name or Type of Watercourse:
Are Proposed Activities Located within the 100-Year Floodplain? Floodway?
Are there slopes with grades in excess of 15% located on the property?
Do Proposed Activities Require Review by the PZC?
*********SEE APPLICATION CHECKLIST ON BACK for MINIMUM APPLICATION REQUIREMENTS**********
The applicant understands that this application is to be considered complete only when all information and documents required by
the Commission have been submitted. The undersigned warrants the truth of all statements contained herein and in all supporting
documents according to the best of his/her knowledge and belief. Permission is granted to the Town of Granby, Inland Wetlands &
Watercourses Commission, and its agent (s) to inspect the subject land, at reasonable times, during the pendency of an application
and for the life of the permit.
Applicant’s Signature: Date:
Owner’s Signature: Date:
FOR OFFICE USE
Application #: Date Submitted:
Fee amt./Check or Cash: Date of Receipt:
Agent Ruling: Date Approved/Denied:
See Reverse Side for Conditions of Approval or Reason for Denial
86 Case Street
Jonathan Vosburgh
86 Case Street
R4A
2.92 Ac.
H-10/66/25
Vacant
860-916-7495
860-916-7495
vosburghjon@gmail.com
Joseph A Bazyk
F. A. Hesketh & Assoc., Inc.
6 Creamery Brook, East Granby, CT 06026
860-653-8000
Consruction of single-family home with attached garage, pool, patio, septic system and utilities.
No
0.0
No
No
No, site plan approval only
Yes
16,740
Pond and drainage ditch from pond outlet.
Only on banks of man-made pond.
85 Case Street, West Granby, CT 06090 Page 12
1060.3 1061.0 1052.5 1052.5 1061.5 1061.0 1060.70 1061.0 1066.73 1066.73 1065.80 1065.80 1058.5 1061.0 1060.48 1060.00 1059.65 1059.41 1059.65 1059.41 1059.5 1061.0 1061.0 1061.5 1058.0 1061.0 1057.51056.5 SOIL PROFILE PERC TEST RESULTS TEST PIT I.D. PT-1 = 267 MIN./18 IN. = 14.83 MIN./IN. PT-2 = 259 MIN./22 IN. = 11.77 MIN./IN. 100.00 194
Page 13
From: Granby Wetlands Agent To: Jon Vosburgh Cc: Abigail Kenyon; Renee Deltenre; Cassidy Davidson; Guy Hesketh Subject: Re: 86 Case Rd Wetlands resubmission Date: Wednesday, July 1, 2026 5:44:17 PM Thank you, Jon. To confirm there will be no machinery used to prepare the base for the pavers? If machinery is intended, please narrate the path of access. Ty Kate Get Outlook for iOS From: Jon Vosburgh <vosburghjon@gmail.com> Sent: Tuesday, 30 June 2026 13:06:58 To: Granby Wetlands Agent <wetlandsagent@granby-ct.gov> Cc: Abigail Kenyon <akenyon@granby-ct.gov>; Renee Deltenre <RDeltenre@granby-ct.gov>; Cassidy Davidson <CassidyRoswelldev@outlook.com>; Guy Hesketh <ghesketh@fahesketh.com> Subject: Re: 86 Case Rd Wetlands resubmission CAUTION: This email originated from outside of the organization. Do not click links or open attachments unless you recognize the sender and know the content is safe. Kate, thank you for the clarification. We will make the changes and have them back to the town sometime tomorrow. Below is the narrative that you asked me to outline concerning the walks and patio by the pond. As part of this application we are including walkways and a small patio on the edge of the pond as shown on the revised plan. We are proposing approximately 36 inch wide walks and approximately 8' x 10’ patio. The surface of the walks and patio will be hand laid concrete pavers. We acknowledge that any further disturbance will require the appropriate erosion control. Please let me know if this is sufficient for the final submittal. Thank you very much On Jun 30, 2026, at 2:47 PM, Granby Wetlands Agent <wetlandsagent@granby-ct.gov> wrote: The incorrect boundary Get Outlook for iOS From: Jon Vosburgh <vosburghjon@gmail.com> Sent: Tuesday, 30 June 2026 12:20:13 To: Granby Wetlands Agent <wetlandsagent@granby-ct.gov> Cc: Abigail Kenyon <akenyon@granby-ct.gov>; Renee Deltenre <RDeltenre@granby-ct.gov>; Cassidy Davidson <CassidyRoswelldev@outlook.com>; Guy Hesketh <ghesketh@fahesketh.com> Subject: Re: 86 Case Rd Wetlands resubmission CAUTION: This email originated from outside of the organization. Do not click links or open attachments unless you recognize the sender and know the content is safe. Kate are you talking about the Wetlands flagging that is shown within our new boundary. We can take that off. is there anything else? On Jun 30, 2026, at 12:11 PM, Granby Wetlands Agent <wetlandsagent@granby-ct.gov> wrote: Thank you, Jon, The plan has wetland boundaries is a bit confusing and not correct. Please take those boundaries off and resubmit. We will need paper copies for next Wednesday's meeting. The IWWC will need to make the approval as there is direct disturbance to the wetlands with this layout. I anticipate they will vote for an approval at next Wednesday's meeting. SINCERELY, THE GRANBY INLAND WETLANDS AGENT <image.png> From: Jon Vosburgh <vosburghjon@gmail.com> Sent: Monday, June 29, 2026 9:07 AM To: Abigail Kenyon <akenyon@granby-ct.gov>; Granby Wetlands Agent <wetlandsagent@granby-ct.gov>; Renee Deltenre <RDeltenre@granby-ct.gov>; Cassidy Davidson <CassidyRoswelldev@outlook.com> Subject: 86 Case Rd Wetlands resubmission CAUTION: This email originated from outside of the organization. Do not click links or open attachments unless you recognize the sender and know the content is safe. Hi All, attached is the revised plans reflecting Kate's requirements as discussed in the field with myself and Ian Cole. Please review and let me know if there's anything else that is needed. Do I need to deliver paper copies for the commission prior to the next public hearing on July 8th? If so please refresh my memory on how many and what size copies you need. Thank you very much Jonathan Vosburgh Roswell Development LLC 125 Lasalle Rd Suite 202 West Hartford CT 06107
Page 14
TOWN OF GRANBY Incorporated 1786 15 North Granby Road Granby, Connecticut 06035-2102 1 July 8, 2026 Jonathan Vosburgh 6 Brighton Park Way Bloomfield, CT 06002 RE: 86 Case Street – J. Vosburgh – Permit request to construct a single-family home with associated site improvements within a regulated area. Dear Mr. Vosburgh: Please be advised that on July 8, 2026, the Inland Wetlands and Watercourses Commission (IWWC) Agent approved the subject application in accordance with the application and supporting documentation received to date. The following are the conditions of this approval. 1. Notification Requirements a. The Office of Community Development shall be notified at least 48 hours prior to the start of any activities; b. When barrier erosion controls have been installed prior to earth disturbance activities; and c. Upon completion of project activities. 2. Municipal Inspection a. Town staff shall inspect installed erosion controls prior to the start of work that results in earth disturbance activities, this includes, but is not limited to, grubbing and stump removal. b. Standard inspections of the approved improvements shall be made throughout active construction and upon final stabilization of exposed soils to ensure regulatory compliance and protection of wetland resource areas. 3. Prior to the start of work, the applicant shall submit a bond in the amount of $500 to the Town of Granby for payments made to the Town Wetlands Officer for monitoring the development for compliance with this approval. Should the costs exceed this amount the applicant will be billed for the difference. Any funds not used for the project will be remitted to the applicant at the conclusion of the project. As used in this condition, the term Town Wetlands Officer includes any person or firm designated by the Director of Community Development for the purposes of monitoring the development activities to assure compliance with this approval and the IWWC Regulations. 4. All work shall be in conformance with the approval and application materials as submitted for this Permit Approval. Any modifications to the approved plans must be reviewed and approved by the Granby Inland Wetlands and Watercourses Commission or their designated Agent. 5. Erosion controls shall be maintained until the site has achieved permanent stabilization. Permanent stabilization is defined as 70% permanent vegetation covering over 90% of the area. A stockpile of erosion controls shall remain on site to prepare controls as necessary. The IWWC shall be notified in writing at least 48 hours in advance of erosion controls being removed. 6. Excavated soil shall not be brought off-property without the notification and approval of the Office of Community Development. The applicant shall supply the destination in writing for any excavated soil removed from the property.
Page 15
2 7. Only clean fill, free of invasive species, shall be brought on-site. Utilizing on-site fill will reduce, if not eliminate the potential for the introduction and potential colonization of new invasive species into this area of the watershed. 8. This permit is valid for a period of 5 years from the date of issuance. Please provide a Mylar copy of the approved maps to the Office of Community Development for the signature of the Inland Wetlands and Watercourses Commission’s Chairman at your earliest convenience. Once the approved Mylar is signed by the Commission’s Chairman, you will need to file it in the office of the Town Clerk. If you have any questions, please contact the Office of Community Development at your earliest convenience. Sincerely, John Laudati Granby IWWC Chairman
Page 16
Page 17
Page 18
Page 19
Page 20
Page 21
Page 22
Page 23
JACKSON ENVIRONMENTAL, LLC
- Environmental and Soil Consultants -
289 High Road, Kensington, Connecticut 06037
Telephone and Fax: 860-224-4063
March 18, 2025
Harry and Susan Werner
20 Godard Road
North Granby, CT 06060
Re: Soils and Wetlands / Watercourse Delineation Report
#5 Godard Road, North Granby, CT
JE Project No. 25-06
Dear Mr. and Mrs. Werner:
The wetlands and watercourses within the northern section of an approximate 7.4-acre parcel of
land identified as 5 Godard Road, North Granby were delineated on March 15, 2025. The subject
property is shown on the December 2007 Property Survey Showing Conservation Easements to
be Granted to Granby Land Trust, Inc., Property Owned by Susan H. Werner, 5, 20 & 21 Godard
Road, Granby Conn., prepared by Harry C. Cotton & Associates. The wetland / watercourse
boundary delineations were limited to the vicinity of a proposed residential development in the
northern section of the parcel.
Published Soil Map Units
The Web Soil Survey1 identified the following map unit for the #5 Godard Road Property:
Gloucester gravelly sandy loam, 8 to 15% slope (57C)
The U.S. Department of Agriculture, Natural Resources Conservation Service describes the
Gloucester soil series as “very deep, somewhat-excessively-drained-soils formed in sandy glacial
till sediments. They are on nearly level to very steep moraines, hills, and ridges. Slope ranges
from 0 to 50 percent.”2
Fluvaquents-Udifluvents (109)
Fluvaquents are poorly-drained soils composed of sandy and/or loamy alluvium. This soil type is
on flood plains and stream valleys. Udifluvents have a moderately-well-drained to well-drained
drainage classification and are found on flood plains and stream valleys. The parent material for
the soil is sandy and/or loamy alluvium. Alluvial soils are regulated as wetlands in Connecticut.
1 The Web Soil Survey. USDA, Natural Resources Conservation Service. http://websoilsurvey.nrcs.usda.gov
2 https://soilseries.sc.egov.usda.gov/OSD_Docs/G/GLOUCESTER.html
Page 24
Harry & Susan Werner JACKSON March 18, 2025 ENVIRONMENTAL, LLC Field Notes The uplands soils within the project area were consistent with the Gloucester gravelly sandy loam soil map unit. The soil is suitable for the location and design of subsurface sewage treatment and disposal systems. A narrow watercourse, tributary to the East Branch of the Salmon Brook, flows in a general northerly direction within the subject property. Wetland / watercourse boundary flags ‘A-1’ through ‘A-27 were placed along the along the western side of the watercourse channel. The flags extend from the vicinity of the northern property boundary to a concrete weir within the watercourse channel located adjacent to the Frog Pond. The A-series flags bordered alluvial terraces composed of Fluvaquents and poorly-drained soils exhibiting groundwater seeps or drainageways. Wetland boundary flags ‘B-1’ through ‘B-11’ were placed around the steep side-slopes bordering the Frog Pond. Wetland / watercourse boundary flags ‘1B-1’ through ‘1B-6’ were placed around poorly-drained soils within an elliptical depression located down-slope from the pond outlet. The wetland drained to a an approx. 8 to 12-inch reinforced concrete pipe beneath Godard Road. Please contact me at (860) 213-3152 with any questions or comments regarding this report. Sincerely, JACKSON ENVIRONMENTAL, LLC William A. Jackson, R.S., L.E.P. Registered Soil Scientist
Page 25
Page 26
Page 27
Page 28
Page 29
Page 30
KEY MAP Harmony Hill Road 8 Lot Residential Subdivision Granby, Connecticut Map D-43 Block 21 Lot 56 Harmony Hill Farms S:\Acad\2026 Civil 3D\2026-028 Roswell - Harmony Hill Rd., Granby\Russo Drawings\2026-028.dwg, 1:1
Page 31
KEY MAP S:\Acad\2026 Civil 3D\2026-028 Roswell - Harmony Hill Rd., Granby\Russo Drawings\2026-028.dwg, 1:1
Page 32
KEY MAP S:\Acad\2026 Civil 3D\2026-028 Roswell - Harmony Hill Rd., Granby\Russo Drawings\2026-028.dwg, 1:1
Page 33
SPECIFICATIONS Time Of Year Site Preparation Seed Selection Seedbed Preparation Seed Application Mulching MAINTENANCE (PS) SPECIFICATIONS Materials Types of Mulches 1. Hay: 2. Straw: 3. Cellulose Fiber: Tackifiers Emulsified asphalts are specifically prohibited for use as tackifiers due to their potential for causing water pollution following its application. Nettings Site Preparation Application Timing: Mulch For Seed Spreading: Anchoring: MAINTENANCE (MS) SPECIFICATIONS Site Preparation Seedbed Preparation Seeding Mulching MAINTENANCE (TS) GEOTEXTILE SILT FENCE (GSF) ANTI-TRACKING PAD DETAIL (CE) SPECIFICATIONS Mechanical Sweeping Water Non-Asphaltic Soil Tackifier MAINTENANCE (DC) PAVED DRIVEWAY DETAIL CB GRATE INLET PROTECTION (SILT SACK) DRYWELL DETAIL S:\Acad\2026 Civil 3D\2026-028 Roswell - Harmony Hill Rd., Granby\Russo Drawings\2026-028.dwg, 1:1
Page 34
Page 35
Page 36
Page 37
Page 38
Page 39
Page 40
TOWN OF GRANBY Public Hearing Inland Wetlands and Watercourses Commission (IWWC) There will be a public hearing conducted by the IWWC on Wednesday, June 10, 2026, at 7:00 p.m. in the Granby Town Hall Meeting Room, 15 North Granby Road to hear and consider the following item: 199 Broad Hill Road – T. Kurnicki – Permit request to construct a single-family home with associated site improvements within a regulated area. At the hearing interested persons may appear and written communications will be received. Copies of the proposal are on file in the Community Development Office. To the Hartford Courant: Please publish on the following dates: May 29, 2026, and June 5, 2026, in the Connecticut Section Zone 5 Please send billing to the Town of Granby 15 North Granby Road, Granby, CT 06035 Approved as written - No affidavit of publication to be submitted. Account # 113533 Renee Deltenre 860-844-5319
Page 41
Page 42
Page 43
Page 44
Wetland/Watercourse Delineation Memo Delineation of 199 Broad Hill Road Granby, CT June 2026 1. INTRODUCTION At the request of Thomas Kurnicki , EarthView Design’s professional soil scientist conducted a field investigation at 199 Broad Hill Road in the town of Granby, Connecticut (the site). The purpose of the field investigation was to document and delineate wetlands and watercourses, if present. The field investigation was conducted on June 6, 2026. 2. RESULTS In the area of investigation (the site) , the Ordinary High Water ( OHW) elevation associated with one presumed perennial watercourse was demarcated in the field. Additionally, three State- and Federally- regulated wetlands were demarcated in the field. The perennial watercourse may be intermittent, as the site assessment was not conducted in the driest time of the year. If the watercourse is intermittent, then the wetlands delineated at the site would be State-only regulated. Investigations north of Broad Hill Road did not reveal wetland soils or wetland vegetation. The soils in this area consisted of sandy, roadside fill with asphalt pieces and small rocks best classified as human-altered Udorthents. Soil samples along the roadway met refusal at about 2 inches deep. Vegetation observed in this area was deer tongue grass (Dichanthelium clandestinum ), broad dock (Rumex obtusifolius ), mugwort (Artemisia vulgaris), Virginia creeper (Parthenocissus quinquefolia), and Meadow hawkweed (Hieracium caespitosum). See the photographs in Appendix A.
Page 45
3. DETAILED RESOURCE DESCRIPTIONS Unnamed perennial watercourse : An unnamed perennial watercourse flows from the southwest to the northeast through the western portion of the site. Flows were consistent, but the depth was less than 1 inch, so this stream may be intermittent at the driest times of the year. At the time of the investigation the stream was less than 1-inch deep, flowing downhill into the wetlands described below. The stream channel was about 2-6 feet wide, mostly shaded, and had approximately 2-6 inch high banks. Both banks were vegetated with marsh fern ( Thelypteris palustris ), poison ivy (Toxicodendron radicans ), interrupted fern (Osmunda claytoniana ), jewelweed ( Impatiens capensis ), Northern spicebush (Lindera benzoin), and Jack-in-the-pulpit (Arisaema triphyllum). The stream substrate was mostly sandy with small rocks. This stream was channelized flowing downhill, then becomes diffuse and loses its channel in the wetlands, then is channelized again as it exits the wetlands. Wetland A/B: Wetland A/B is a Palustrine Emergent/Palustrine Scrub- shrub wetland (PEM/PSS) associated with the unnamed perennial watercourse. Vegetation in Wetland A/B includes red maple (Acer rubrum) trees (on the edge) ; silky dogwood (Cornus amomum), Northern spicebush (Lindera benzoin), multiflora rose (Rosa multiflora), and speckled alder (Alnus incana) shrubs; sensitive fern (Onoclea sensibilis), marsh fern, jewelweed, cinnamon fern ( Osmundastrum cinnamomeum ), hop sedge (Carex lupuliformis), and blue flag iris (Iris versicolor) in the herbaceous layer; and poison ivy and fox grape (vitis labrusca) in the liana layer. The soil in this wetland is mapped as Natural Resource Conservation Service (NRCS) Hollis-Chatfield-rock outcrop complex, 15 to 45 percent slopes. However, the soil observed in the wetland is a very poorly drained Leicester fine sandy loam. Wetland C: Wetland C is a Palustrine Emergent wetland (PEM) located on the western side of the perennial watercourse on the southwestern portion of the property. This wetland is sparsely vegetated with jewelweed and has a hillside seep adding to its hydrology. The soil in this wetland is mapped as NRCS Gloucester gravely sandy loam, 15 to 35 percent slopes, extremely stony. However, the soil observed in the wetland is a very poorly drained Leicester fine sandy loam. Wetland D: Wetland D is a Palustrine Emergent wetland (PEM) located on the western side of the perennial watercourse, uphill from Wetland C, on the southwestern portion of the property. This wetland is sparsely vegetated with jewelweed, jack-in-the-pulpit, and marginal wood fern ( Dryopteris marginalis) and has a hillside seep adding to its hydrology. The soil in this wetland is mapped as NRCS Gloucester gravely sandy loam, 15 to 35 percent slopes, extremely stony. However, the soil observed in the wetland is a very poorly drained Leicester fine sandy loam. 4. NRCS MAPPED SOILS Only those soils found on the project area are described below. See Appendix B for soil mapping. Hollis-Chatfield-rock outcrop complex, 15 to 45 percent slopes: The Hollis component makes up 35 percent of the map unit. Slopes are 15 to 45 percent. This component is on bedrock controlled hills, bedrock controlled ridges, and uplands. The parent material consists of loamy melt -out till derived from granite and/or schist and/or gneiss. The natural drainage class is somewhat excessively drained. This soil is not flooded. It is not ponded. This soil does not meet hydric criteria. The Chatfield component makes up 30 percent of the map unit. Slopes are 15 to 45 percent. This component is on bedrock controlled hills, bedrock controlled ridges, and uplands. The parent material consists of coarse-loamy melt-out till derived from granite and/or schist and/or gneiss. The natural drainage class is well drained. This soil does not meet hydric criteria.
Page 46
Leicester fine sandy loam: The Leicester component makes up 80 percent of the map unit. Slopes are 0 to 5 percent. This component is on depressions on uplands, drainageways on uplands. The parent material consists of coarse-loamy melt-out till derived from granite and/or schist and/or gneiss. The natural drainage class is poorly drained. This soil meets hydric criteria. Gloucester gravely sandy loam, 15 to 35 percent slopes, extremely stony: The Gloucester component makes up 80 percent of the map unit. Slopes are 15 to 35 percent. This component is on hills on uplands. The parent material consists of sandy and gravelly melt -out till derived from granite and/or schist and/or gneiss. The natural drainage class is somewhat excessively drained. This soil is not flooded. It is not ponded. This soil does not meet hydric criteria.
Page 47
APPENDIX A: PHOTOGRAPHS Upland area north of the property across Broad Hill Road looking southwest Upland area north of the property across Broad Hill Road looking northeast
Page 48
Watercourse looking southwest Watercourse looking southeast
Page 49
Wetland A/B looking northeast Wetland A/B looking northeast
Page 50
Wetland C looking northwest Wetland D looking south
Page 51
APPENDIX B: WEB SOIL SURVEY
Page 52
Soil Map—State of Connecticut, Western Part Natural Resources Conservation Service Web Soil Survey National Cooperative Soil Survey 6/5/2026 Page 1 of 3 4646920 4646980 4647040 4647100 4647160 4647220 4647280 4646920 4646980 4647040 4647100 4647160 4647220 4647280 676900 676960 677020 677080 677140 677200 677260 677320 677380 677440 676900 676960 677020 677080 677140 677200 677260 677320 677380 677440 41° 57' 28'' N 72° 51' 57'' W 41° 57' 28'' N 72° 51' 30'' W 41° 57' 15'' N 72° 51' 57'' W 41° 57' 15'' N 72° 51' 30'' WN Map projection: Web Mercator Corner coordinates: WGS84 Edge tics: UTM Zone 18N WGS84 0 100 200 400 600 Feet 0 40 80 160 240 Meters Map Scale: 1:2,780 if printed on A landscape (11" x 8.5") sheet. Soil Map may not be valid at this scale.
Page 53
MAP LEGEND MAP INFORMATION Area of Interest (AOI) Area of Interest (AOI) Soils Soil Map Unit Polygons Soil Map Unit Lines Soil Map Unit Points Special Point Features Blowout Borrow Pit Clay Spot Closed Depression Gravel Pit Gravelly Spot Landfill Lava Flow Marsh or swamp Mine or Quarry Miscellaneous Water Perennial Water Rock Outcrop Saline Spot Sandy Spot Severely Eroded Spot Sinkhole Slide or Slip Sodic Spot Spoil Area Stony Spot Very Stony Spot Wet Spot Other Special Line Features Water Features Streams and Canals Transportation Rails Interstate Highways US Routes Major Roads Local Roads Background Aerial Photography The soil surveys that comprise your AOI were mapped at 1:12,000. Warning: Soil Map may not be valid at this scale. Enlargement of maps beyond the scale of mapping can cause misunderstanding of the detail of mapping and accuracy of soil line placement. The maps do not show the small areas of contrasting soils that could have been shown at a more detailed scale. Please rely on the bar scale on each map sheet for map measurements. Source of Map: Natural Resources Conservation Service Web Soil Survey URL: Coordinate System: Web Mercator (EPSG:3857) Maps from the Web Soil Survey are based on the Web Mercator projection, which preserves direction and shape but distorts distance and area. A projection that preserves area, such as the Albers equal-area conic projection, should be used if more accurate calculations of distance or area are required. This product is generated from the USDA-NRCS certified data as of the version date(s) listed below. Soil Survey Area: State of Connecticut, Western Part Survey Area Data: Version 6, Sep 16, 2025 Soil map units are labeled (as space allows) for map scales 1:50,000 or larger. Date(s) aerial images were photographed: Jun 14, 2022—Oct 6, 2022 The orthophoto or other base map on which the soil lines were compiled and digitized probably differs from the background imagery displayed on these maps. As a result, some minor shifting of map unit boundaries may be evident. Soil Map—State of Connecticut, Western Part Natural Resources Conservation Service Web Soil Survey National Cooperative Soil Survey 6/5/2026 Page 2 of 3
Page 54
Map Unit Legend Map Unit Symbol Map Unit Name Acres in AOI Percent of AOI 38C Hinckley loamy sand, 3 to 15 percent slopes 1.4 3.6% 51B Sutton fine sandy loam, 0 to 8 percent slopes, very stony 1.1 2.8% 57B Gloucester gravelly sandy loam, 3 to 8 percent slopes 0.5 1.3% 59D Gloucester gravelly sandy loam, 15 to 35 percent slopes, extremely stony 6.0 15.2% 62D Canton and Charlton fine sandy loams, 15 to 35 percent slopes, extremely stony 1.3 3.2% 73E Charlton-Chatfield complex, 15 to 45 percent slopes, very rocky 9.2 23.0% 75C Hollis-Chatfield-Rock outcrop complex, 3 to 15 percent slopes 4.0 10.0% 75E Hollis-Chatfield-Rock outcrop complex, 15 to 45 percent slopes 8.8 22.1% 109 Fluvaquents-Udifluvents complex, frequently flooded 7.5 18.8% Totals for Area of Interest 39.9 100.0% Soil Map—State of Connecticut, Western Part Natural Resources Conservation Service Web Soil Survey National Cooperative Soil Survey 6/5/2026 Page 3 of 3
Page 55
Page 56
Page 57
Page 58
Page 59
Page 60
Page 61
Kevin Clark, PEL (860) 844-5318 Town Engineer townengineer@granby-ct.gov Town of Granby 15 North Granby Road Granby, CT 06035 MEMORANDUM Date: July 2, 2026 RE: “Residential Home Concept Plan , prepared for Thomas Kurnicki, 199 Broad Hill Road, Granby, Connecticut, Scale:1”=30’, March 30, 2026, Revised 6/30/26, Barresi Associates, LLC.” Comments: Sheet 2 of 6 : 1. Provide drainage computations. May need a full- sized catch basin rather than a “ Yard Drain,” due to peak runoff. The drainage area is a little over 4 acres. 2. New manhole in the right-of-way to conform to town requirements. Is it possible to use a catch basin and intercept the flow in the shoulder before it drains on the pavement? 3. Do not fill in the right-of-way. Consider using a rip rap slope to steepen the grade. 4. Provide a shoulder for the driveway along the downhill side . Not possible to grade up to the edge of the pavement. 5. Add SL to legend and provide a detail on sheet 5. by: Kevin Clark, PEL, Town Engineer
Page 62
TOWN OF GRANBY Incorporated 1786 15 North Granby Road Granby, Connecticut 06035-2102 1 July 8, 2026 Thomas Kurnicki 1300 22nd Street Apartment #111 San Francisco, CA 94107 RE: 199 Broad Hill Road – T. Kurnicki – Permit request to construct a single-family home with associated site improvements within a regulated area. Dear Mr. Kurnicki: Please be advised that on July 8, 2026, the Inland Wetlands and Watercourses Commission (IWWC) Agent approved the subject application in accordance with the application and supporting documentation received to date. The following are the conditions of this approval. 1. Notification Requirements a. The Office of Community Development shall be notified at least 48 hours prior to the start of any activities; b. When barrier erosion controls have been installed prior to earth disturbance activities; and c. Upon completion of project activities. 2. Municipal Inspection a. Town staff shall inspect installed erosion controls prior to the start of work that results in earth disturbance activities, this includes, but is not limited to, grubbing and stump removal. b. Standard inspections of the approved improvements shall be made throughout active construction and upon final stabilization of exposed soils to ensure regulatory compliance and protection of wetland resource areas. 3. The applicant shall reimburse the Town of Granby for all payments made to the Town Wetlands Officer for monitoring the development for compliance with this approval. The reimbursement rate is $90 per hour for the services of the Town Wetlands Officer. The applicant shall deposit with the Town of Granby the sum of $500 to be applied to the costs as described herein. Should the costs exceed this amount, the applicant will be billed for the difference. Any funds not used for the project will be remitted to the applicant at the conclusion of the project. As used herein, the term Town Wetlands Officer includes any person or firm designated by the Director of Community Development for the purposes of monitoring the development activities to assure compliance with this approval and the IWWC Regulations. 4. All work shall be in conformance with the approval and application materials as submitted for this Permit Approval. Any modifications to the approved plans must be reviewed and approved by the Granby Inland Wetlands and Watercourses Commission or their designated Agent. 5. Erosion controls shall be maintained until the site has achieved permanent stabilization. Permanent stabilization is defined as 70% permanent vegetation covering over 90% of the area. A stockpile of erosion controls shall remain on site to prepare controls as necessary. The IWWC shall be notified in writing at least 48 hours in advance of erosion controls being removed.
Page 63
2 6. Excavated soil shall not be brought off-property without the notification and approval of the Office of Community Development. The applicant shall supply the destination in writing for any excavated soil removed from the property. 7. Only clean fill, free of invasive species, shall be brought on-site. Utilizing on-site fill will reduce, if not eliminate the potential for the introduction and potential colonization of new invasive species into this area of the watershed. 8. This permit is valid for a period of 5 years from the date of issuance. Please provide a Mylar copy of the approved maps to the Office of Community Development for the signature of the Inland Wetlands and Watercourses Commission’s Chairman at your earliest convenience. Once the approved Mylar is signed by the Commission’s Chairman, you will need to file it in the office of the Town Clerk. If you have any questions, please contact the Office of Community Development at your earliest convenience. Sincerely, John Laudati Granby IWWC Chairman
Page 64
TOWN OF GRANBY Public Hearing Inland Wetlands and Watercourses Commission (IWWC) There will be a public hearing conducted by the IWWC on Wednesday, July 8, 2026, at 7:00 p.m. in the Granby Town Hall Meeting Room, 15 North Granby Road to hear and consider the following item: 37 Hartford Avenue – F. Devine – Permit application for regulated activities in connection with the development of a 16-unit apartment building and associated site improvements. At the hearing interested persons may appear and written communications will be received. Copies of the proposal are on file in the Community Development Office. To the Hartford Courant: Please publish on the following dates: June 26, 2026, and July 3, 2026, in the Connecticut Section Zone 5 Please send billing to the Town of Granby 15 North Granby Road, Granby, CT 06035 Approved as written - No affidavit of publication to be submitted. Account # 113533 Renee Deltenre 860-844-5319
Page 65
R LEVESQUE ASSOCIATES, INC. A L AND PL ANNING SERVICES COMPANY 40 School Street, Westfield, MA 01085 p 413.568.0985 · f 413.568.0986 · www.rlaland.com Application for Inland Wetlands & Watercourses Activity Under the Inland Wetlands & Watercourses Act & the Town of Granby Inland Wetlands and Watercourse Regulations Proposed Residential Development Project Location: 37 Hartford Avenue Granby, Connecticut 06035 (Parcel ID: 4254) Submitted To: Town of Granby Inland Wetlands & Watercourses Commission 15 North Granby Road Granby, Connecticut 06035 Applicant: Forrest Devine 129 Lovers Lane Granville, Massachusetts 01034 Property Owner: Howland Partners, LLC 39 Brown Road South Kent, Connecticut 06785 RLA Project File No. 251219 June 1, 2026
Page 66
TABLE OF CONTENTS
SECTION
1. COVER LETTER
2. ADMINISTRATIVE FORMS
2.1 APPLICATION FOR INLAND WETLNDS & WATERCOURSES ACTIVITY
2.2 APPLICATION CHECKLIST
2.3 FEE SCHEDULE
2.4 STATEWIDE INLAND WETLANDS & WATERCOURSES ACTIVITY REPORT FORM
3. PROJECT NARRATIVE
4. WETLAND SCIENTIST / SOIL REPORT
5. FIGURES
5.1 FIGURE 1 – TOPOGRAPHIC MAP
5.2 FIGURE 2 – FEMA FLOODPLAIN MAP
5.3 FIGURE 3 – NRCS SOIL MAP
5.4 FIGURE 4 – NATURAL DIVERSITY DATA BASE
6. ABUTTER NOTIFICATION
6.1 ABUTTER LIST – 100’
6.2 ABUTTER NOTIFICATION LETTER (TO BE PROVIDED UPON CONFIRMATION I F PUBLIC
HEARING IS NECESSARY)
LIST OF APPENDICES
APPENDICES
APPENDIX A: SITE PLAN SET
APPENDIX B: STORMWATER REPORTPage 67
1. COVER LETTER
Page 68
R LEVESQUE ASSOCIATES, INC. 40 School Street, P.O. BOX 640, Westfield, MA 01085 p 413.568.0985 · f 413.568.0986 · www.rlaland.com A L AND PL ANNING SERVICES COMPANY June 1, 2026 John L. Laudati, Chairman Town of Granby Inland Wetlands & Watercourses Commission 15 North Granby Road Granby, Connecticut 06035 RE: Proposed Residential Development 37 Hartford Avenue Granby, Connecticut 06035 (Parcel ID: 4254) RLA Project File No. 251219 Dear Chairman Laudati: On behalf of the applicant, Forrest Devine, please find the requisite number of copies of an Application for Inland Wetlands & Watercourses Activity and associated documentation. The applicant proposes the construction of a multifamily residential development with associated site improvements within the 100’ Upland Review Area to a Wetland and 200’ Upland Review Area to a Watercourse (tributary to “Salmon Brook”). Included within this submission package is the requisite filing fee. As required, a copy of this submittal has been provided electronically via email to the Town of Granby’s staff. We are respectfully requesting to be placed on the Agency’s next available agenda for review . Should you have any questions or comments regarding this filing, please do not hesitate to contact our office at your earliest convenience. Sincerely, R LEVESQUE ASSOCIATES, INC. Ryan Nelson Wetland/Soil Scientist & Project Manager
Page 69
2. ADMINISTRATIVE FORMS 2.1 APPLICATION FOR INLAND WETLNDS & WATERCOURSES ACTIVITY 2.2 APPLICATION CHECKLIST 2.3 FEE SCHEDULE 2.4 STATEWIDE INLAND WETLANDS & WATERCOURSES ACTIVITY REPORT FORM
Page 70
TOWN OF GRANBY
Office of Community Development, Inland Wetlands and Watercourses Commission
Telephone: (860) 844-5318, www.granby-ct.gov
Ap
plication for Inland Wetlands & Watercourses Activity
Application For: Permit Extension Modification (Existing Permit/Application #): __________________________
Wetlands Map Amend. Request for Review Other:
Pr
operty Location and Nearest Intersection:
Size of Parcel:_________ Zone: ________ Map/Lot: ____________ Current Use: ___________________________
Applicant’s Name:
Complete Address:
Daytime Phone: Evening Phone: Fax:
Email:
Ow
ner’s Name:
If the owner is a corporation, or other non-individual entity, include the primary contact information
Complete Address:
Phone Daytime Phone: Evening Phone: Fax:
Ap
plicant’s Representative:
Complete Address:
Daytime Phone: Evening Phone: Fax:
**
*****************************PLEASE ATTACH ADDITIONAL SHEET IF NECESSARY**************************************
Project Name and Brief Description (i.e. residential, agricultural, commercial, number of lots, etc.):
Is any portion of the property located within 500 feet of an adjoining municipality?
Wetlands Located on Property (in square feet (sq. ft.)): Wetlands to be impacted (sq. ft.):
Watercourses Located on Property? Name or Type of Watercourse:
Are Proposed Activities Located within the 100-Year Floodplain? Floodway?
Are there slopes with grades in excess of 15% located on the property?
Do Proposed Activities Require Review by the PZC?
*********SEE APPLICATION CHECKLIST ON BACK for MINIMUM APPLICATION REQUIREMENTS**********
The applicant understands that this application is to be considered complete only when all information and documents required by
the Commission have been submitted. The undersigned warrants the truth of all statements contained herein and in all supporting
documents according to the best of his/her knowledge and belief. Permission is granted to the Town of Granby, Inland Wetlands &
Watercourses Commission, and its agent (s) to inspect the subject land, at reasonable times, during the pendency of an application
and for the life of the permit.
Applicant’s Signature: Date:
Owner’s Signature: Date:
FO
R OFFICE USE
Application #: Date Submitted:
Fee amt./Check or Cash: Date of Receipt:
Agent Ruling: Date Approved/Denied:
Se
e Reverse Side for Conditions of Approval or Reason for Denial
37 Hartford Avenue (Hartford Avenue - Shattuck Avenue)
111,198 SF COCE 4254 Vacant
129 Lovers Lane, Granville, MA 01034
(413) 478-9691 (413) 478-9691
forrestdevine7@gmail.com
Howland Partners, LLC c/o Arthur Howland, Manager
39 Brown Road, South Kent, CT 06785
R Levesque Associates, Inc.
40 School Street, Westfield, MA 01085
(413) 568-0985 (413) 568-0985
No
The applicant
proposes the construction of a multifamily residential development with associated site improvements, including
parking, utilities, landscaping, lighting, site grading, and stormwater management.
Yes
Forrest Devine
1,116
0
No
Salmon Brook (off-site)
No
No
NoPage 71
Granby Inland Wetlands and Watercourses Commission Application Checklist
N/A Appl. Documents Required
Applications and revised materials must be submitted to the Office of Community Development no later than 5 pm eight (8)
days prior to the IWWC meeting to be fully reviewed by the IWWC, otherwise applications may only be received.
An original of the completed application form and site plan and two (2) full size copies of the set of site plans and any reports.
Seven (7) 11X17 (or full size) sets copies of site plans and complete application, including one (1) complete digital copy of
submission.
Application Fee (see following page for calculation)
Pre and post development stormwater drainage calculations, with drainage area map, except for single-family homes, etc.
Report on soil types and characteristics from Professional Soil Scientist who delineated wetlands. Report shall include a
minimum of one field soil profile for each wetland soil type within project area. Profile shall be presented in data sheet format.
The applicant must certify whether any portion of the property is within 500 feet of an adjoining municipality, whether streets
from an adjoining municipality will be used for entering or exiting the site, whether sewer or water drainage will flow through or
impact an adjoining municipality or whether water run-off will impact streets or adjoining municipal or private property within an
adjoining municipality. If the project falls within any of the above mentioned definitions, then a letter must be sent by certified
mail to the adjoining municipalities Inland Wetlands Agency along with a copy of the application and site plan being submitted to
this Commission. Evidence of submission shall be submitted to the Granby IWWC.
For proposed wetland impacts, a wetland assessment report from a soil scientist or other qualified individual. Mitigation
activities shall also be described.
N/A Appl. Site Plan Requirements
Stamped by a Professional Engineer registered in the State of Connecticut.
Property boundaries, north arrow, name of project, date and type of drawing, subsequent dates of revision with description,
names and addresses of engineers and surveyors (when appropriate), location map, property owners(s) and adjacent property
owners.
Existing and proposed topography, structures, utilities, roadways and buildings. Plan/profile sheets shall be included for roads
and all off road pipelines.
Soil types as mapped by the National Resource Conservation Service.
Wetlands or watercourses located on adjacent properties when proposed activities may be located in the Upland Review Area.
Alternatives considered and rejected to be either shown on a site plan or explained in narrative form.
Soil and Erosion Control Measures including Narrative, per 2002 CT E&S Control Guidelines at a minimum.
Wetland boundaries delineated by a Professional Soil Scientist whose signatures is required on site plan.
Limits of Upland Review Areas.
Cuts and fill volumes indicating source and type of fill, destination of removed fill, except for single-family homes or similar.
Limits of woody vegetation clearing.
Well locations and setbacks from septic systems and drainage swales.
Septic system locations including reserve areas, existing and proposed grading, spot grades and setbacks from wetland areas.
Stormwater drainage systems.
All existing and proposed pipe sizes, lengths and inverts.
Test pit and soil profile locations.
Acreages of wetlands/watercourses on the site and the acreages presented separately of wetlands, watercourses or upland
review areas to be altered.
Boundaries of 100-year floodplain or floodways as determined by FEMA.
Erosion and sediment control details along with a sequence plan.
Test pit logs
Details of all proposed site improvements (i.e. drainage structures, pipes, footing drains, curtain drains, dewatering, cross section
of septic system or sewer connection, cross section of detention, retention, or sediment basins, etc.)
Construction sequence specifications.
N/A Appl. Public Hearing (If Required)
The Town of Granby Office of Community Development is responsible for publishing the legal notice.
THE GRANBY IWWC MAY REQUEST ADDITIONAL INFORMATION DURING THE PERMIT PROCESS AS NECESSARY.
Page 72
41
SECTION 19
FEES
19.5 Fee Schedule. Application fees shall be based on the following schedule.
ACTIVITY FEE/ AREA / # APPLIED
State of Connecticut Land Use Fee $60.00 $ 60.00 +
Permitted Uses As-of-Right & Non-Regulated Uses None None
CATEGORY 1 - RESIDENTIAL/SINGLE-FAMILY RESIDENCES (INCLUDING 2-LOT SUBDIVISIONS)
I. Base Fee
a. General Application $150.00 + II $ +
b. Accessory to Existing Primary Structure $80.00 + II $ +
c. Modification to Existing Approval $30.00 + II $ +
II. Activity Fee
a. $100.00 per Watercourse Crossing _________ (#) $ +
b. $0.02 per sq. ft. of Wetland Disturbance SF $ +
Within Upland Review Area…
c. $100.00 per Structure (greater than 200 sq. ft.) _________(#) $ +
d. $0.01 per sq. ft. of Impervious Surface _________SF $ +
e. $250.00 per Stormwater Management Basin _________ (#) $ +
f. $100.00 per Storm Drain Outfall _________ (#) $ +
g. $0.01 per sq. ft. of Steep Slope Disturbance _________SF $ +
(Slopes Greater than 2:1 – Define Area on Plan)
h. $0.005 per sq. ft. of Woody Vegetation Clear-Cut _________SF $ +
TOTAL FEE – CATEGORY 1 $
CATEGORY 2 - SUBDIVISIONS (GREATER THAN 2-LOTS)/CONDOMINIUMS, MULTI-FAMILY UNITS/COMMERCIAL
I. Base Fee
a. General Application Per Primary Structure (up to 5) $300.00/(+II) $ +
i. Fee Per Each Primary Structure Beyond 5 $20.00 (+II) $ +
b. Accessory to Existing Primary Structure $150.00 (+II) $ +
c. Modification to Existing Approval $60.00 (+II) $ +
II. Activity Fee*
a. $200.00 per Watercourse Crossing _________ (#) $ +
b. $0.04 per sq. ft. of Wetland Disturbance SF $ +
Within Upland Review Area…
c. $100.00 per Structure _________(#) $ +
d. $0.02 per sq. ft. of Impervious Surface _________SF $ +
e. $250.00 per Stormwater Management Basin _________ (#) $ +
f. $100.00 per Storm Drain Outfall _________ (#) $ +
g. $0.02 per sq. ft. of Steep Slope Disturbance _________SF $ +
(Slopes Greater than 2:1 – Defined Area on Plan)
h. $0.01 per sq. ft. of Woody Vegetation Clear-Cut _________SF $ +
TOTAL FEE – CATEGORY 2 $
0.00
300.00
N/A
N/A
1
6,760
135.20
0
0
0
0
435.20Page 73
42
ACTIVITY FEE/ AREA / # APPLIED
CATEGORY 3 – ALL OTHER APPLICATIONS
I. Base Fee
a. General Application $200.00 (+II) $ +
b. Modification to Existing Approval $60.00 (+II) $ +
II. Activity Fee*
a. $200.00 per Watercourse Crossing _________(#) $ +
b. $0.04 per sq. ft. of Wetland Disturbance SF $ +
Within Upland Review Area…
c. $100.00 per Structure _________(#) $ +
d. $0.02 per sq. ft. of Impervious Surface _________SF $ +
e. $250.00 per Stormwater Management Basin _________(#) $ +
f. $100.00 per Storm Drain Outfall _________(#) $ +
g. $0.02 per sq. ft. of Steep Slope Disturbance _________SF $ +
(Slopes Greater than 2:1 – Defined Area on Plan)
h. $0.01 per sq. ft. of Woody Vegetation Clear-Cut _________SF $ +
TOTAL FEE – CATEGORY 3 $
III. Significant Activity Fee $300.00 $ +
IV. Permit Extension Fee
a. Residential Uses $40.00 $ +
b. Commercial/Industrial/Other Uses $80.00 $ +
V. Map and Regulation Amendments $250.00 $ +
APPLICATION FEE SUBTOTAL $ +
VI. Post Activity Application Fee 20% of Fee Subtotal $ +
TOTAL APPLICATION FEE: $
Boards, Commissions, Agencies and Departments of the Town of Granby are exempt from all fee requirements.
VII. Complex Application Fee – Section 22a-42a of the Connecticut General Statutes states that an
applicant shall pay a fee equal to the Town’s expenditures in hiring outside consultants and
experts to analyze, review and report on issues requiring such experts. Such fee may include,
but not be limited to, the cost of retaining experts to analyze, review, and report on issues
requiring such experts. The Commission or the duly authorized agent shall estimate the
complex application fee which shall be paid pursuant to section 19.1 of these regulations
within 10 days of the applicant’s receipt or notice of such estimate. Any portion of the complex
application fee in excess of the actual cost shall be refunded to the applicant no later than 30
days after publication of the Commission’s decision.
0.00
495.20
N/A
495.20Page 74
1 rev. 12/2016 pdf 79 Elm Street • Hartford, CT 06106-5127 www.ct.gov/deep Affirmative Action/Equal Opportunity Employer STATEWIDE INLAND WETLANDS & WATERCOURSES ACTIVITY REPORTING FORM Pursuant to section 22a-39(m) of the General Statutes of Connecticut and section 22a-39-14 of the Regulations of Connecticut State Agencies, inland wetlands agencies must complete the Statewide Inland Wetlands & Watercourses Activity Reporting Form for each action taken by such agency. This form may be made part of a municipality's inland wetlands application package. If the municipality chooses to do this, it is recommended that a copy of the Town and Quadrangle Index of Connecticut and a copy of the municipality's subregional drainage basin map be included in the package. Please remember, the inland wetlands agency is responsible for ensuring that the information provided is accurate and that it reflects the final action of the agency. Incomplete or incomprehensible forms will be mailed back to the agency. Instructions for completing the form are located on the following pages. The inland wetlands agency shall mail completed forms for actions taken during a calendar month no later than the 15th day of the following month to the Department of Energy and Environmental Protection (DE EP). Do not mail this cover page or the instruction pages. Please mail only the completed reporting form to: DEEP Land & Water Resources Division Inland Wetlands Management Program 79 Elm Street, 3rd Floor Hartford, CT 06106 Questions may be directed to the DEEP's Inland Wetlands Management Program at (860) 424-3019.
Page 75
2 rev. 12/2016 pdf INSTRUCTIONS FOR COMPLETING THE STATEWIDE INLAND WETLANDS & WATERCOURSES ACTIVITY REPORTING FORM Use a separate form to report EACH action taken by the Agency. Complete the form as described below. Do NOT submit a reporting form for withdrawn actions. PART I: Must Be Completed By The Inland Wetlands Agency 1. Choose the year and month the Inland Wetlands Agency took the action being reported. If multiple actions were taken regarding the same project or activity then multiple forms need to be completed. 2.Choose ONE code letter to describe the final action or decision taken by the Inland Wetlands Agency. Do NOT submit a reporting form for withdrawn actions. Do NOT enter multiple code letters (for example: if an enforcement notice was given and subsequent permit issued - two forms for the two separate actions are to be completed). A = A Permit Granted by the Inland W etlands Agency (not including map amendments, see code D below) B = Any Permit Denied by the Inland Wetlands Agency C = A Permit Renewed or Amended by the Inland Wetlands Agency D = A Map Amendment to the Official Town Wetlands Map - or - An Approved/Permitted Wetland or Watercourse Boundary Amendment to a Project Site Map E = An Enforcement Action: Permit Revocation, Citation, Notice of Violation, Order, Court Injunction, or Court Fines F = A Jurisdictional Ruling by the Inland Wetlands Agency (i.e.: activities "permitted as of right" or activities consider ed non-regulated) G = An Agent Approval pursuant to CGS 22a-42a(c)(2) H = An Appeal of Agent Approval Pursuant to 22a-42a(c)(2) 3.Check "yes" if a public hearing was held in regards to the action taken; otherwise check "no". 4. Enter the name of the Inland Wetlands Agency official verifying that the information provided on this form is accurate and that it reflects the FINAL action of the agency. PART II: To Be Completed By The Inland Wetlands Agency Or The Applicant - If Part II is completed by the applicant, the applicant MUST return the form to the Inland Wetlands Agency. The Inland Wetlands Agency MUST ensure that the information provided is accurate and that it reflects the FINAL action of the Agency. 5. Enter the name of the municipality for w hich the Inland Wetlands Agency has jurisdiction and in which the action/project/activity is occurring. Check "yes" if the action/project/activity crosses municipal boundaries and enter the name(s) of the other municipality(ies) where indicated. Check "no" if it does not cross municipal boundaries. 6. Enter the USGS Quad Map name or number (1 through 115) as found on the Connecticut Town and Quadrangle Index Map (the directory to all USGS Quad Maps) that contains the location of the action/project/activity. Click on the following website for USGS Quad Map information: http://ct.gov/deep/lib/deep/gis/resources/Index_NamedQuadTown.pdf ALSO enter the four-digit identific ation number of the corresponding Subregional Drainage Basin in which the action/project/activity is located. If the action/project/activity is located in more than one subregional drainage basin, enter the number of the basin in which the majority of the action/project/activity is located. Town subregional drainage basin maps can be found at UConn – CLEAR’s website: http://clear.uconn.edu/data/map_set/index.htm 7. Enter the name of the individual apply ing for, petitioning, or receiving the action. 8.Enter the name and address or location of the action/project/activity. Check if the action/project/activity is TEMPORARY or PERMANENT in nature. Also provide a brief DESCRIPTION of the action/project/activity. It is always best to provide as much information as possible (i.e., don't just state "forestry", provide details such as "20 acre forestry harvest, permit required for stream crossing".)
Page 76
3 rev. 12/2016 pdf 9.Carefully review the list below and enter ONLY ONE code letter which best characterizes the action/project/activity. All state agency projects must code "N". A = Residenti al Improvement by Homeowner I = Storm Water / Flood Control B = New Residential Development for Single Family Units J = Erosion / Sedimentation Control C = New Residential Development for Multi-Family / Condos K = Recreation / Boating / Navigation D = Commercial / Industrial Uses L = Routine Maintenance E = Municipal Project M = Map Amendment F = Utility Company Project N = State Agency Project G = Agriculture, Forestry or Conservation P = Other (this code includes the approval of H = Wetland Restoration, Enhancement, Creation concept plans with no-on-the-ground work) 10. Enter between one and four code numbers to best characterize the project or activity being reported. Enter "NA" if this form is being completed for the action of map amendment. You MUST provide code 12 if the activity is located in an established upland review area. You MUST provide code 14 if the activity is located beyond the established upland review area or no established upland review area exists. 1 = Filling 8 = Underground Utilities Only (no other activities) 2 = Excav ation 9 = Roadway / Driveway Construction 3 = Land Clearing / Grubbing (no other activity) 10 = Drainage Improvements 4 = Stream Channelization 11 = Pond, Lake Dredging / Dam Construction 5 = Stream Stabilization (includes lakeshore stabilization) 12 = Activity in an Established Upland Review 6 = Stream Clearance (removal of debris only) Area 7 = Culverting (not for roadways) 14 = Activity in Upland Examples: Jur isdictional ruling allowing construction of a parking lot in an upland where the municipality does not have an established upland review area must use code 14, other possible codes are 2 and 10. Permitted construction of a free standing garage (residential improvement by homeowner) partially in an established upland review area with the remainder in the upland must use code 12 and 14, other possible codes are 1 and 2. 11. Leave blank f or TEMPORARY alterations but please indicate action/project/activity is temporary under question #8 on the form. For PERMANENT alterations, enter in acres the area of wetland soils or watercourses altered. Include areas that are permanently altered, or are proposed to be, for all agency permits, denials, amendments, renewals, jurisdictional rulings, and enforcement actions. For those activities that involve filling or dredging of lakes, ponds or similar open water bodies enter the acres filled or dredged under "open water body". For those activities that involve directly altering a linear reach of a brook, river, lakeshore or similar linear watercourse, enter the total linear feet altered under "stream". Remember that these figures represent only the acreage altered not the total acreage of wetlands or watercourses on the site. You MUST provide all information in ACRES (or linear feet as indicated) including those areas less than one acre. To convert from square feet to acres, divide square feet by the number 43,560. If this report is being completed for an agency jurisdictional ruling and detailed information is not available, provide an estimate. Enter zero if there is no alteration. 12. Enter in ac res the area of upland altered as a result of an ACTIVITY REGULATED BY the inland wetlands agency, or as a result of an AGENT APPROVAL pursuant to CGS section 22a-42a(c)(2). Leave blank for TEMPORARY alterations but please indicate action/project/activity is temporary under question #8 on the form. Include areas that are permanently altered, or proposed to be permanently altered, for all agent approvals, agency permits, denials, amendments, renewals, jurisdictional rulings, and enforcement actions. You MUST provide all information in ACRES including those areas less than one acre. See directions above (#11) for conversion factor. If this report is being completed for an agent approval or an agency jurisdictional ruling and detailed information is not available, provide an estimate. Enter zero if there is no alteration. 13. Enter the ac res that are, or are proposed to be, restored, enhanced or created for all agency permits, denials, amendments, renewals, jurisdictional rulings and enforcement actions. NOTE restored or enhanced applies to previously existing wetlands or watercourses. Created applies to a non-wetland or non-watercourse area which is converted into wetlands or watercourses (question #10 must provide 12 and/or 14 as an answer, and question #12 must also be answered). You MUST provide all information in ACRES including those areas less than one acre. See directions above (#11) for conversion factor. Enter zero if there is no restoration, enhancement or creation. PART III: To Be Completed By The DEEP - Please leave this area blank. Incomplete or incomprehensible forms will be mailed back to the inland wetlands agency.
Page 77
rev. 12/2016 pdf 79 Elm Street • Hartford, CT 06106-5127 www.ct.gov/deep Affirmative Action/Equal Opportunity Employer Statewide Inland Wetlands & Watercourses Activity Reporting Form Please complete and mail this form in accordance with the instructions on pages 2 and 3 to: DEEP Land & Water Resources Division, Inland Wetlands Management Program, 79 Elm Street, 3rd Floor, Hartford, CT 06106 Incomplete or incomprehensible forms will be mailed back to the inland wetlands agency. PART I: Must Be Completed By The Inland Wetlands Agency 1.DATE ACTION WAS TAKEN: year: ______________ month: ______________ 2.ACTION TAKEN (see instructions, only use one code): ______________ 3.WAS A PUBLIC HEARING HELD (check one)? yes no 4. NAME OF AGENCY OFFICIAL VERIFYING AND COMPLETING THIS FORM: (print name) (signature) ________________________________________________ PART II: To Be Completed By The Inland Wetlands Agency Or The Applicant 5. TOWN IN WHICH THE ACTION IS OCCURRING (print name): ______________________________________________________ does this project cross municipal boundaries (check one)? yes no if yes, list the other town(s) in which the action is occurring (print name(s)): ____________________, ______________________ 6. LOCATION (see instructions for information): USGS quad name: _____________________________ or number: __________ subregional drainage basin number: _______________________ 7. NAME OF APPLICANT, VIOLATOR OR PETITIONER (print name): __________________________________________________ 8. 9.ACTIVITY PURPOSE CODE (see instructions, only use one code): ___________ 10.ACTIVITY TYPE CODE(S) (see instructions for codes): __________, __________, __________, __________ 11.WETLAND / WATERCOURSE AREA ALTERED (must provide acres or linear feet): 12.UPLAND AREA ALTERED (must provide acres): ____________ acres 13.AREA OF WETLANDS / WATERCOURSES RESTORED, ENHANCED OR CREATED (must provide acres): ____________ acres DATE RECEIVED: PART III: To Be Completed By The DEEP DATE RETURNED TO DEEP: FORM COMPLETED: YES NO FORM CORRECTED / COMPLETED: YES NO GIS CODE #: ____ ____ ____ ____ ____ ____ ____ ____ ____ For DEEP Use Only NAME & ADDRESS / LOCATION OF PROJECT SITE (print information): _______________________________________________ briefly describe the action/project/activity (check and print information): temporary permanent description: ____________ _______________________________________________________________________________________________________________________ wetlands: ____________ acres open water body: ____________ acres stream: ____________ linear feet Granby 37 Hartford Avenue, Granby, CT Proposed Residential Development C 12 0 0 0 0 Forrest Devine 0.33
Page 78
3. PROJECT NARRATIVE
Page 79
Page | 1 PROJECT NARRATIVE For 37 HARTFORD AVENUE GRANBY, CONNECTICUT 06035 (PARCEL ID: 4254) INTRODUCTION On behalf of the applicant, Forrest Devine, R Levesque Associates, Inc. (RLA) is providing this project narrative as a supplement to the Application for Inland Wetlands & Watercourses Activity. The applicant proposes the construction of a multifamily residential development with associated site improvements within the 100’ Upland Review Area to a Wetland and 200’ Upland Review Area to a Watercourse (tributary to Salmon Brook). PROPERTY DESCRIPTION The subject property is located southwest of Hartford Avenue and consists of approximately 111,198 ± SF as shown on the associated site plan as prepared by R Levesque Associates, Inc. The property is owned by Howland Partners, LLC and is recorded in the Granby Town Clerks Records under Volume 349, Page 667. EXISTING CONDITIONS & TOPOGRAPHY The subject property is partially developed with an existing building foundation, impervious parking area and associated paved driveway, and yard area . The topography of the site generally varies, sloping from the north to the south towards wetlands within the rear of the property. A Topographic Map is included within this application packet under Section 4, as Figure 1. ENVIRONMENTAL FACTORS The subject property is not located within a Special Flood Zone Area according to Flood Insurance Rate Map (FIRM) Number 09003C0183F effective dated September 26, 2008. A review of CT ECO mapping showed the subject property is not located within a Natural Diversity Area.
Page 80
Page | 2 PROPOSED PROJECT DESCRIPTION The applicant proposes the construction of a residential development with associated site improvements. Associated site improvements include, but are not limited to, parking, utilities, stormwater management, site grading, landscaping, and lighting. The proposed project work will proceed in the following general construction sequence: 1. Install perimeter erosion and sedimentation controls in accordance with the approved plans; 2. Clear and grub limits of disturbance; 3. Establish construction entrance; 4. Perform rough grading to establish subgrades for building and drainage system; 5. Install and construct underground utilities, including septic system; 6. Construct stormwater management system; 7. Construct a three-story multifamily residential building; 8. Install curbing, sidewalks, and pavement for entry way and parking area; 9. Complete final grading, place topsoil, and site stabilization; and 10. Remove temporary erosion and sedimentation controls after site stabilization is achieved and Town of Granby sign-off is received. SOILS & EROSION CONTROL MEASURES According to the NRCS Web Soil Survey, the soil types mapped within the subject property consist of: Agawam fine sandy loam, 0 to 3 percent slopes (29A), Hinckley loamy sand, 15 to 45 percent slopes (38E), and Saco silt loam, 0 to 2 percent slopes (108). Please refer to the attached NRCS Web Soil Survey Map, which is included within this application packet, under Section 4, as Figure 3. A siltation fence is proposed downslope of the proposed residential addition to intercept and contain sediment generated during construction, providing protection for the brook and its surrounding resource areas. The fence will follow the natural contours where feasible and will be keyed into the ground to prevent bypassing. All materials and installation methods will meet standard erosion control practices to ensure effective filtration during soil disturbance activities. The fence will be fully in place and available for inspection by the IWWA before any construction work begins. Said fencing will remain in place until removal is directed by the IWWA.
Page 81
Page | 3 WETLAND RESOURCE AREAS Wetland resource areas were delineated by Ryan Nelson, Registered Soil Scientist (SSSSNE) in March of 2026. Please refer to Section 4 of this application packet for a detailed wetland scientist report. Please note that resource area flags shown off-site are shown for reference purposes only and the determination of such is not the subject of this filing. Tributary to “Salmon Brook” The northern Bank of a stream tributary to Salmon Brook was delineated and is shown on the associated filing plans with flagging labeled “BNK -100” through “BNK -145”. No disturbance to Bank is proposed as part of this filing. 200’ Upland Review Area from Watercourse The 200’ Upland Review Area is shown offset 200’ from the Bank flags . Proposed work within the 200’ Upland Review Area consists of portions of the proposed parking area, the pavilion, dumpster enclosure, and associated site grading activities. Certain components of the proposed drainage system, such as catch basins and associated pipe network, are also located within the Upland Review Area. However, the proposed building, subsurface stormwater system, and associated utility connections are located outside of the Upland Review Area. 200’ Upland Review Area (On-Site Total) 17,352 SF 200’ Upland Review Area (Proposed Disturbance) 10,145 SF Wetland An inland wetland was delineated and is shown on the associated filing plans with flagging labeled “A-1” through “A-22”. No disturbance to the wetland is proposed as part of this filing.
Page 82
Page | 4 100’ Upland Review Area from Wetland The 100’ Upland Review Area is shown offset 100’ from the boundary of the delineated wetland. Proposed work within the 100’ Upland Review Area is limited in scope and consists only of minor encroachment of portions of the proposed parking area and associated site grading. No structures are proposed within this buffer, and impacts are generally confined to grading transitions and surface improvements tied to the parking layout. All remaining site elements are located outside of the 100’ Upland Review Area. 100’ Upland Review Area (On-Site Total) 54,291 SF 100’ Upland Review Area (Proposed Disturbance) 4,642 SF ALTERNATIVE ANALYSIS Alternative #1 – Keeping all disturbance outside the Upland Review Area An alternative that maintains all disturbance outside the Upland Review Area was evaluated; however, this approach is not practicable given the existing site constraints and development history. The previously disturbed limits extend into the upland review area, and avoiding this area entirely would require shifting or reducing th e project beyond the already degraded footprint. Such reconfiguration would result in inefficient site layout, potential impacts to previously undisturbed upland areas, and challen ges in accommodating required access, utilities, and stormwater management infrastructure. The proposed design instead concentrates redevelopment within the same general existing disturbed footprint, minimizing expansion and avoiding encroachment into more sensitive, undisturbed areas. As a result, the project represents a balanced approach that limits environmental impact while allowing reasonable use of the property. Alternative #2 – No Build The no-build alternative would avoid any additional disturbance to the site; however, it would leave the property in its current degraded and unmanaged condition. The site has remained vacant following prior clearing, grading, and partial construction, resulting in an area that lacks stabilization, formal stormwater management, and ecological function. Under a no -build scenario, these conditions would persist, with no improvements to drainage, water quality, or site restoration. In contrast, the proposed multifamily development includes comprehensive site improvements such as stormwater management
Page 83
Page | 5 systems, controlled grading, and landscaping, which will enhance site stability and environmental performance. Accordingly, the proposed project provides a net benefit compared to the no -build alternative by improving existing degraded conditions while limiting disturbance to previously impacted areas. Based on the two alternatives , both are either impractical or fail to improve existing site conditions. The proposed addition represents the most feasible and environmentally responsible option, limiting disturbance while allowing for the introduction of erosion controls and site restoration. CRITERIA FOR DECISION The following text is taken directly from the Town of Granby IWWA Regulations Section 10.2 and is presented below in italic text, followed by an RLA Response presented below in boldface text. A. The environmental impact of the proposed regulated activity on wetlands or watercourses; RLA Response: The proposed project has been designed to avoid direct impacts to wetlands and watercourses, with all site improvements located outside of delineated resource areas. Work within the upland review area is limited and does not include permanent structures . Erosion and sedimentation controls will be implemented during construction to prevent off-site transport of sediments. B. The applicant’s purpose for, and any feasible and prudent alternatives to, the proposed regulated activity which alternatives would cause less or no environmental impact to wetlands or watercourses; RLA Response: The purpose of the project is to develop a multifamily residential building with associated site improvements on a previously disturbed and vacant property. Alternatives that would entirely avoid the upland review area or reduce the project footprint were considered but found to be impracticable due to the extent of existing disturbance and site constraints. C. The relationship between the short -term and long -term impacts of the proposed regulated activity on wetlands or watercourses and the maintenance and enhancement of long-term productivity of such wetlands or watercourses;
Page 84
Page | 6 RLA Response: Short-term impacts are limited to typical construction -related disturbances such as earthwork and utility installation within previously disturbed areas, which will be managed through erosion and sedimentation controls. Long - term conditions are expected to improve relative to existing site conditions, which currently lack formal stormwater management and stabilization. The project includes permanent stormwater treatment measures, controlled grading, and vegetative stabilization, which will red uce pollutant loading and improve runoff characteristics. D. Irreversible and irretrievable loss of wetland or watercourse resources which would be caused by the proposed regulated activity, including the extent to which such activity would foreclose a future ability to protect, enhance or restore such resources, and any mitigation measures which may be considered as a condition of issuing a permit for such activity including, but not limited to, measures to (1) prevent or minimize pollution or other environmental damage, (2) maintain or enhance existing environmenta l quality, or (3) in the following order of priority: restore, enhance and create productive wetland or watercourse resources; RLA Response: No irreversible or irretrievable loss of wetlands or watercourses is proposed, as no direct alteration or filling of these resources will occur. The project has been designed to avoid encroachment into delineated wetland boundaries and to confine activity. Mitigation measures include the installation and maintenance of erosion and sedimentation controls during construction, implementation of stormwater management systems to treat and attenuate runoff, and restoration of disturbed areas with topsoil and vegetation. E. The character and degree of injury to, or interference with safety, health or the reasonable use of property which is caused or threatened by the proposed regulated activity; RLA Response: The proposed regulated activity is not anticipated to result in injury to public safety, health, or the reasonable use of surrounding properties. The development includes an engineered stormwater management system designed to control runoff and prevent flooding or erosion impacts to adjacent properties. Improvements to site grading and drainage will enhance existing conditions, which are currently unmanaged due to the site’s vacant and disturbed state. F. Impacts of the proposed regulated activity on wetlands or watercourses outside the area for which the activity is proposed and future activities associated with or
Page 85
Page | 7 reasonably related to, the proposed regulated activity which are made inevitable by the proposed regulated activity and which may have an impact on wetlands and watercourses. RLA Response: The proposed activity is not expected to result in impacts to wetlands or watercourses beyond the project area. Construction controls and permanent stormwater management measures are designed to prevent sedimentation, erosion, and pollutant transport to of f-site resources. The project represents a standalone redevelopment of a previously disturbed property and does not induce or necessitate additional future activities that would impact wetlands or watercourses. Any future site modifications would be subject to separate review and permitting, as applicable. CONCLUSION The proposed multifamily residential development has been carefully designed to avoid direct impacts to wetlands and watercourses while minimizing work within the upland review area. The project is mostly confined to a previously degraded portion of the site. Implementation of erosion and sedimentation controls, along with permanent stormwater management measures, will ensure protection of adjacent resource areas during both construction and long-term operation. Compared to existing unmanaged conditions, th e project is expected to provide improved site stabilization and water quality treatment. T he proposed activity is consistent with applicable regulatory criteria and will not result in significant adverse environmental impacts. Based on the foregoing, the applicant respectfully requests approval from the IWWA. [ END OF PROJECT NARRATIVE ]
Page 86
4. WETLAND SCIENTIST / SOIL REPORT
Page 87
R LEVESQUE ASSOCIATES, INC. 40 School Street, P.O. BOX 640, Westfield, MA 01085 p 413.568.0985 · f 413.568.0986 · www.rlaland.com 1 May 27, 2026 John L. Laudati, Chairman Town of Granby Inland Wetlands & Watercourses Commission 15 North Granby Road Granby, Connecticut 06035 RE: Wetland Scientist Report 37 Hartford Avenue, Granby, Connecticut 06035 (Parcel ID: 4254) RLA Project File No. 251219 Dear Chairman Laudati, On March 26, 2026, I conducted an inspection of the above referenced property to delineate inland wetland soils and/or watercourses within a jurisdictional vicinity to the project site. Using a hand soil auger, I observed soil profiles to a depth of approximately 2 to 3 feet. The property contains an existing concrete building foundation with various drainage and utility site improvements resulting from a previous unfinished project. The applicant proposes the construction of a multifamily residential development with associated site improvements, portions of which are proposed within the 100’ Upland Review Area to a Wetland and 200’ Upland Review Area to a Watercourse (tributary to West Branch Salmon Brook). Findings Wetland Resource Areas Based on guidelines established by the National Cooperative Soil Survey and as defined by Connecticut Public Act 72-155, as amended by CT P.A. 73-571, CT P.A. 87-338, CT P.A. 87-533, I delineated a forested inland wetland located proximate to, and mostly south of, the southerly property line. Please note that offsite wetland resource areas have been delineated to accurately project upland review area jurisdiction onto the subject property, and the determination of off-site wetland resource areas owned by others is not the subject of this filing. The northerly boundary of the forested wetland has been delineated with pink flagging labeled “A1” through “A22”. The wetland border follows the edge of an existing gravel/dirt path that appears to have been constructed many decades ago. All of the wetland areas are classified as a forested wetland general classification. This wetland area has functions that include: groundwater recharge and discharge, sediment stabilization, nutrient removal and transformation, product export, and wildlife diversity and habitat. The vegetative over-story includes maples, ash, black cherry, and poplar. Shrub species include winterberry, spice bush, and dogwood. The herbaceous layer
Page 88
R LEVESQUE ASSOCIATES, INC. 40 School Street, P.O. BOX 640, Westfield, MA 01085 p 413.568.0985 · f 413.568.0986 · www.rlaland.com 2 includes sensitive fern, poison ivy, fox grape, jack in the pulpit and skunk cabbage. The wetland area has a diverse native vegetation population at the herbaceous, shrub and tree layers. No evidence of invasive species was observed. It is anticipated that wildlife utilizes this wetland corridor as a source of food, water, and shelter. An unnamed stream was also observed within said forested wetland. Said stream appears to be a tributary to West Branch Salmon Brook. The northerly top of bank of the stream has been delineated with blue flags labeled “BNK-100” through “BNK-145”. The stream is located off-site but has been shown to accurately project a 200’ Watercourse Upland Review Area onto the subject property. Soils The upland area is comprised of a Hinckley loamy sand (38E), 15 to 45 percent slopes, that transitions to a Saco silt loam (108), frequently ponded, 0 to 2 percent slopes near the wetland. Saco silt loam is classified as a very poorly drained soil. These soils are formed in alluvial stratified sand and silt loams. These soils are on low flood plains along stream and rivers and are frequently flooded. Upland Area The upland review area consists of gravel and mixed vegetated surfaces with stormwater drainage structures installed from a prior project. The proposed project is not proposed to alter the wetland or stream, but is located within the upland review area. It is anticipated that the proposed project will occur generally within the limits of disturbance from previous projects, and the wetland resource areas will continue to function undisturbed. Recommendations With adequate erosion and sedimentation controls implemented during construction, and implementation of a stormwater management design, it is anticipated that the proposed development will not have a significant adverse impact on the adjacent inland wetlands and/or watercourses. If you have any questions regarding this matter, please contact me at ryann@rlaland.com Sincerely, R LEVESQUE ASSOCIATES, INC. Ryan Nelson Wetland Scientist Registered Soil Scientist (SSSSNE)
Page 89
Page 90
Page 91
Page 92
Page 93
Page 94
Page 95
5-27-2026 37 Hartford Ave, Granby, CT Wetland Delineation Photos Figure 1 - "T1-WET" transect vegetation Figure 2 - "T1-WET" transect hydric soil
Page 96
Figure 3 - "T1-UP" transect non-hydric soil Figure 4 - "T1-UP" transect vegetation
Page 97
5. FIGURES 5.1 FIGURE 1 – USGS LOCUS MAP 5.2 FIGURE 2 – FEMA FLOODPLAIN MAP 5.3 FIGURE 3 – NRCS SOIL MAP 5.4 FIGURE 4 – NATURAL DIVERSITY DATA BASE
Page 98
Granby CT ECO Map Sources: Esri, TomTom, Garmin, FAO, NOAA, USGS, © OpenStreetMap contributors, and the GIS User Community, Sources: Esri, Vantor, Airbus DS, USGS, NGA, NASA, CGIAR, N Robinson, NCEAS, NLS, OS, NMA, Geodatastyrelsen, Rijkswaterstaat, GSA, Geoland, FEMA, CT Municipalities World_Hillshade 4/21/2026, 12:57:48 PM 0 0.01 0.030.01 mi 0 0.03 0.050.01 km 1:943 Map created with the CT ECO Advanced Viewer. Visit CT ECO at This map is intended for general planning, management, education, and research purposes only. Data shown on this map may not be complete or current. The data shown may have been compiled at different times and
Page 99
National Flood Hazard Layer FIRMette 0 500 1,000 1,500 2,000250 Feet Ü SEE FIS REPORT FOR DETAILED LEGEND AND INDEX MAP FOR FIRM PANEL LAYOUT SPECIAL FLOOD HAZARD AREAS Without Base Flood Elevation (BFE) Zone A, V, A99 With BFE or Depth Zone AE, AO, AH, VE, AR Regulatory Floodway 0.2% Annual Chance Flood Hazard, Areas of 1% annual chance flood with average depth less than one foot or with drainage areas of less than one square mile Zone X Future Conditions 1% Annual Chance Flood Hazard Zone X Area with Reduced Flood Risk due to Levee. See Notes. Zone X Area with Flood Risk due to Levee Zone D NO SCREEN Area of Minimal Flood Hazard Zone X Area of Undetermined Flood Hazard Zone D Channel, Culvert, or Storm Sewer Levee, Dike, or Floodwall Cross Sections with 1% Annual Chance 17.5 Water Surface Elevation Coastal Transect Coastal Transect Baseline Profile Baseline Hydrographic Feature Base Flood Elevation Line (BFE) Effective LOMRs Limit of Study Jurisdiction Boundary Digital Data Available No Digital Data Available Unmapped This map complies with FEMA's standards for the use of digital flood maps if it is not void as described below. The basemap shown complies with FEMA's basemap accuracy standards The flood hazard information is derived directly from the authoritative NFHL web services provided by FEMA. This map was exported on 4/21/2026 at 5:04 PM and does not reflect changes or amendments subsequent to this date and time. The NFHL and effective information may change or become superseded by new data over time. This map image is void if the one or more of the following map elements do not appear: basemap imagery, flood zone labels, legend, scale bar, map creation date, community identifiers, FIRM panel number, and FIRM effective date. Map images for unmapped and unmodernized areas cannot be used for regulatory purposes. Legend OTHER AREAS OF FLOOD HAZARD OTHER AREAS GENERAL STRUCTURES OTHER FEATURES MAP PANELS 8 B 20.2 The pin displayed on the map is an approximate point selected by the user and does not represent an authoritative property location. 1:6,000 72°47'22"W 41°57'10"N 72°46'45"W 41°56'43"N Basemap Imagery Source: USGS National Map 2023
Page 100
Soil Map—State of Connecticut, Western Part Natural Resources Conservation Service Web Soil Survey National Cooperative Soil Survey 4/21/2026 Page 1 of 3 4646290 4646320 4646350 4646380 4646410 4646440 4646470 4646500 4646530 4646560 4646590 4646290 4646320 4646350 4646380 4646410 4646440 4646470 4646500 4646530 4646560 4646590 683530 683560 683590 683620 683650 683680 683710 683740 683530 683560 683590 683620 683650 683680 683710 683740 41° 56' 59'' N 72° 47' 9'' W 41° 56' 59'' N 72° 46' 59'' W 41° 56' 49'' N 72° 47' 9'' W 41° 56' 49'' N 72° 46' 59'' WN Map projection: Web Mercator Corner coordinates: WGS84 Edge tics: UTM Zone 18N WGS84 0 50 100 200 300 Feet 0 20 40 80 120 Meters Map Scale: 1:1,510 if printed on A portrait (8.5" x 11") sheet. Soil Map may not be valid at this scale.
Page 101
MAP LEGEND MAP INFORMATION Area of Interest (AOI) Area of Interest (AOI) Soils Soil Map Unit Polygons Soil Map Unit Lines Soil Map Unit Points Special Point Features Blowout Borrow Pit Clay Spot Closed Depression Gravel Pit Gravelly Spot Landfill Lava Flow Marsh or swamp Mine or Quarry Miscellaneous Water Perennial Water Rock Outcrop Saline Spot Sandy Spot Severely Eroded Spot Sinkhole Slide or Slip Sodic Spot Spoil Area Stony Spot Very Stony Spot Wet Spot Other Special Line Features Water Features Streams and Canals Transportation Rails Interstate Highways US Routes Major Roads Local Roads Background Aerial Photography The soil surveys that comprise your AOI were mapped at 1:12,000. Warning: Soil Map may not be valid at this scale. Enlargement of maps beyond the scale of mapping can cause misunderstanding of the detail of mapping and accuracy of soil line placement. The maps do not show the small areas of contrasting soils that could have been shown at a more detailed scale. Please rely on the bar scale on each map sheet for map measurements. Source of Map: Natural Resources Conservation Service Web Soil Survey URL: Coordinate System: Web Mercator (EPSG:3857) Maps from the Web Soil Survey are based on the Web Mercator projection, which preserves direction and shape but distorts distance and area. A projection that preserves area, such as the Albers equal-area conic projection, should be used if more accurate calculations of distance or area are required. This product is generated from the USDA-NRCS certified data as of the version date(s) listed below. Soil Survey Area: State of Connecticut, Western Part Survey Area Data: Version 6, Sep 16, 2025 Soil map units are labeled (as space allows) for map scales 1:50,000 or larger. Date(s) aerial images were photographed: Jun 14, 2022—Jul 1, 2024 The orthophoto or other base map on which the soil lines were compiled and digitized probably differs from the background imagery displayed on these maps. As a result, some minor shifting of map unit boundaries may be evident. Soil Map—State of Connecticut, Western Part Natural Resources Conservation Service Web Soil Survey National Cooperative Soil Survey 4/21/2026 Page 2 of 3
Page 102
Map Unit Legend Map Unit Symbol Map Unit Name Acres in AOI Percent of AOI 29A Agawam fine sandy loam, 0 to 3 percent slopes 1.0 21.9% 38E Hinckley loamy sand, 15 to 45 percent slopes 3.0 63.2% 108 Saco silt loam, frequently ponded, 0 to 2 percent slopes, frequently flooded 0.7 14.9% Totals for Area of Interest 4.8 100.0% Soil Map—State of Connecticut, Western Part Natural Resources Conservation Service Web Soil Survey National Cooperative Soil Survey 4/21/2026 Page 3 of 3
Page 103
FF FF FF Granby CT ECO Map Sources: Esri, TomTom, Garmin, FAO, NOAA, USGS, © OpenStreetMap contributors, and the GIS User Community, Sources: Esri, Vantor, Airbus DS, USGS, NGA, NASA, CGIAR, N Robinson, NCEAS, NLS, OS, NMA, Geodatastyrelsen, Rijkswaterstaat, GSA, Geoland, FEMA, CT Municipalities Critical Habitats Beachshore Intertidal Marsh Acidic Atlantic White Cedar Swamp Acidic Red/Black Spruce Basin Swamp Circumneutral Northern White Cedar Swamp Floodplain Forest Beachshore Riverine Circumneutral Spring Fen Alluvial Marsh Freshwater Aquatic Medium Fen Poor Fen Rich Fen Sea Level Fen Coastal Woodland/Shrubland Dry Acidic Forest Dry Circumneutral Forest Dry Subacidic Forest Old Growth Forest Subacidic Cold Talus Forest/Woodland Acidic Rocky Summit Outcrop Alluvial Grassland/Outcrop Circumneutral Rocky Summit Outcrop Coastal Bluffs and Headlands Coastal Grassland Sand Barren Subacidic Rocky Summit Outcrop Natural Diversity Area World_Hillshade 4/21/2026, 1:00:49 PM 0 0.04 0.090.02 mi 0 0.07 0.140.04 km 1:2,631 Map created with the CT ECO Advanced Viewer. Visit CT ECO at This map is intended for general planning, management, education, and research purposes only. Data shown on this map may not be complete or current. The data shown may have been compiled at different times and
Page 104
6. ABUTTER NOTIFICATION 6.1 ABUTTER LIST – 100’ 6.2 ABUTTER NOTIFICATION LETTER (TO BE PROVIDED UPON CONFIRMATION IF PUBLIC HEARING IS NECESSARY)
Page 105
Abutting Property Owners - 100' 37 Hartford Avenue, Granby, CT 06035 (Parcel ID: 4254) Source: Town of Granby GIS Generated On: 05/27/2026 NAME ADDRESS TOWN STATE ZIP CODE ERIK & JENNIFER CHRISTENSEN 36 HARTFORD AVENUE GRANBY CT 06035 JON FYFE 40 HARTFORD AVENUE GRAMNY CT 06035 EST. OF DEBORAH ALVESTAD 10 TOWER LANE, SUITE 325 AVON CT 06001 *INFORMATION SUPPRESSED BY TAXPAYER* 44 HARTFORD AVENUE GRANBY CT 06035 KEVIN & LAURA LAFLAMME 49 HARTFORD AVENUE GRANBY CT 06035 JAMES & AMANDA RAY 933 OX YOKE ROAD ORANGE CT 06477 NOAH & MEGHAN DAVINI 43 HARTFORD AVENUE GRAMBY CT 06035 MDU REALTY, LLC PO BOX 390 GRANBY CT 06035 FRANCIS REAL ESTATE HOLDINGS, LLC 488 NEWTON STREET SOUTH HADLEY MA 01075 RACHELLE CINQUE, TRUSTEE & MALCOM MCGREGOR 23 BEEHOLM ROAD REDDING CT 06896 KEVIN COUSIN 65 WINDMILL DRIVE GRANBY CT 06035 PETER VOSKOWSKY 53 WINDMILL DRIVE GRANBY CT 06035
Page 106
APPENDIX A: SITE PLAN SET SITE PLAN SET ENTITLED “PROPOSED RESIDENTIAL DEVELOPMENT” PREPARED FOR FORREST DEVINE PREPARED BY R LEVESQUE ASSOCIATES, INC. DATED MAY 28, 2026
Page 107
APPENDIX B: STORMWATER REPORT STORMWATER DRAINAGE REPORT PREPARED FOR FORREST DEVINE PREPARED BY R LEVESQUE ASSOCIATES, INC. DATED MAY 28, 2026
Page 108
E HARTFORD AVE PROPOSED RESIDENTIAL BUILDING EXISTING DRIVEWAY SEPTIC DESIGN PLAN REV. RLA PROJ. NUMBER: DRAWING# OF MASSACHUSETTS STATE LAW THIS DOCUMENT IS A VIOLATION UNAUTHORIZED ALTERATION OF DATE: ISSUANCE DATE: REVISIONS: PREPARED FOR: ph: 413.568.0985 fax: 413.568.0986 rlaland.com Westfield, MA 01085 R L A 40 School Street SCALE: S:\Projects\2025\251219 - Devine - 37 Hartford Ave., Granby, CT\05 Civil 3D\251219 - SITE.dwg Landscape Architects Civil Engineers · Land Surveyors Environmental Consultants R LEVESQUEASSOCIATES INC 37 Hartford Avenue Granby, CT 06035 Parcel ID: 4254 DRAFTED BY: As Noted R.E.L. May 28, 2026 Mr. Forrest Devine 129 Lovers Lane Granville, MA 01034 251219 PERMITTING NOT FOR CONSTRUCTION SAN-1 - PERC TEST #2 DATA SEPTIC SYSTEM PROFILE NO SCALE PERC TEST #1 DATA DISTRIBUTION BOX DETAIL NO SCALE ≥ ≥ ≥ ≥ GEOMATRIX GST6236 LEACHING SYSTEM - SECTION A-A' GEOMATRIX GST6236 LEACHING SYSTEM - PLAN VIEW ≥ ≥ ≥ GEOMATRIX GST6236 LEACHING SYSTEM - SECTION B-B' GEOMATRIX GST LEACHING SYSTEM - INSPECTION PORT June 10, 2026 SUBSURFACE SEWAGE DISPOSAL SYSTEM PLAN DRAFT
Page 109
HARTFORD AVE WINDMILL DR. SHATTUCK AVE RUSHFORD MEADE BANK ST OAKRIDGE DR SITE BY Site Plans AS PREPARED FOR Proposed Residential Development May 28, 2026 RLA Project Number: 251219 129 Lovers Lane Granville, MA 01034 Mr. Forrest Devine 37 Hartford Avenue Granby, CT 06035 Parcel ID: 4254 40 School Street · Westfield, MA · 01085 ph 413.568.0985 · fax 413.568.0986 www.rlaland.com R LEVESQUE ASSOCIATES INC A LAND PLANNING SERVICES COMPANYR L A DRAWING INDEX SHEET NO. SHEET NAME ISSUE DATE T-1 TITLE SHEET 5/28/26 EX-1 EXISTING CONDITIONS PLAN 5/27/26 C-1 NOTES, SYMBOL & LINE LEGEND, AND ABBREVIATIONS 5/28/26 C-2 CONSTRUCTION NOTES 5/28/26 C-3 DEMOLITION AND REMOVALS PLAN 5/28/26 C-4 LAYOUT AND MATERIALS PLAN 5/28/26 C-5 GRADING, EROSION & SEDIMENTATION CONTROL PLAN 5/28/26 C-6 DRAINAGE AND UTILITIES PLAN 5/28/26 C-7 LANDSCAPING PLAN 5/28/26 SL-1 PHOTOMETRIC PLAN 5/28/26 SL-2 LIGHTING FIXTURE DETAILS 5/28/26 D-1 DETAILS 5/28/26 D-2 DETAILS 5/28/26 D-3 DETAILS 5/28/26 D-4 DETAILS 5/28/26 D-5 DETAILS 5/28/26 PERMITTING NOT FOR CONSTRUCTION
Page 110
p p p p p p p p p p p p p p Hartford Avenue EXISTING FOUNDATION WALLS #41 #35 (CT - Route 189) p p p p p p p p p p p p p p p p p p p p p p p p p p p p p p p p p p p p p p p p p p p p p p Limited Property/Boundary Survey REV. RLA PROJ. NUMBER: DRAWING# OF MASSACHUSETTS STATE LAW THIS DOCUMENT IS A VIOLATION UNAUTHORIZED ALTERATION OF DATE: ISSUANCE DATE: REVISIONS: PREPARED FOR: ph: 413.568.0985 fax: 413.568.0986 rlaland.com Westfield, MA 01085 R L A 40 School Street SCALE: S:\Projects\2025\251219 - Devine - 37 Hartford Ave., Granby, CT\05 Civil 3D\251219 - EXIST.dwg Landscape Architects Civil Engineers · Land Surveyors Environmental Consultants R LEVESQUEASSOCIATES INC DRAFTED BY: As Noted A.Z./J.L. May 27, 2026 251219 37 Hartford Avenue MLBU G-53/78/13 Granby, CT 06035 Forrest Devine 129 Lovers Lane Granville, MA 01034 EX-1 - ZONING REVIEW - Granby Center Zone Commerial Center (COCE) TYPE (MINIMUM) REQUIRED PROPOSED AREA 20,000 SQ FT - FRONTAGE 100 FT - DEPTH 150 FT - FRONT YARD 25 FT -- SIDE YARD 10 FT - REAR YARD 20 FT - HEIGHT (MAX) 3 STORIES (45 FT) - BUILDING COVERAGE (MAX) 30% - pppppp C.S.P.C.S. LOCUS MAP SCALE 1"=1000'
Page 111
NOTES, SYMBOL & LINE LEGEND AND ABBREVIATIONS REV. RLA PROJ. NUMBER: DRAWING# OF MASSACHUSETTS STATE LAW THIS DOCUMENT IS A VIOLATION UNAUTHORIZED ALTERATION OF DATE: ISSUANCE DATE: REVISIONS: PREPARED FOR: ph: 413.568.0985 fax: 413.568.0986 rlaland.com Westfield, MA 01085 R L A 40 School Street SCALE: S:\Projects\2025\251219 - Devine - 37 Hartford Ave., Granby, CT\05 Civil 3D\251219 - SITE.dwg Landscape Architects Civil Engineers · Land Surveyors Environmental Consultants R LEVESQUEASSOCIATES INC 37 Hartford Avenue Granby, CT 06035 Parcel ID: 4254 DRAFTED BY: As Noted R.E.L. May 28, 2026 Mr. Forrest Devine 129 Lovers Lane Granville, MA 01034 251219 PERMITTING NOT FOR CONSTRUCTION C-1 - X pppppp · · · · · · · · · · · · · ·
Page 112
CONSTRUCTION NOTES REV. RLA PROJ. NUMBER: DRAWING# OF MASSACHUSETTS STATE LAW THIS DOCUMENT IS A VIOLATION UNAUTHORIZED ALTERATION OF DATE: ISSUANCE DATE: REVISIONS: PREPARED FOR: ph: 413.568.0985 fax: 413.568.0986 rlaland.com Westfield, MA 01085 R L A 40 School Street SCALE: S:\Projects\2025\251219 - Devine - 37 Hartford Ave., Granby, CT\05 Civil 3D\251219 - SITE.dwg Landscape Architects Civil Engineers · Land Surveyors Environmental Consultants R LEVESQUEASSOCIATES INC 37 Hartford Avenue Granby, CT 06035 Parcel ID: 4254 DRAFTED BY: As Noted R.E.L. May 28, 2026 Mr. Forrest Devine 129 Lovers Lane Granville, MA 01034 251219 PERMITTING NOT FOR CONSTRUCTION C-2 -
Page 113
p p p p p p p p p p p p p p Hartford Avenue EXISTING FOUNDATION WALLS #41 #35 (CT - Route 189) p p p p p p p p p p p p p p p p p p p p p p p p p p p p p p p p p p p p p p p p p p p p p p DEMOLITION & REMOVALS PLAN REV. RLA PROJ. NUMBER: DRAWING# OF MASSACHUSETTS STATE LAW THIS DOCUMENT IS A VIOLATION UNAUTHORIZED ALTERATION OF DATE: ISSUANCE DATE: REVISIONS: PREPARED FOR: ph: 413.568.0985 fax: 413.568.0986 rlaland.com Westfield, MA 01085 R L A 40 School Street SCALE: S:\Projects\2025\251219 - Devine - 37 Hartford Ave., Granby, CT\05 Civil 3D\251219 - SITE.dwg Landscape Architects Civil Engineers · Land Surveyors Environmental Consultants R LEVESQUEASSOCIATES INC 37 Hartford Avenue Granby, CT 06035 Parcel ID: 4254 DRAFTED BY: As Noted R.E.L. May 28, 2026 Mr. Forrest Devine 129 Lovers Lane Granville, MA 01034 251219 PERMITTING NOT FOR CONSTRUCTION C-3 -
Page 114
p p p p p p p p p p p p p p Hartford Avenue (CT - Route 189) p p p p p p p p p p p p p p p p p p p p p p p p p p p p p p p p p p p p p p p p p p p p p p 3-STORY RESIDENTIAL BUILDING ±5,447 S.F. PER STORY STOP LAYOUT & MATERIALS PLAN REV. RLA PROJ. NUMBER: DRAWING# OF MASSACHUSETTS STATE LAW THIS DOCUMENT IS A VIOLATION UNAUTHORIZED ALTERATION OF DATE: ISSUANCE DATE: REVISIONS: PREPARED FOR: ph: 413.568.0985 fax: 413.568.0986 rlaland.com Westfield, MA 01085 R L A 40 School Street SCALE: S:\Projects\2025\251219 - Devine - 37 Hartford Ave., Granby, CT\05 Civil 3D\251219 - SITE.dwg Landscape Architects Civil Engineers · Land Surveyors Environmental Consultants R LEVESQUEASSOCIATES INC 37 Hartford Avenue Granby, CT 06035 Parcel ID: 4254 DRAFTED BY: As Noted R.E.L. May 28, 2026 Mr. Forrest Devine 129 Lovers Lane Granville, MA 01034 251219 PERMITTING NOT FOR CONSTRUCTION C-4 - ZONING REVIEW - COMMERCIAL CENTER (COCE) TYPE (MINIMUM) REQUIRED EXISTING/PROPOSED LOT AREA 20,000 FT2 111,184± FT2 LOT FRONTAGE 100 FT 170± FT LOT DEPTH 150 FT 310± FT FRONT YARD 25 FT 88.6± FT SIDE YARD 10 FT 24.2± FT REAR YARD 20 FT 177.2± FT HEIGHT (MAX) 45 FT (3 STORIES) 3 STORIES BUILDING COVERAGE (MAX) 8,000 FT2 5,447 FT2 LOT COVERAGE (MAX) 30% 22.3% LANDSCAPED AREA (MIN.) 20% 77.7% PARKING 31 33 *PARKING REQUIREMENTS: Multi-Family (2 bedrooms or more) - 2 spaces per unit Thirteen (13) 2-bedroom units x 2 spaces/unit = 26 spaces Multi-Family (1 bedroom) - 1.5 spaces per unit Three (3) 1-bedroom units x 2 spaces/unit = 5 spaces Total Required Parking Spaces = 31 spaces
Page 115
p p p p p p p p p p p p p p Hartford Avenue (CT - Route 189) p p p p p p p p p p p p p p p p p p p p p p p p p p p p p p p p p p p p p p p p p p p p p p 3-STORY RESIDENTIAL BUILDING ±5,447 S.F. PER STORY FIRST STORY F.F.E.=200.50± SECOND STORY F.F.E=213.75± GRADING, EROSION & SEDIMENTATION CONTROL PLAN REV. RLA PROJ. NUMBER: DRAWING# OF MASSACHUSETTS STATE LAW THIS DOCUMENT IS A VIOLATION UNAUTHORIZED ALTERATION OF DATE: ISSUANCE DATE: REVISIONS: PREPARED FOR: ph: 413.568.0985 fax: 413.568.0986 rlaland.com Westfield, MA 01085 R L A 40 School Street SCALE: S:\Projects\2025\251219 - Devine - 37 Hartford Ave., Granby, CT\05 Civil 3D\251219 - SITE.dwg Landscape Architects Civil Engineers · Land Surveyors Environmental Consultants R LEVESQUEASSOCIATES INC 37 Hartford Avenue Granby, CT 06035 Parcel ID: 4254 DRAFTED BY: As Noted R.E.L. May 28, 2026 Mr. Forrest Devine 129 Lovers Lane Granville, MA 01034 251219 PERMITTING NOT FOR CONSTRUCTION C-5 -
Page 116
p p p p p p p p p p p p p p Hartford Avenue (CT - Route 189) p p p p p p p p p p p p p p p p p p p p p p p p p p p p p p p p p p p p p p p p p p p p p p 3-STORY RESIDENTIAL BUILDING ±5,447 S.F. PER STORY E DRAINAGE & UTILITIES PLAN REV. RLA PROJ. NUMBER: DRAWING# OF MASSACHUSETTS STATE LAW THIS DOCUMENT IS A VIOLATION UNAUTHORIZED ALTERATION OF DATE: ISSUANCE DATE: REVISIONS: PREPARED FOR: ph: 413.568.0985 fax: 413.568.0986 rlaland.com Westfield, MA 01085 R L A 40 School Street SCALE: S:\Projects\2025\251219 - Devine - 37 Hartford Ave., Granby, CT\05 Civil 3D\251219 - SITE.dwg Landscape Architects Civil Engineers · Land Surveyors Environmental Consultants R LEVESQUEASSOCIATES INC 37 Hartford Avenue Granby, CT 06035 Parcel ID: 4254 DRAFTED BY: As Noted R.E.L. May 28, 2026 Mr. Forrest Devine 129 Lovers Lane Granville, MA 01034 251219 PERMITTING NOT FOR CONSTRUCTION C-6 -
Page 117
p p p p p p p p p p p p p p Hartford Avenue (CT - Route 189) p p p p p p p p p p p p p p p p p p p p p p p p p p p p p p p p p p p p p p p p p p p p p p 3-STORY RESIDENTIAL BUILDING ±5,447 S.F. PER STORY E STOP SITE LANDSCAPING PLAN REV. RLA PROJ. NUMBER: DRAWING# OF MASSACHUSETTS STATE LAW THIS DOCUMENT IS A VIOLATION UNAUTHORIZED ALTERATION OF DATE: ISSUANCE DATE: REVISIONS: PREPARED FOR: ph: 413.568.0985 fax: 413.568.0986 rlaland.com Westfield, MA 01085 R L A 40 School Street SCALE: S:\Projects\2025\251219 - Devine - 37 Hartford Ave., Granby, CT\05 Civil 3D\251219 - SITE.dwg Landscape Architects Civil Engineers · Land Surveyors Environmental Consultants R LEVESQUEASSOCIATES INC 37 Hartford Avenue Granby, CT 06035 Parcel ID: 4254 DRAFTED BY: As Noted R.E.L. May 28, 2026 Mr. Forrest Devine 129 Lovers Lane Granville, MA 01034 251219 PERMITTING NOT FOR CONSTRUCTION C-7 -
Page 118
Luminaire Schedule QtyLabel Description Tag LLF LuminaireLumens LuminaireWatts TotalWatts 3S4W PROV2-36L-325-3K7-4W 16 FTAG0.900 3813 37.82 113.46 1S5Q PROV2-36L-325-3K7-5Q 16 FTAG0.900 4158 37.82 37.82 1WP4F BEACON: RWL1-48L-10-3K7-4F-UNV 9' FTAG0.900 1232 10.1 10.1 7WP4 BEACON: RWL1-48L-10-3K7-4W-U 9' FTAG0.900 1285 10.1 70.7 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.2 0.3 0.3 0.5 0.5 0.4 0.4 0.3 0.2 0.2 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.5 0.7 0.3 0.9 1.0 1.5 1.4 1.3 1.7 1.1 0.9 0.4 0.6 0.5 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.6 1.3 0.3 1.5 1.9 2.6 2.5 2.4 2.9 2.1 1.7 0.4 1.6 0.8 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.7 1.5 1.8 0.8 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.7 1.3 1.5 0.8 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.2 0.3 0.4 0.3 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.4 0.4 0.4 0.3 0.2 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.3 1.2 0.8 1.2 1.0 1.2 1.0 0.2 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.4 1.0 1.3 1.6 2.3 2.0 1.6 1.4 1.6 1.5 1.5 1.2 1.5 1.0 0.3 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.3 0.5 0.5 1.2 1.6 1.7 1.1 0.7 1.1 1.4 1.1 0.2 1.2 1.0 0.3 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.2 0.4 0.5 0.5 0.5 0.2 0.6 1.4 1.6 1.2 1.6 1.1 0.3 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.2 0.2 0.2 0.2 0.2 0.3 0.4 0.3 0.3 0.6 1.3 1.2 1.1 1.3 1.1 0.3 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.2 0.4 0.5 0.4 0.4 0.5 0.7 0.7 0.6 0.5 0.6 0.7 0.8 0.7 0.6 0.5 0.5 0.4 0.3 0.3 0.3 0.4 0.2 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.4 0.8 1.0 0.8 0.7 0.9 1.2 1.2 1.2 0.9 0.7 0.8 1.0 0.7 0.4 0.5 0.8 0.9 0.7 0.6 0.8 0.8 0.4 0.2 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.4 0.9 1.3 1.1 1.0 1.3 1.4 1.5 1.4 1.2 1.0 1.2 1.2 0.8 0.4 0.5 1.0 1.2 0.9 0.9 1.2 1.0 0.6 0.2 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.4 0.7 1.4 1.5 1.0 1.6 1.3 1.3 1.4 1.6 1.0 1.6 1.2 0.7 0.4 0.5 0.9 1.5 1.5 1.2 1.6 1.0 0.6 0.2 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.2 0.4 0.4 0.4 0.3 0.5 0.3 0.4 0.3 0.4 0.3 0.3 0.2 0.3 0.3 0.5 0.5 0.4 0.6 0.5 0.4 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.2 0.2 0.2 0.1 0.1 0.1 0.2 0.3 0.2 0.1 0.1 0.0 0.1 0.1 0.2 0.3 0.3 0.2 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.1 0.2 0.1 0.1 0.2 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 S4W S4W S4W S5Q WP4 WP4 WP4F WP4 WP4 WP4 WP4 WP4 Sheet 1 of 2 333 Pleasant Valley Road South Windsor, CT 06074 (860) 282-0597 263 Winn Street Burlington, MA 01803 (781) 935-8500 Drawing Number: Detail: Photometric Calculation Date: 05/28/2026 Revision:-- Scale: 1"=20' Drawn By: MGS Project: 37 Hartford Ave Grandby, CT Sheet 1 of 2 SL-1
Page 119
333 Pleasant Valley Road South Windsor, CT 06074 (860) 282-0597 263 Winn Street Burlington, MA 01803 (781) 935-8500 Drawing Number: WP4/W4F - BEACON RATIO WALL S4W / S5Q - VIPER AREA Sheet 2 of 2 SL-2 Detail: Photometric Calculation Date: 05/28/2026 Revision:-- Scale: 1"=20' Drawn By: MGS Project: 37 Hartford Ave Grandby, CT
Page 120
DETAILS REV. RLA PROJ. NUMBER: DRAWING# OF MASSACHUSETTS STATE LAW THIS DOCUMENT IS A VIOLATION UNAUTHORIZED ALTERATION OF DATE: ISSUANCE DATE: REVISIONS: PREPARED FOR: ph: 413.568.0985 fax: 413.568.0986 rlaland.com Westfield, MA 01085 R L A 40 School Street SCALE: S:\Projects\2025\251219 - Devine - 37 Hartford Ave., Granby, CT\05 Civil 3D\251219 - SITE.dwg Landscape Architects Civil Engineers · Land Surveyors Environmental Consultants R LEVESQUEASSOCIATES INC 37 Hartford Avenue Granby, CT 06035 Parcel ID: 4254 DRAFTED BY: As Noted R.E.L. May 28, 2026 Mr. Forrest Devine 129 Lovers Lane Granville, MA 01034 251219 PERMITTING NOT FOR CONSTRUCTION D-1 - SILT FENCE DETAIL SHRUB PLANTING DETAIL TREE PLANTING DETAIL ANTI-TRACKING APRON (AS REQ'D) A A REINFORCED CONCRETE SIDEWALK SECTION INLET PROTECTION - SEDIMENT FILTER SACK MONOLITHIC CONCRETE CURB & SIDEWALK BITUMINOUS CONCRETE PAVING DETAIL INLET PROTECTION - HAY BALES SLOPE PROTECTION MATERIAL INSTALLATION (AS REQ'D) 6" BITUMINOUS CONCRETE LIP CURBING HANDICAP PARKING STALL EROSION CONTROL LOG
Page 121
DETAILS REV. RLA PROJ. NUMBER: DRAWING# OF MASSACHUSETTS STATE LAW THIS DOCUMENT IS A VIOLATION UNAUTHORIZED ALTERATION OF DATE: ISSUANCE DATE: REVISIONS: PREPARED FOR: ph: 413.568.0985 fax: 413.568.0986 rlaland.com Westfield, MA 01085 R L A 40 School Street SCALE: S:\Projects\2025\251219 - Devine - 37 Hartford Ave., Granby, CT\05 Civil 3D\251219 - SITE.dwg Landscape Architects Civil Engineers · Land Surveyors Environmental Consultants R LEVESQUEASSOCIATES INC 37 Hartford Avenue Granby, CT 06035 Parcel ID: 4254 DRAFTED BY: As Noted R.E.L. May 28, 2026 Mr. Forrest Devine 129 Lovers Lane Granville, MA 01034 251219 PERMITTING NOT FOR CONSTRUCTION D-2 - TYPICAL SECTION - SEGMENTAL PRECAST CONCRETE RETAINING WALL LIGHT POLE INSTALLATION DETAIL DUMPSTER ENCLOSURE STEEL BOLLARD WITH SIGN DETAIL 6' STANDARD SINGLE SIDE WHEEL STOP
Page 122
3-STORY RESIDENTIAL BUILDING ±5,447 S.F. PER STORY DETAILS REV. RLA PROJ. NUMBER: DRAWING# OF MASSACHUSETTS STATE LAW THIS DOCUMENT IS A VIOLATION UNAUTHORIZED ALTERATION OF DATE: ISSUANCE DATE: REVISIONS: PREPARED FOR: ph: 413.568.0985 fax: 413.568.0986 rlaland.com Westfield, MA 01085 R L A 40 School Street SCALE: S:\Projects\2025\251219 - Devine - 37 Hartford Ave., Granby, CT\05 Civil 3D\251219 - SITE.dwg Landscape Architects Civil Engineers · Land Surveyors Environmental Consultants R LEVESQUEASSOCIATES INC 37 Hartford Avenue Granby, CT 06035 Parcel ID: 4254 DRAFTED BY: As Noted R.E.L. May 28, 2026 Mr. Forrest Devine 129 Lovers Lane Granville, MA 01034 251219 PERMITTING NOT FOR CONSTRUCTION D-3 - OUTLET CONTROL STRUCTURE (POCS-1) INLET CONTROL STRUCTURE (PICS-1) SUBSURFACE INFILTRATION BASIN CATCH BASIN OR MANHOLE SC-800 END CAP OPTIONAL INSPECTION PORT SC-800 CHAMBER ONE LAYER OF ADSPLUS625 WOVEN GEOTEXTILE BETWEEN FOUNDATION STONE AND CHAMBERS 5' MIN WIDE CONTINUOUS FABRIC WITHOUT SEAMS 24" (600 mm) HDPE ACCESS PIPE REQUIRED USE END CAP PART #: SC800ECEZ STORMTECH HIGHLY RECOMMENDS FLEXSTORM INSERTS IN ANY UPSTREAM STRUCTURES WITH OPEN GRATES SUMP DEPTH TBD BY SITE DESIGN ENGINEER (24" MIN RECOMMENDED) INSTALL FLAMP ON 24" (600 mm) ACESS PIPE PART #: SC80024RAMP ELEVATED BYPASS MANIFOLD 12" (300 mm) MIN 12" MIN51"3" MINSUBGRADE SOILS (SEE MANUFACTURER'S RECOMMENDATION) PAVEMENT LAYER (DESIGNED BY SITE DESIGN ENGINEER) 8' MAX ADS GEOSYNTHETICS 601T NON-WOVEN GEOTEXTILE ALL AROUND CLEAN, CRUSHED, ANGULAR STONE *TO BOTTOM OF FLEXIBLE PAVEMENT. FOR UNPAVED INSTALLATIONS WHERE RUTTING FROM VEHICLES MAY OCCUR, INCREASE COVER TO 21". 15" 6" MIN EXCAVATION WALL (CAN BE SLOPED OR VERTICAL) PERIMETER STONE (SEE MANUFACTURER'S RECOMMENDATION) SC-800 END CAP 33" 6" MIN GRANULAR WELL GRADED SOIL/AGGREGATE MIXTURES, <35% FINES. COMPACT IN 6" LIFTS TO 95% STANDARD PROCTOR DENSITY. SEE THE TABLE OF ACCEPTABLE FILL MATERIALS. STORMTECH SC-800 ISOLATOR ROW DETAIL STORMTECH SC-800 CROSS-SECTION NOTE: INSPECTION PORTS MAY BE CONNECTED THROUGH ANY CHAMBER CORRUGATION CREST. STORMTECH CHAMBER 8" NYLOPLAST UNIVERSAL INLINE DRAIN BODY (PART# 2708AG4IPKIT) OR TRAFFIC RATED BOX W/SOLID LOCKING COVER CONCRETE COLLAR ASPHALT OVERLAY FOR TRAFFIC APPLICATIONS 12" MIN WIDTH 8" MIN THICKNESS OF ASPHALT OVERLAY AND CONCRETE COLLAR CONCRETE COLLAR / ASPHALT OVERLAY NOT REQUIRED FOR GREENSPACE OR NON-TRAFFIC APPLICATIONS 4" SDR 35 PIPE 4" INSERTA TEE TO BE CENTERED ON CORRUGATION CREST NYLOPLAST 8" LOCKING SOLID COVER AND FRAME INSERTA TEE DETAIL NTS INSERTA TEE CONNECTION CONVEYANCE PIPE MATERIAL MAY VARY (PVC, HDPE, ETC.) PLACE ADSPLUS WOVEN GEOTEXTILE (CENTERED ON INSERTA-TEE INLET) OVER BEDDING STONE FOR SCOUR PROTECTION AT SIDE INLET CONNECTIONS. GEOTEXTILE MUST EXTEND 6" PAST CHAMBER FOOT INSERTA TEE TO BE INSTALLED, CENTERED OVER CORRUGATION SIDE VIEWSECTION A-A A A DO NOT INSTALL INSERTA-TEE AT CHAMBER JOINTS NOTES: · PART NUMBERS WILL VARY BASED ON INLET PIPE MATERIALS. CONTACT STORMTECH FOR MORE INFORMATION. · CONTACT ADS ENGINEERING SERVICES IF INSERTA TEE INLET MUST BE RAISED AS NOT ALL INVERTS ARE POSSIBLE. CHAMBER MAX DIAMETER OF INSERTA TEE HEIGHT FROM BASE OF CHAMBER (X) SC-310 6" (150 mm) 4" (100 mm) SC-800 10" (250 mm) 4" (100 mm) DC-780 10" (250 mm) 4" (100 mm) MC-3500 12" (300 mm) 6" (150 mm) MC-4500 12" (300 mm) 8" (200 mm) MC-7200 12" (300 mm) 8" (200 mm) INSERTA TEE FITTINGS AVAILABLE FOR SDR 26, SDR 35, SCH 40 IPS GASKETED & SOLVENT WELD, N-12, HP STORM, C-900 OR DUCTILE IRON (X) STORMTECH SC-800 INSPECTION PORT DETAIL STORMTECH INSERTA-TEE SIDE INLET DETAIL
Page 123
DETAILS REV. RLA PROJ. NUMBER: DRAWING# OF MASSACHUSETTS STATE LAW THIS DOCUMENT IS A VIOLATION UNAUTHORIZED ALTERATION OF DATE: ISSUANCE DATE: REVISIONS: PREPARED FOR: ph: 413.568.0985 fax: 413.568.0986 rlaland.com Westfield, MA 01085 R L A 40 School Street SCALE: S:\Projects\2025\251219 - Devine - 37 Hartford Ave., Granby, CT\05 Civil 3D\251219 - SITE.dwg Landscape Architects Civil Engineers · Land Surveyors Environmental Consultants R LEVESQUEASSOCIATES INC 37 Hartford Avenue Granby, CT 06035 Parcel ID: 4254 DRAFTED BY: As Noted R.E.L. May 28, 2026 Mr. Forrest Devine 129 Lovers Lane Granville, MA 01034 251219 PERMITTING NOT FOR CONSTRUCTION D-4 - (36" MIN) 7.08' 12" (MIN) 7.00'(MIN.) [84.0"] WATER QUALITY UNIT - BARRACUDA S4 (PWQU-1) VARIABLE OUTLET LOCATIONS VARIABLE INLET LOCATIONS DOWNSPOUT COLLECTOR DETAIL PRECAST CONCRETE CATCH BASIN ADS NYLOPLAST YARD DRAIN BASIN STANDARD DRAINAGE MANHOLE DETAIL
Page 124
DETAILS REV. RLA PROJ. NUMBER: DRAWING# OF MASSACHUSETTS STATE LAW THIS DOCUMENT IS A VIOLATION UNAUTHORIZED ALTERATION OF DATE: ISSUANCE DATE: REVISIONS: PREPARED FOR: ph: 413.568.0985 fax: 413.568.0986 rlaland.com Westfield, MA 01085 R L A 40 School Street SCALE: S:\Projects\2025\251219 - Devine - 37 Hartford Ave., Granby, CT\05 Civil 3D\251219 - SITE.dwg Landscape Architects Civil Engineers · Land Surveyors Environmental Consultants R LEVESQUEASSOCIATES INC 37 Hartford Avenue Granby, CT 06035 Parcel ID: 4254 DRAFTED BY: As Noted R.E.L. May 28, 2026 Mr. Forrest Devine 129 Lovers Lane Granville, MA 01034 251219 PERMITTING NOT FOR CONSTRUCTION D-5 -
Page 125
Page 126
Page 127
............................................................................................................................ 1-3 .................................................................................................................... 2-4 ................................................................................................... 2-4 .......................................................................................................................... 2-4 ................................................................................................................................... 2-4 ....................................................................................... 2-5 ........................................................................................................ 2-5 ............................................................................................................................................... 2-5 ................................................................................................ 2-6 ........................................................................ 3-7 ............................................................................................................. 3-7 .............................................................................................................................. 3-8 .................................................................................................. 3-8 ................................................................................................ 3-8 ............................................................................................................... 3-9 ..................................................................................................................... 3-9 .................................................................. 3-9 ........................................................................... 3-11 ..................................................................................... 3-11 ..................................................................................... 3-11 ............................................................................................... 3-12 ........... 3-12 ............... 3-12 ............................................................................ 3-12 .......................................... 3-12 .............................................................................................................................. 4-13 ............................................................................................................. 2-5 ........................................................................................................................................... 3-7 ................................................................................... 3-9
Page 128
Page 129
Page 130
Page 131
Page 132
Page 133
Page 134
Page 135
Page 136
Page 137
Page 138
Page 139
Page 140
Page 141
Page 142
Page 143
SITE R L A SCALE: DATE: JOB NO: ph: 413.568.0985 fax: 413.568.0986 rlaland.com 40 School Street · P.O. Box 640 · Westfield, MA 01086 R LEVESQUE ASSOCIATES, INC A Land Planning Services Company 251219 5/28/2026 As noted Mr. Forrest Devine 129 Lovers Lane Granville, Massachusetts 01034 Proposed Residential Development 37 Hartford Avenue Granby, Connecticut 06035R L A SCALE: DATE: JOB NO: ph: 413.568.0985 fax: 413.568.0986 rlaland.com 40 School Street · P.O. Box 640 · Westfield, MA 01086 R LEVESQUE ASSOCIATES, INC A Land Planning Services Company 251219 5/28/2026 As noted Mr. Forrest Devine 129 Lovers Lane Granville, Massachusetts 01034 Proposed Residential Development 37 Hartford Avenue Granby, Connecticut 06035 FIG-1 SITE LOCUS USGS MAP
Page 144
Page 145
Page 146
Page 147
SITE R L A SCALE: DATE: JOB NO: ph: 413.568.0985 fax: 413.568.0986 rlaland.com 40 School Street · P.O. Box 640 · Westfield, MA 01086 R LEVESQUE ASSOCIATES, INC A Land Planning Services Company 251219 5/28/2026 As noted Mr. Forrest Devine 129 Lovers Lane Granville, Massachusetts 01034 Proposed Residential Development 37 Hartford Avenue Granby, Connecticut 06035 FIG-2 FEMA FLOOD MAP Flood Zone Boundary
Page 148
Page 149
Page 150
Page 151
SITE CRITICAL HABITAT R L A SCALE: DATE: JOB NO: ph: 413.568.0985 fax: 413.568.0986 rlaland.com 40 School Street · P.O. Box 640 · Westfield, MA 01086 R LEVESQUE ASSOCIATES, INC A Land Planning Services Company 251219 5/28/2026 As noted Mr. Forrest Devine 129 Lovers Lane Granville, Massachusetts 01034 Proposed Residential Development 37 Hartford Avenue Granby, Connecticut 06035 FIG-3 NDDB Map NDDB Area
Page 152
Page 153
Page 154
Page 155
SITE R L A SCALE: DATE: JOB NO: ph: 413.568.0985 fax: 413.568.0986 rlaland.com 40 School Street · P.O. Box 640 · Westfield, MA 01086 R LEVESQUE ASSOCIATES, INC A Land Planning Services Company 251219 5/28/2026 As noted Mr. Forrest Devine 129 Lovers Lane Granville, Massachusetts 01034 Proposed Residential Development 37 Hartford Avenue Granby, Connecticut 06035 FIG-4 Aquifer Protection Area Map Aquifer Protection Area
Page 156
Page 157
Page 158
Page 159
Hartford Avenue EXISTING FOUNDATION WALLS #41 #35 (CT - Route 189) p p p p p p p p p p p p p p p p p p p p p p p 29A Agawam Fine Sandy Loam Hydrologic Group: B 38E Hinckley Loamy Sand Hydrologic Group: A SCALE: DATE: JOB NO.: ph: 413.568.0985 fax: 413.568.0986 rlaland.com 40 School Street · P.O. Box 640 · Westfield, MA 01086 R LEVESQUE ASSOCIATES, INC A Land Planning Services CompanyPre-Development Area Plan Proposed Residential Development 37 Hartford Avenue Granby, CT 06035 Mr. Forrest Devine 129 Lovers Lane Granville, MA 01034 251219 5/28/26 As Noted FIG-5
Page 160
Page 161
Page 162
Page 163
Hartford Avenue EXISTING FOUNDATION WALLS #41 #35 (CT - Route 189) p p p p p p p p p p p p p p p p p p p p p p p 3-STORY RESIDENTIAL BUILDING ±5,447 S.F. PER STORY 29A Agawam Fine Sandy Loam Hydrologic Group: B 38E Hinckley Loamy Sand Hydrologic Group: A SCALE: DATE: JOB NO.: ph: 413.568.0985 fax: 413.568.0986 rlaland.com 40 School Street · P.O. Box 640 · Westfield, MA 01086 R LEVESQUE ASSOCIATES, INC A Land Planning Services CompanyPost-Development Area Plan Proposed Residential Development 37 Hartford Avenue Granby, CT 06035 Mr. Forrest Devine 129 Lovers Lane Granville, MA 01034 251219 5/28/26 As Noted FIG-6
Page 164
Page 165
Page 166
Page 167
Hartford Avenue EXISTING FOUNDATION WALLS #41 #35 (CT - Route 189) p p p p p p p p p p p p p p p p p p p p p p p 3-STORY RESIDENTIAL BUILDING ±5,447 S.F. PER STORY 29A Agawam Fine Sandy Loam Hydrologic Group: B 38E Hinckley Loamy Sand Hydrologic Group: A SCALE: DATE: JOB NO.: ph: 413.568.0985 fax: 413.568.0986 rlaland.com 40 School Street · P.O. Box 640 · Westfield, MA 01086 R LEVESQUE ASSOCIATES, INC A Land Planning Services CompanyInlet Area Plan Proposed Residential Development 37 Hartford Avenue Granby, CT 06035 Mr. Forrest Devine 129 Lovers Lane Granville, MA 01034 251219 5/28/26 As Noted FIG-7
Page 168
Page 169
Page 170
Page 171
United States Department of Agriculture A product of the National Cooperative Soil Survey, a joint effort of the United States Department of Agriculture and other Federal agencies, State agencies including the Agricultural Experiment Stations, and local participants Custom Soil Resource Report for State of Connecticut, Western Part Natural Resources Conservation Service May 11, 2026
Page 172
Preface Soil surveys contain information that affects land use planning in survey areas. They highlight soil limitations that affect various land uses and provide information about the properties of the soils in the survey areas. Soil surveys are designed for many different users, including farmers, ranchers, foresters, agronomists, urban planners, community officials, engineers, developers, builders, and home buyers. Also, conservationists, teachers, students, and specialists in recreation, waste disposal, and pollution control can use the surveys to help them understand, protect, or enhance the environment. Various land use regulations of Federal, State, and local governments may impose special restrictions on land use or land treatment. Soil surveys identify soil properties that are used in making various land use or land treatment decisions. The information is intended to help the land users identify and reduce the effects of soil limitations on various land uses. The landowner or user is responsible for identifying and complying with existing laws and regulations. Although soil survey information can be used for general farm, local, and wider area planning, onsite investigation is needed to supplement this information in some cases. Examples include soil quality assessments (http://www.nrcs.usda.gov/wps/ portal/nrcs/main/soils/health/) and certain conservation and engineering applications. For more detailed information, contact your local USDA Service Center (https://offices.sc.egov.usda.gov/locator/app?agency=nrcs) or your NRCS State Soil Scientist (http://www.nrcs.usda.gov/wps/portal/nrcs/detail/soils/contactus/? cid=nrcs142p2_053951). Great differences in soil properties can occur within short distances. Some soils are seasonally wet or subject to flooding. Some are too unstable to be used as a foundation for buildings or roads. Clayey or wet soils are poorly suited to use as septic tank absorption fields. A high water table makes a soil poorly suited to basements or underground installations. The National Cooperative Soil Survey is a joint effort of the United States Department of Agriculture and other Federal agencies, State agencies including the Agricultural Experiment Stations, and local agencies. The Natural Resources Conservation Service (NRCS) has leadership for the Federal part of the National Cooperative Soil Survey. Information about soils is updated periodically. Updated information is available through the NRCS Web Soil Survey, the site for official soil survey information. The U.S. Department of Agriculture (USDA) prohibits discrimination in all its programs and activities on the basis of race, color, national origin, age, disability, and where applicable, sex, marital status, familial status, parental status, religion, sexual orientation, genetic information, political beliefs, reprisal, or because all or a part of an individual's income is derived from any public assistance program. (Not all prohibited bases apply to all programs.) Persons with disabilities who require 2
Page 173
alternative means for communication of program information (Braille, large print, audiotape, etc.) should contact USDA's TARGET Center at (202) 720-2600 (voice and TDD). To file a complaint of discrimination, write to USDA, Director, Office of Civil Rights, 1400 Independence Avenue, S.W., Washington, D.C. 20250-9410 or call (800) 795-3272 (voice) or (202) 720-6382 (TDD). USDA is an equal opportunity provider and employer. 3
Page 174
Contents Preface.................................................................................................................... 2 How Soil Surveys Are Made..................................................................................5 Soil Map.................................................................................................................. 8 Soil Map................................................................................................................9 Legend................................................................................................................10 Map Unit Legend................................................................................................ 11 Map Unit Descriptions.........................................................................................11 State of Connecticut, Western Part.................................................................13 29A—Agawam fine sandy loam, 0 to 3 percent slopes...............................13 38E—Hinckley loamy sand, 15 to 45 percent slopes..................................14 References............................................................................................................17 4
Page 175
How Soil Surveys Are Made Soil surveys are made to provide information about the soils and miscellaneous areas in a specific area. They include a description of the soils and miscellaneous areas and their location on the landscape and tables that show soil properties and limitations affecting various uses. Soil scientists observed the steepness, length, and shape of the slopes; the general pattern of drainage; the kinds of crops and native plants; and the kinds of bedrock. They observed and described many soil profiles. A soil profile is the sequence of natural layers, or horizons, in a soil. The profile extends from the surface down into the unconsolidated material in which the soil formed or from the surface down to bedrock. The unconsolidated material is devoid of roots and other living organisms and has not been changed by other biological activity. Currently, soils are mapped according to the boundaries of major land resource areas (MLRAs). MLRAs are geographically associated land resource units that share common characteristics related to physiography, geology, climate, water resources, soils, biological resources, and land uses (USDA, 2006). Soil survey areas typically consist of parts of one or more MLRA. The soils and miscellaneous areas in a survey area occur in an orderly pattern that is related to the geology, landforms, relief, climate, and natural vegetation of the area. Each kind of soil and miscellaneous area is associated with a particular kind of landform or with a segment of the landform. By observing the soils and miscellaneous areas in the survey area and relating their position to specific segments of the landform, a soil scientist develops a concept, or model, of how they were formed. Thus, during mapping, this model enables the soil scientist to predict with a considerable degree of accuracy the kind of soil or miscellaneous area at a specific location on the landscape. Commonly, individual soils on the landscape merge into one another as their characteristics gradually change. To construct an accurate soil map, however, soil scientists must determine the boundaries between the soils. They can observe only a limited number of soil profiles. Nevertheless, these observations, supplemented by an understanding of the soil-vegetation-landscape relationship, are sufficient to verify predictions of the kinds of soil in an area and to determine the boundaries. Soil scientists recorded the characteristics of the soil profiles that they studied. They noted soil color, texture, size and shape of soil aggregates, kind and amount of rock fragments, distribution of plant roots, reaction, and other features that enable them to identify soils. After describing the soils in the survey area and determining their properties, the soil scientists assigned the soils to taxonomic classes (units). Taxonomic classes are concepts. Each taxonomic class has a set of soil characteristics with precisely defined limits. The classes are used as a basis for comparison to classify soils systematically. Soil taxonomy, the system of taxonomic classification used in the United States, is based mainly on the kind and character of soil properties and the arrangement of horizons within the profile. After the soil 5
Page 176
scientists classified and named the soils in the survey area, they compared the individual soils with similar soils in the same taxonomic class in other areas so that they could confirm data and assemble additional data based on experience and research. The objective of soil mapping is not to delineate pure map unit components; the objective is to separate the landscape into landforms or landform segments that have similar use and management requirements. Each map unit is defined by a unique combination of soil components and/or miscellaneous areas in predictable proportions. Some components may be highly contrasting to the other components of the map unit. The presence of minor components in a map unit in no way diminishes the usefulness or accuracy of the data. The delineation of such landforms and landform segments on the map provides sufficient information for the development of resource plans. If intensive use of small areas is planned, onsite investigation is needed to define and locate the soils and miscellaneous areas. Soil scientists make many field observations in the process of producing a soil map. The frequency of observation is dependent upon several factors, including scale of mapping, intensity of mapping, design of map units, complexity of the landscape, and experience of the soil scientist. Observations are made to test and refine the soil-landscape model and predictions and to verify the classification of the soils at specific locations. Once the soil-landscape model is refined, a significantly smaller number of measurements of individual soil properties are made and recorded. These measurements may include field measurements, such as those for color, depth to bedrock, and texture, and laboratory measurements, such as those for content of sand, silt, clay, salt, and other components. Properties of each soil typically vary from one point to another across the landscape. Observations for map unit components are aggregated to develop ranges of characteristics for the components. The aggregated values are presented. Direct measurements do not exist for every property presented for every map unit component. Values for some properties are estimated from combinations of other properties. While a soil survey is in progress, samples of some of the soils in the area generally are collected for laboratory analyses and for engineering tests. Soil scientists interpret the data from these analyses and tests as well as the field-observed characteristics and the soil properties to determine the expected behavior of the soils under different uses. Interpretations for all of the soils are field tested through observation of the soils in different uses and under different levels of management. Some interpretations are modified to fit local conditions, and some new interpretations are developed to meet local needs. Data are assembled from other sources, such as research information, production records, and field experience of specialists. For example, data on crop yields under defined levels of management are assembled from farm records and from field or plot experiments on the same kinds of soil. Predictions about soil behavior are based not only on soil properties but also on such variables as climate and biological activity. Soil conditions are predictable over long periods of time, but they are not predictable from year to year. For example, soil scientists can predict with a fairly high degree of accuracy that a given soil will have a high water table within certain depths in most years, but they cannot predict that a high water table will always be at a specific level in the soil on a specific date. After soil scientists located and identified the significant natural bodies of soil in the survey area, they drew the boundaries of these bodies on aerial photographs and Custom Soil Resource Report 6
Page 177
identified each as a specific map unit. Aerial photographs show trees, buildings, fields, roads, and rivers, all of which help in locating boundaries accurately. Custom Soil Resource Report 7
Page 178
Soil Map The soil map section includes the soil map for the defined area of interest, a list of soil map units on the map and extent of each map unit, and cartographic symbols displayed on the map. Also presented are various metadata about data used to produce the map, and a description of each soil map unit. 8
Page 179
9 Custom Soil Resource Report Soil Map 4646400 4646420 4646440 4646460 4646480 4646500 4646520 4646540 4646560 4646580 4646420 4646440 4646460 4646480 4646500 4646520 4646540 4646560 4646580 683580 683600 683620 683640 683660 683680 683700 683580 683600 683620 683640 683660 683680 683700 41° 56' 59'' N 72° 47' 6'' W 41° 56' 59'' N 72° 47' 0'' W 41° 56' 53'' N 72° 47' 6'' W 41° 56' 53'' N 72° 47' 0'' WN Map projection: Web Mercator Corner coordinates: WGS84 Edge tics: UTM Zone 18N WGS84 0 40 80 160 240 Feet 0 10 20 40 60 Meters Map Scale: 1:910 if printed on A portrait (8.5" x 11") sheet. Soil Map may not be valid at this scale.
Page 180
MAP LEGEND MAP INFORMATION Area of Interest (AOI) Area of Interest (AOI) Soils Soil Map Unit Polygons Soil Map Unit Lines Soil Map Unit Points Special Point Features Blowout Borrow Pit Clay Spot Closed Depression Gravel Pit Gravelly Spot Landfill Lava Flow Marsh or swamp Mine or Quarry Miscellaneous Water Perennial Water Rock Outcrop Saline Spot Sandy Spot Severely Eroded Spot Sinkhole Slide or Slip Sodic Spot Spoil Area Stony Spot Very Stony Spot Wet Spot Other Special Line Features Water Features Streams and Canals Transportation Rails Interstate Highways US Routes Major Roads Local Roads Background Aerial Photography The soil surveys that comprise your AOI were mapped at 1:12,000. Warning: Soil Map may not be valid at this scale. Enlargement of maps beyond the scale of mapping can cause misunderstanding of the detail of mapping and accuracy of soil line placement. The maps do not show the small areas of contrasting soils that could have been shown at a more detailed scale. Please rely on the bar scale on each map sheet for map measurements. Source of Map: Natural Resources Conservation Service Web Soil Survey URL: Coordinate System: Web Mercator (EPSG:3857) Maps from the Web Soil Survey are based on the Web Mercator projection, which preserves direction and shape but distorts distance and area. A projection that preserves area, such as the Albers equal-area conic projection, should be used if more accurate calculations of distance or area are required. This product is generated from the USDA-NRCS certified data as of the version date(s) listed below. Soil Survey Area: State of Connecticut, Western Part Survey Area Data: Version 6, Sep 16, 2025 Soil map units are labeled (as space allows) for map scales 1:50,000 or larger. Date(s) aerial images were photographed: Jun 14, 2022—Oct 6, 2022 The orthophoto or other base map on which the soil lines were compiled and digitized probably differs from the background imagery displayed on these maps. As a result, some minor shifting of map unit boundaries may be evident. Custom Soil Resource Report 10
Page 181
Map Unit Legend Map Unit Symbol Map Unit Name Acres in AOI Percent of AOI 29A Agawam fine sandy loam, 0 to 3 percent slopes 1.0 47.2% 38E Hinckley loamy sand, 15 to 45 percent slopes 1.1 52.8% Totals for Area of Interest 2.1 100.0% Map Unit Descriptions The map units delineated on the detailed soil maps in a soil survey represent the soils or miscellaneous areas in the survey area. The map unit descriptions, along with the maps, can be used to determine the composition and properties of a unit. A map unit delineation on a soil map represents an area dominated by one or more major kinds of soil or miscellaneous areas. A map unit is identified and named according to the taxonomic classification of the dominant soils. Within a taxonomic class there are precisely defined limits for the properties of the soils. On the landscape, however, the soils are natural phenomena, and they have the characteristic variability of all natural phenomena. Thus, the range of some observed properties may extend beyond the limits defined for a taxonomic class. Areas of soils of a single taxonomic class rarely, if ever, can be mapped without including areas of other taxonomic classes. Consequently, every map unit is made up of the soils or miscellaneous areas for which it is named and some minor components that belong to taxonomic classes other than those of the major soils. Most minor soils have properties similar to those of the dominant soil or soils in the map unit, and thus they do not affect use and management. These are called noncontrasting, or similar, components. They may or may not be mentioned in a particular map unit description. Other minor components, however, have properties and behavioral characteristics divergent enough to affect use or to require different management. These are called contrasting, or dissimilar, components. They generally are in small areas and could not be mapped separately because of the scale used. Some small areas of strongly contrasting soils or miscellaneous areas are identified by a special symbol on the maps. If included in the database for a given area, the contrasting minor components are identified in the map unit descriptions along with some characteristics of each. A few areas of minor components may not have been observed, and consequently they are not mentioned in the descriptions, especially where the pattern was so complex that it was impractical to make enough observations to identify all the soils and miscellaneous areas on the landscape. The presence of minor components in a map unit in no way diminishes the usefulness or accuracy of the data. The objective of mapping is not to delineate pure taxonomic classes but rather to separate the landscape into landforms or landform segments that have similar use and management requirements. The delineation of such segments on the map provides sufficient information for the development of resource plans. If intensive use of small areas is planned, however, Custom Soil Resource Report 11
Page 182
onsite investigation is needed to define and locate the soils and miscellaneous areas. An identifying symbol precedes the map unit name in the map unit descriptions. Each description includes general facts about the unit and gives important soil properties and qualities. Soils that have profiles that are almost alike make up a soil series. Except for differences in texture of the surface layer, all the soils of a series have major horizons that are similar in composition, thickness, and arrangement. Soils of one series can differ in texture of the surface layer, slope, stoniness, salinity, degree of erosion, and other characteristics that affect their use. On the basis of such differences, a soil series is divided into soil phases. Most of the areas shown on the detailed soil maps are phases of soil series. The name of a soil phase commonly indicates a feature that affects use or management. For example, Alpha silt loam, 0 to 2 percent slopes, is a phase of the Alpha series. Some map units are made up of two or more major soils or miscellaneous areas. These map units are complexes, associations, or undifferentiated groups. A complex consists of two or more soils or miscellaneous areas in such an intricate pattern or in such small areas that they cannot be shown separately on the maps. The pattern and proportion of the soils or miscellaneous areas are somewhat similar in all areas. Alpha-Beta complex, 0 to 6 percent slopes, is an example. An association is made up of two or more geographically associated soils or miscellaneous areas that are shown as one unit on the maps. Because of present or anticipated uses of the map units in the survey area, it was not considered practical or necessary to map the soils or miscellaneous areas separately. The pattern and relative proportion of the soils or miscellaneous areas are somewhat similar. Alpha-Beta association, 0 to 2 percent slopes, is an example. An undifferentiated group is made up of two or more soils or miscellaneous areas that could be mapped individually but are mapped as one unit because similar interpretations can be made for use and management. The pattern and proportion of the soils or miscellaneous areas in a mapped area are not uniform. An area can be made up of only one of the major soils or miscellaneous areas, or it can be made up of all of them. Alpha and Beta soils, 0 to 2 percent slopes, is an example. Some surveys include miscellaneous areas. Such areas have little or no soil material and support little or no vegetation. Rock outcrop is an example. Custom Soil Resource Report 12
Page 183
State of Connecticut, Western Part 29A—Agawam fine sandy loam, 0 to 3 percent slopes Map Unit Setting National map unit symbol: 2tyqw Landscape: Valleys, outwash plains Elevation: 0 to 1,040 feet Mean annual precipitation: 36 to 71 inches Mean annual air temperature: 39 to 55 degrees F Frost-free period: 140 to 250 days Farmland classification: All areas are prime farmland Map Unit Composition Agawam and similar soils: 85 percent Minor components: 15 percent Estimates are based on observations, descriptions, and transects of the mapunit. Description of Agawam Setting Landscape: Valleys, outwash plains Landform: Moraines, Kames, Kame terraces, Outwash plains, Outwash terraces Landform position (two-dimensional): Summit, shoulder, backslope, footslope Landform position (three-dimensional): Side slope, crest, riser, tread, rise, dip Down-slope shape: Convex Across-slope shape: Convex Parent material: Coarse-loamy eolian deposits over sandy and gravelly glaciofluvial deposits derived from gneiss, granite, schist, and/or phyllite Typical profile Ap - 0 to 11 inches: fine sandy loam Bw1 - 11 to 16 inches: fine sandy loam Bw2 - 16 to 26 inches: fine sandy loam 2C1 - 26 to 39 inches: loamy fine sand 2C2 - 39 to 55 inches: loamy fine sand 2C3 - 55 to 65 inches: loamy sand Properties and qualities Slope: 0 to 3 percent Depth to restrictive feature: 15 to 35 inches to strongly contrasting textural stratification Drainage class: Well drained Runoff class: Very low Capacity of the most limiting layer to transmit water (Ksat): Moderately low to high (0.14 to 14.17 in/hr) Depth to water table: More than 80 inches Frequency of flooding: None Frequency of ponding: None Maximum salinity: Nonsaline (0.0 to 1.9 mmhos/cm) Available water supply, 0 to 60 inches: Low (about 3.4 inches) Interpretive groups Land capability classification (irrigated): None specified Land capability classification (nonirrigated): 2s Custom Soil Resource Report 13
Page 184
Hydrologic Soil Group: B Ecological site: F145XY008MA - Dry Outwash Hydric soil rating: No Minor Components Ninigret Percent of map unit: 5 percent Landscape: Valleys Landform: Terraces Down-slope shape: Linear Across-slope shape: Concave Hydric soil rating: No Windsor Percent of map unit: 4 percent Landscape: Valleys Landform: Dunes, Deltas, Outwash terraces, Outwash plains Landform position (three-dimensional): Tread, riser Down-slope shape: Convex, linear Across-slope shape: Convex, linear Hydric soil rating: No Walpole Percent of map unit: 3 percent Landscape: Outwash plains Landform: Deltas, Depressions, Outwash terraces, Depressions, Outwash plains Landform position (two-dimensional): Toeslope Landform position (three-dimensional): Tread, talf, dip Down-slope shape: Concave Across-slope shape: Concave Hydric soil rating: Yes Hinckley Percent of map unit: 3 percent Landscape: Outwash plains, valleys Landform: Deltas, Kames, Eskers, Outwash plains Landform position (two-dimensional): Summit, shoulder, backslope Landform position (three-dimensional): Head slope, nose slope, side slope, crest, rise Down-slope shape: Convex Across-slope shape: Convex, linear Hydric soil rating: No 38E—Hinckley loamy sand, 15 to 45 percent slopes Map Unit Setting National map unit symbol: 2svmj Landscape: Uplands, valleys Elevation: 0 to 1,280 feet Mean annual precipitation: 36 to 71 inches Custom Soil Resource Report 14
Page 185
Mean annual air temperature: 39 to 55 degrees F Frost-free period: 140 to 240 days Farmland classification: Not prime farmland Map Unit Composition Hinckley and similar soils: 85 percent Minor components: 15 percent Estimates are based on observations, descriptions, and transects of the mapunit. Description of Hinckley Setting Landscape: Uplands, valleys Landform: Eskers, Kames, Outwash deltas, Outwash terraces, Moraines, Outwash plains, Kame terraces Landform position (two-dimensional): Backslope Landform position (three-dimensional): Head slope, nose slope, side slope, crest, riser Down-slope shape: Concave, convex, linear Across-slope shape: Convex, linear, concave Parent material: Sandy and gravelly glaciofluvial deposits derived from gneiss and/or granite and/or schist Typical profile Oe - 0 to 1 inches: moderately decomposed plant material A - 1 to 8 inches: loamy sand Bw1 - 8 to 11 inches: gravelly loamy sand Bw2 - 11 to 16 inches: gravelly loamy sand BC - 16 to 19 inches: very gravelly loamy sand C - 19 to 65 inches: very gravelly sand Properties and qualities Slope: 15 to 45 percent Depth to restrictive feature: More than 80 inches Drainage class: Excessively drained Runoff class: Low Capacity of the most limiting layer to transmit water (Ksat): Moderately high to very high (1.42 to 99.90 in/hr) Depth to water table: More than 80 inches Frequency of flooding: None Frequency of ponding: None Maximum salinity: Nonsaline (0.0 to 1.9 mmhos/cm) Available water supply, 0 to 60 inches: Low (about 3.1 inches) Interpretive groups Land capability classification (irrigated): None specified Land capability classification (nonirrigated): 7e Hydrologic Soil Group: A Ecological site: F144AY022MA - Dry Outwash Hydric soil rating: No Minor Components Windsor Percent of map unit: 5 percent Landscape: Uplands, valleys Custom Soil Resource Report 15
Page 186
Landform: Eskers, Kames, Moraines, Outwash deltas, Outwash terraces, Outwash plains, Kame terraces Landform position (two-dimensional): Backslope Landform position (three-dimensional): Head slope, nose slope, side slope, crest, riser Down-slope shape: Concave, convex, linear Across-slope shape: Convex, linear, concave Hydric soil rating: No Merrimac Percent of map unit: 5 percent Landscape: Valleys, outwash plains Landform: Outwash plains, Outwash terraces, Moraines, Eskers, Kames Landform position (two-dimensional): Backslope Landform position (three-dimensional): Head slope, nose slope, side slope, crest, riser Down-slope shape: Convex Across-slope shape: Convex Hydric soil rating: No Agawam Percent of map unit: 3 percent Landscape: Uplands, valleys Landform: Eskers, Kame terraces, Outwash deltas, Outwash terraces, Moraines, Kames, Outwash plains Landform position (two-dimensional): Backslope Landform position (three-dimensional): Head slope, nose slope, side slope, crest, riser Down-slope shape: Concave, convex, linear Across-slope shape: Convex, linear, concave Hydric soil rating: No Sudbury Percent of map unit: 2 percent Landscape: Valleys, uplands Landform: Kames, Eskers, Outwash deltas, Outwash plains, Kame terraces, Outwash terraces, Moraines Landform position (two-dimensional): Backslope, footslope Landform position (three-dimensional): Base slope, tread Down-slope shape: Concave, linear Across-slope shape: Linear, concave Hydric soil rating: No Custom Soil Resource Report 16
Page 187
References American Association of State Highway and Transportation Officials (AASHTO). 2004. Standard specifications for transportation materials and methods of sampling and testing. 24th edition. American Society for Testing and Materials (ASTM). 2005. Standard classification of soils for engineering purposes. ASTM Standard D2487-00. Cowardin, L.M., V. Carter, F.C. Golet, and E.T. LaRoe. 1979. Classification of wetlands and deep-water habitats of the United States. U.S. Fish and Wildlife Service FWS/OBS-79/31. Federal Register. July 13, 1994. Changes in hydric soils of the United States. Federal Register. September 18, 2002. Hydric soils of the United States. Hurt, G.W., and L.M. Vasilas, editors. Version 6.0, 2006. Field indicators of hydric soils in the United States. National Research Council. 1995. Wetlands: Characteristics and boundaries. Soil Survey Division Staff. 1993. Soil survey manual. Soil Conservation Service. U.S. Department of Agriculture Handbook 18. http://www.nrcs.usda.gov/wps/portal/ nrcs/detail/national/soils/?cid=nrcs142p2_054262 Soil Survey Staff. 1999. Soil taxonomy: A basic system of soil classification for making and interpreting soil surveys. 2nd edition. Natural Resources Conservation Service, U.S. Department of Agriculture Handbook 436. http:// www.nrcs.usda.gov/wps/portal/nrcs/detail/national/soils/?cid=nrcs142p2_053577 Soil Survey Staff. 2010. Keys to soil taxonomy. 11th edition. U.S. Department of Agriculture, Natural Resources Conservation Service. http:// www.nrcs.usda.gov/wps/portal/nrcs/detail/national/soils/?cid=nrcs142p2_053580 Tiner, R.W., Jr. 1985. Wetlands of Delaware. U.S. Fish and Wildlife Service and Delaware Department of Natural Resources and Environmental Control, Wetlands Section. United States Army Corps of Engineers, Environmental Laboratory. 1987. Corps of Engineers wetlands delineation manual. Waterways Experiment Station Technical Report Y-87-1. United States Department of Agriculture, Natural Resources Conservation Service. National forestry manual. http://www.nrcs.usda.gov/wps/portal/nrcs/detail/soils/ home/?cid=nrcs142p2_053374 United States Department of Agriculture, Natural Resources Conservation Service. National range and pasture handbook. http://www.nrcs.usda.gov/wps/portal/nrcs/ detail/national/landuse/rangepasture/?cid=stelprdb1043084 17
Page 188
United States Department of Agriculture, Natural Resources Conservation Service. National soil survey handbook, title 430-VI. http://www.nrcs.usda.gov/wps/portal/ nrcs/detail/soils/scientists/?cid=nrcs142p2_054242 United States Department of Agriculture, Natural Resources Conservation Service. 2006. Land resource regions and major land resource areas of the United States, the Caribbean, and the Pacific Basin. U.S. Department of Agriculture Handbook 296. http://www.nrcs.usda.gov/wps/portal/nrcs/detail/national/soils/? cid=nrcs142p2_053624 United States Department of Agriculture, Soil Conservation Service. 1961. Land capability classification. U.S. Department of Agriculture Handbook 210. http:// www.nrcs.usda.gov/Internet/FSE_DOCUMENTS/nrcs142p2_052290.pdf Custom Soil Resource Report 18
Page 189
Geotechnical Report Vessel Residential 37 Hartford Avenue Granby, Connecticut Submitted to: Vessel Technologies, Inc. 46 West 55 th Street New York, NY 10019 Submitted by: GEI Consultants, Inc. 455 Winding Brook Drive, Suite 201 Glastonbury, CT 06033 860-368-5300 February 16, 2023 Project No. 2204905 Thomas Rezzani, E.I.T. Geotechnical Professional Matthew Glunt, P.E. Senior Geotechnical Engineer Consulting Engineers and Scientists
Page 190
G E O T E C H N I C A L R E P O R T V E S S E L R E S I D E N T I A L G R A N B Y , C O N N E C T I C U T F E B R U A R Y 1 6 , 2 0 2 3 GEI Consultants, Inc. i Table of Contents 1. Introduction 1 1.1 Project Summary 1 1.2 Scope of Services 1 1.3 Authorization 1 2. Site and Project Description 2 2.1 Site Description and History 2 2.2 Proposed Construction 2 3. Exploration Procedures 3 3.1 Test Borings 3 3.2 Monitoring Well Installation 3 3.3 Laboratory Testing 3 4. Subsurface Conditions 4 4.1 Geologic Setting 4 4.2 Subsurface Conditions 4 4.3 Groundwater Conditions 4 5. Design Recommendations 5 5.1 Foundation Design 5 5.2 Settlement 5 5.3 Seismic Design 6 5.4 Lateral Earth Pressures 6 5.5 Pavement Design 7 5.6 Subsurface Drainage Design 8 6. Construction Considerations 10 6.1 Subgrade Preparation 10 6.1.1 General 10 6.1.2 Pavements 10 6.1.3 Foundations 11 6.2 Excavation and Dewatering 11 6.3 Freezing Conditions 11 6.4 Backfilling and Compaction 12 7. Closure 13 7.1 Follow-on Services 13 7.2 Limitations 13
Page 191
G E O T E C H N I C A L R E P O R T V E S S E L R E S I D E N T I A L G R A N B Y , C O N N E C T I C U T F E B R U A R Y 1 6 , 2 0 2 3 GEI Consultants, Inc. ii Figures 1 Boring Location Plan Appendices A Boring and Monitoring Well Logs B Laboratory Test Results C Recommended Material Specifications D Infiltration/Permeability Testing Results
Page 192
G E O T E C H N I C A L R E P O R T V E S S E L R E S I D E N T I A L G R A N B Y , C O N N E C T I C U T F E B R U A R Y 1 6 , 2 0 2 3 GEI Consultants, Inc. 1 1. Introduction 1.1 Project Summary The approximately 2.55-acre site slated for development is located at 37 Hartford Avenue in Granby, Connecticut. We understand that the project will consist of forty-eight (48) prefabricated residential units stacked evenly over four floors, with a footprint of 8,591 square feet. The appurtenant site features include a parking area, access drive, and storm water management. This report was prepared to address foundation and site preparation recommendations for the proposed construction. 1.2 Scope of Services Our scope of work included the following tasks: • Engaged a subcontractor to drill three (3) test borings on the property to depths of 22 feet each. • Observed soil samples recovered from the test borings and prepared test boring logs. • Installation of two (2) temporary monitoring wells to depths of 8 feet each and conducted downhole infiltration testing within each. • Engaged a testing laboratory to perform three (3) grain-size analyses on soil samples to verify visual classification and evaluate subsurface conditions regarding infiltration capacity. • Developed recommendations for site preparation, pavement sections, excavation, backfill, seismic design, lateral wall pressures, foundation design, infiltration rate, and construction considerations. • Prepared this Geotechnical Report. 1.3 Authorization Our work was performed in general accordance with our proposal dated December 15, 2022, and our Standard Professional Services agreement executed December 21, 2022.
Page 193
G E O T E C H N I C A L R E P O R T V E S S E L R E S I D E N T I A L G R A N B Y , C O N N E C T I C U T F E B R U A R Y 1 6 , 2 0 2 3 GEI Consultants, Inc. 2 2. Site and Project Description 2.1 Site Description and History The property slated for development is a semi-vacant 2.55-acre lot located at 37 Hartford Ave. in Granby, Connecticut. The site is bounded by Hartford Ave (Route 189) to the north, undeveloped land to the south, and commercial properties to the east and west. The site currently includes a partially finished walkout lower level with concrete walls and slab-on-grade. From a cursory review of aerial photographs, we understand this lot formerly housed a small residence within the approximate footprint of the current walls, which was demolished in or about 2006. The lower level currently on the site was constructed in or about 2010, with the remainder of the structure never completed. The site also includes soil stockpiles which, we assume, are remnant of the lower-level excavation. 2.2 Proposed Construction Our current understanding of the project is based on the information provided to GEI as shown on the Sketch Plan print dated 10/28/2022, as detailed below. We understand that the project involves construction of a four-story residential building consisting of stacked prefabricated units with a footprint of 8,591-sf. We also understand the structure will likely be founded on a series of grade beams supporting load-bearing walls and an elevated cold-formed metal panel floor. Site grading is expected to largely follow existing contours, with most areas of improvement requiring cuts and fills less than 5 feet. Preliminary plans provided to GEI show construction of 62 parking spaces to the south of the building. Stormwater management is expected to consist of a series of subsurface chambers installed below the southern portion of the parking area.
Page 194
G E O T E C H N I C A L R E P O R T V E S S E L R E S I D E N T I A L G R A N B Y , C O N N E C T I C U T F E B R U A R Y 1 6 , 2 0 2 3 GEI Consultants, Inc. 3 3. Exploration Procedures 3.1 Test Borings The boring locations were laid out on the site from the provided conceptual plan using handheld GPS. Borings were located within the proposed building footprint. Approximate boring locations relative to the property boundary and conceptual site plan are shown on Figure 1. Three (3) soil test borings (B-1 through B-3) were performed at the site on January 12, 2023, by Seaboard Drilling Inc., under subcontract to GEI. The appropriate one-call utility location service (Call Before You Dig) was contacted prior to our arrival. All borings were advanced to depths of 22 feet using hollow-stem augering techniques and a track-mounted drilling rig. Boring logs are attached in Appendix A. Standard Penetration Testing (SPT) and split-spoon sampling were performed continuously through the upper 8 feet of the borings and at 5-foot intervals thereafter using a 140-pound automatic hammer. Representative samples of the soils obtained by the sampler were classified by the on-site GEI engineer. The samples were placed in appropriately identified sealed glass jars and transported to our office for laboratory assignment. Borings were backfilled with drill cuttings upon completion. 3.2 Monitoring Well Installation Two (2) temporary PVC wells (MW-1 and MW-2) were installed on the southern portion of the site. The well installation logs are attached in Appendix A for reference. Falling-head measurements were conducted within the wells until stabilized readings were noted, the results of which are attached in Appendix D. 3.3 Laboratory Testing Laboratory testing was conducted on representative soil samples to confirm field identification of the soils and establish engineering characteristics for design. Tests performed by GeoTesting Express, under subcontract to GEI, included the following: • Three (3) grain-size analysis with standard sieve set (ASTM D6913) • Three (3) moisture content analyses (ASTM D2216) Results of the laboratory testing program are included in Appendix B.
Page 195
G E O T E C H N I C A L R E P O R T V E S S E L R E S I D E N T I A L G R A N B Y , C O N N E C T I C U T F E B R U A R Y 1 6 , 2 0 2 3 GEI Consultants, Inc. 4 4. Subsurface Conditions 4.1 Geologic Setting The Surficial Geology Map of Connecticut (Stone et al., 1992) indicates that this area of Granby lies on a broad plain of glacial outwash sands over fine-grained deposits. 4.2 Subsurface Conditions The generalized subsurface conditions at the site are described below, in order of increasing depth. The subsurface conditions between boring locations may differ. The nature and extent of variations between the sampling points will not become evident until construction. Topsoil – Topsoil thickness on the site was generally measured as 8 to 13 inches, with a thicker zone of approximately 30 inches noted at boring B-3. Native Sand – Thick, stratified deposits of glacial outwash sand were encountered to termination depth of the borings. Below the topsoil, these sands were generally sampled as fine to coarse-grained reddish-brown sand with up to 15 percent non-plastic fines. Gravel content, up to 20 percent, was more apparent in the near-surface sampling. Standard Penetration Test (SPT) N-values typically ranged between 9 to 14 blows/foot, indicating loose to medium-dense conditions. 4.3 Groundwater Conditions Groundwater was not encountered in the test borings or wells to a maximum investigation depth of 22 feet. Groundwater levels are subject to seasonal and weather-related variations. Groundwater measurements made at different times and different locations may be significantly different than the measurements taken as part of this investigation.
Page 196
G E O T E C H N I C A L R E P O R T V E S S E L R E S I D E N T I A L G R A N B Y , C O N N E C T I C U T F E B R U A R Y 1 6 , 2 0 2 3 GEI Consultants, Inc. 5 5. Design Recommendations 5.1 Foundation Design The proposed structure may be supported on shallow foundations bearing on a subgrade consisting of native sands or compacted Structural Fill. If existing remnant fills are encountered within the building pad during foundation installation, these soils must be removed and replaced with compacted Structural Fill or, alternatively, crushed stone. We recommend that all footing subgrades be evaluated by a GEI representative prior to concrete placement. The maximum allowable bearing pressures for the design of footings are: Table 1: Allowable Bearing Pressure Bearing Stratum Net Allowable Bearing Pressure Crushed Stone over Native Sands or Structural Fill 3,000 lb/ft 2 Minimum individual column footing and wall footing widths should be at least 36 and 18 inches, respectively. Exterior footings should bear at least 3½ feet below the adjacent exterior grade for frost protection. Interior footings should be founded at least 18 inches below the bottom of the floor slab. The tops of all footings should be at least 6 inches below the bottom of the overlying floor slab. As shown on conceptual plans, we recommend that the grade beams bear on a minimum 6- inch working pad of crushed stone wrapped on the sides by a geotextile fabric, placed over a soil subgrade prepared in accordance with Section 6.1. This will serve to protect subgrades and improve expediency of foundation construction. Crushed Stone meeting the specifications in Appendix C may be considered non-frost susceptible. 5.2 Settlement We understand structure loads on the 18-inch-wide grade beams will be on the order of 3.5 kips/ft. Assuming the design and construction recommendations herein are followed, we estimate total settlement of the building will be less than 1 inch, and differential settlement will be less than ½ inch. We expect nearly all expected settlements will occur during construction or soon after.
Page 197
G E O T E C H N I C A L R E P O R T V E S S E L R E S I D E N T I A L G R A N B Y , C O N N E C T I C U T F E B R U A R Y 1 6 , 2 0 2 3 GEI Consultants, Inc. 6 5.3 Seismic Design The 2018 edition of the Connecticut Building Code document mirrors the 2015 International Building Code, with exception of the revisions and supplemental information provided by state building officials. Based on the criteria of Building Code Section 1613.3.2 and the SPT N-values measured on site, we recommend the use of Site Class D for seismic design. The Site Class was used in conjunction with the seismic hazard (SS, S 1) for this location to determine spectral design values, as follows: Table 2: Seismic Design Values 2018 Connecticut Building Code SS 0.171 g S1 0.054 g SDS 0.183 g SD1 0.087 g PGA M 0.144 g Seismic Design Category (Risk Category I, II, or III) B We calculated the spectral response parameters for the site using general procedures outlined in Building Code Section 1613.3. Peak ground acceleration (PGA M) is adjusted for Site Class effects, per ASCE 7-10 Section 11.8.3. The soils below the foundation level at this site are not considered susceptible to liquefaction. 5.4 Lateral Earth Pressures All earth retaining structures used on the project should be designed using the earth pressures shown in Table 3. Note that no factor of safety has been applied to these values. Below- grade walls that are restrained from movement should be designed for at-rest earth pressures. Retaining walls free to rotate at the top should be designed for active earth pressures. In addition to the lateral loads exerted by the soil against the walls, allowance should be included for lateral stresses imposed by any temporary or long-term surcharge loads, such as cars or trucks adjacent to the walls or adjacent footing loads.
Page 198
G E O T E C H N I C A L R E P O R T V E S S E L R E S I D E N T I A L G R A N B Y , C O N N E C T I C U T F E B R U A R Y 1 6 , 2 0 2 3 GEI Consultants, Inc. 7 Table 3: Wall Design Parameters Material Total Unit Weight (γ, pcf) Friction Angle (Φ) Cohesion (c) At-Rest Earth Pressure Coeff (K o) Active Earth Pressure Coeff, (K a) Passive Earth Pressure Coeff, (K p) Native Sands 120 34º 0 0.44 0.28 3.00 Structural Fill 125 34º 0 0.44 0.28 3.00 We recommend limiting the passive pressure coefficient to 3.00 as shown above, due to the relatively high movement required to fully engage passive resistance. The minimum factors of safety for sliding and overturning under static loads should be 1.5 and 2.0, respectively. An allowable coefficient of friction of 0.50 between the grade beam and crushed stone over granular bearing soil may be assumed. The recommended wall design parameters do not consider the development of hydrostatic pressure behind the walls. As such, positive wall drainage must be provided for all earth retaining structures. These drainage systems can be constructed of open-graded washed stone isolated from the soil backfill with a geosynthetic filter fabric and drained by perforated pipe, or several wall drainage products made specifically for this application. Where backfill soils are not drained using an appropriately designed drainage system, the lateral soil pressure on proposed retaining walls must consider hydrostatic forces and submerged soil unit weight. The earth pressures given in Table 3 assume placement and compaction of the backfill in accordance with recommendations elsewhere in this report. Compact backfill directly behind walls with light, hand-operated compactors. Heavy compactors and grading equipment should not be allowed to operate within 10 feet of the walls during backfilling to avoid developing excessive temporary or long-term lateral soil pressures. 5.5 Pavement Design Soils similar to the native sands at the site, as well as any new structural fill, are generally considered to be well-suited to support of pavements, assuming the subgrade is prepared as recommended in this report. The south tenant parking area may be designed with light-duty pavements, while those areas expected to receive repeated truck traffic, such as dumpster pads, should be designed as a rigid pavement section. We recommend the following pavement sections for these areas:
Page 199
G E O T E C H N I C A L R E P O R T V E S S E L R E S I D E N T I A L G R A N B Y , C O N N E C T I C U T F E B R U A R Y 1 6 , 2 0 2 3 GEI Consultants, Inc. 8 Light-Duty Parking Area 3.0 inches bituminous concrete • 1.5 inches wearing course (CTDOT M.04.03 Class 2 or Superpave HMA S0.5) • 1.5 inches binder course (CTDOT M.04.03 Class 1 or Superpave HMA S1.0) 8.0 inches of processed aggregate base (CTDOT Form 818 M05.01) Heavy-Duty Rigid Concrete Section 6.0 inches of 4,000-psi jointed concrete (CTDOT M.03.01 Portland Cement) 8.0 inches of processed aggregate base (CTDOT Form 818 M05.01) Recommended pavement sections are based on AASHTO Guide for Design of Pavement Structures (1993) and ACI 330R. Pavement materials should conform with and be placed in accordance with the Connecticut Department of Transportation (CTDOT) Standard Specifications for Road, Bridges, and Incidental Construction (Form 818), 2020. CTDOT- compliant reclaimed miscellaneous aggregate with a loss on abrasion of less than 50 percent may be used as base course for pavements. Rigid pavement sections should be designed and constructed in accordance with appropriate American Concrete Institute (ACI) recommendations and with the applicable specifications of the CTDOT Standard Specifications. An adequate number of smooth steel dowels should be provided at all control and construction joints. All dowels should be coated and lubricated and affixed with metal or plastic caps. The size and spacing of dowels should conform to recommendations in ACI 330R. All joints should also be sealed with a flexible fuel resistant sealer to minimize surface water infiltration into the prepared base. According to AASHTO design guidelines, the recommended pavement sections shown above are suitable for a 20-year design life. However, pavement maintenance such as sealing of cracks and localized patching due to normal weathering should be expected within the first 5 to 10 years of life. 5.6 Subsurface Drainage Design We understand below-ground infiltration chambers will likely be constructed on the property for stormwater management purposes. Based on the results of the investigation, these systems will likely be founded in highly permeable sand deposits. Based on the investigation data, groundwater appears to be in excess of 20 feet below present grade. Hydraulic conductivities at the monitoring well locations (MW-1 and MW-2) were estimated using downhole falling-head field measurements and published equations for borehole permeability. The calculations presented in Appendix D are consistent with highly permeable soil. Though the field-measured data indicate infiltration rates of over 100
Page 200
G E O T E C H N I C A L R E P O R T V E S S E L R E S I D E N T I A L G R A N B Y , C O N N E C T I C U T F E B R U A R Y 1 6 , 2 0 2 3 GEI Consultants, Inc. 9 inches/hour, we recommend assuming an infiltration rate of 40.0 inches/hour for stormwater system design. Per CT DEEP regulations, a factor of safety of 2.0 must be applied to this value for design.
Page 201
G E O T E C H N I C A L R E P O R T V E S S E L R E S I D E N T I A L G R A N B Y , C O N N E C T I C U T F E B R U A R Y 1 6 , 2 0 2 3 GEI Consultants, Inc. 10 6. Construction Considerations 6.1 Subgrade Preparation 6.1.1 General To prepare the site for grading operations, topsoil, organic matter, and other deleterious material should be stripped from the building and site improvement areas. Soft, wet, loose, or otherwise un-suitable soils should be removed and replaced, or potentially re-compacted in-place. Site preparations should also include the removal of all soil stockpiles and other above- ground features remnant of the partially-constructed building on site. Subject to further evaluation, these soils can be potentially beneficially re-used on the project. 6.1.2 Site Demolition Any foundation remnants within the proposed building pad should be removed and the entire footprint backfilled to grade with Structural Fill. Below-grade elements such as foundation walls may be left in place within pavement and landscaped areas, cut to at least 2 feet below the bottom of subgrade elevation to reduce the potential for a hard spot forming. Existing utilities to remain in use should be rerouted around the proposed building footprint. If not removed, any pipes over 3 inches in diameter should be filled with flowable fill or grout. Otherwise, these pipes may serve as conduits for subsurface erosion resulting in formation of voids below foundations or floor slabs. Where existing utilities are left in place and plugged in the building footprint, it may be necessary to undercut poorly compacted backfill to provide adequate support for footings or slabs. 6.1.3 Pavements Following the required stripping, excavation to rough grade, and before placing new fill to achieve design grades, the resulting subgrade should be firm, stable, and unyielding. Stabilization, where required, may consist of removing unsuitable material and replacement with compacted structural fill, or where unsuitable soils are relatively thin, drying and compacting in place. Soil subgrades should be proof-rolled with at least four (4) passes of a minimum 10-ton vibratory roller in open areas, or a 1-ton vibratory roller or large plate compactor, such as Wacker DPU4545 or equivalent, in trenches. Proof-rolling in close proximity to groundwater, if encountered, may need to be accomplished without vibratory action to reduce the potential for disturbance to the subgrade.
Page 202
G E O T E C H N I C A L R E P O R T V E S S E L R E S I D E N T I A L G R A N B Y , C O N N E C T I C U T F E B R U A R Y 1 6 , 2 0 2 3 GEI Consultants, Inc. 11 6.1.4 Foundations Footings should bear on a subgrade consisting of native sands or compacted Structural Fill. Bearing surfaces should be free of standing water, frost, and loose soil before placement of reinforcing steel and concrete. Historic fills associated with demolition of the former residence on the site or construction of the current basement may be encountered within the building pad. If encountered, historic fills must be removed within foundation excavations and replaced with Structural Fill or, alternatively, crushed stone. We recommend that a GEI representative observe the final preparation of all subgrades prior to footing construction. Subgrade soils that require undercutting should be replaced with either compacted structural fill or crushed stone. As shown on conceptual plans, we recommend that the grade beams bear on a minimum 6- inch working pad of crushed stone wrapped on the sides by a geotextile fabric, placed over an approved soil subgrade. This will serve to protect subgrades and improve expediency of foundation construction. Crushed Stone meeting the specifications in Appendix C may be considered non-frost susceptible. 6.2 Excavation and Dewatering Excavations can be accomplished with conventional earthmoving equipment. Excavations should be sloped or shored in accordance with the local, state, and federal regulations, including Occupational Safety and Health Agency (OSHA 29 CFR Part 1926) excavation trench safety standards. Groundwater was not encountered during this investigation and is not likely to impact grading operations. That said, site relief is very low, and maintaining proper site drainage during initial grading may become very difficult unless measures to control surface water are put in place before grading starts and maintained throughout. 6.3 Freezing Conditions The native sands that will form the subgrades for grade slabs, footings, and pavements can be expected to have a low to moderate susceptibility to frost. Accordingly, we do not believe that special measures beyond the design and construction recommendations provided herein are required to guard against potential frost heave of subgrade soils. That said, we recommend certain precautions for cold-weather earthwork. All subgrades should be free of frost before placement of concrete. Frost-susceptible soils that have frozen
Page 203
G E O T E C H N I C A L R E P O R T V E S S E L R E S I D E N T I A L G R A N B Y , C O N N E C T I C U T F E B R U A R Y 1 6 , 2 0 2 3 GEI Consultants, Inc. 12 should be removed and replaced with compacted Structural Fill. The footing and the soil adjacent to the footing should be insulated until they are backfilled. Soil placed as fill should be free of frost, as should the ground on which it is placed. If slabs-on-grade or footings are built and left exposed during the winter, precautions should be taken to prevent freezing of the underlying soil. 6.4 Backfilling and Compaction Recommended specifications for gradation and compaction of backfill soils are provided in the attached recommended Material Specifications (Appendix C). Native sands excavated as part of earthwork activities can likely be re-used on site as Structural Fill or Ordinary Fill, provided they do not contain oversize, organic, or otherwise deleterious material and can meet the appropriate compaction requirements. Fill imported from off site should meet the attached gradation requirements. Fill placed within the building limits, within a 3-foot-wide zone outside foundation walls, under pavements, and behind retaining walls should meet the compaction requirements for Structural Fill. Backfill placed in non-structural areas should meet the compaction requirements for Ordinary Fill. Proposed borrow materials that fall slightly outside of these specifications may also be suitable for use, subject to review and approval by GEI.
Page 204
G E O T E C H N I C A L R E P O R T
V E S S E L R E S I D E N T I A L
G R A N B Y , C O N N E C T I C U T
F E B R U A R Y 1 6 , 2 0 2 3
GEI Consultants, Inc. 13
7. Closure
7.1 Follow-on Services
We recommend that GEI be kept on the project through the final design and construction
phases for the following services:
Review geotechnical-related contractor submittals and assist in developing responses
to questions from the contractor (i.e. RFI’s).
Provide periodic site visits during construction to view subgrades and consult on
geotechnical-related issues that occur.
7.2 Limitations
This report was prepared for the use of the project team, exclusively. Our recommendations
are based on the project information provided to us at the time of this report and may require
modification if there are any changes in the nature, design, or location of the proposed
building. We cannot accept responsibility for designs based on our recommendations unless
we are engaged to review the final plans and specifications to determine whether any changes
in the project affect the validity of our recommendations, and whether our recommendations
have been properly implemented in the design.
Our professional services for this project have been performed in accordance with generally
accepted engineering practices. No warranty, expressed or implied, is made.
Page 205
G E O T E C H N I C A L R E P O R T V E S S E L R E S I D E N T I A L G R A N B Y , C O N N E C T I C U T F E B R U A R Y 1 6 , 2 0 2 3 GEI Consultants, Inc. Figures
Page 206
FIGURE NO. GEI PROJECT NO: 2204905 BORING LOCATION PLAN 37 HARTFORD AVE GRANBY, CT 1 LEGEND APPROXIMATE BORING/MON. WELL LOCATION B-3 B-1 B-2 SOURCE: CONCEPT PLAN (CSP-A), H+H ENGINEERING ASSOC., 10/28/2022 MW-1 MW-2
Page 207
G E O T E C H N I C A L R E P O R T V E S S E L R E S I D E N T I A L G R A N B Y , C O N N E C T I C U T F E B R U A R Y 1 6 , 2 0 2 3 GEI Consultants, Inc. Appendix A Boring and Monitoring Well Logs
Page 208
NATIVE SAND
0
to
2
2
to
4
4
to
6
6
to
8
10
to
12
15
to
17
20
to
22
S1: WIDELY GRADED SAND WITH SILT (SW-SM); ~80% F-C
sand, ~10% NP fines, ~10% F-C gravel, brown, moist. TOPSOIL
S2: WIDELY GRADED SAND WITH GRAVEL (SW); 75.2% F-C
sand, 20.2% F-C gravel, 4.6% NP fines, brown, moist.
S3: Similar to S2.
S4: Similar to S2.
S5: WIDELY GRADED SAND WITH SILT (SW-SM); ~90% F-C
sand, ~10% NP fines, light-brown, moist.
S6: NARROWLY GRADED SAND WITH SILT (SP-SM); ~90%
F-C sand, ~10% NP fines, reddish-brown, moist.
S7: Similar to S6.
Planned depth.
Backfilled with drill cuttings.
S1
S2
S3
S4
S5
S6
S7
24/13
24/9
24/14
24/14
24/8
24/14
24/15
2-2-4-4
4-5-5-5
2-4-5-6
5-7-5-6
4-5-5-7
3-6-10-
12
8-12-13-
18
Sv = Pocket Torvane Shear Strength
PI = Plasticity Index
NA, NM = Not Applicable, Not Measured
Blows per 6 in.: 140-lb hammer falling
30 inches to drive a 2-inch-O.D.
split spoon sampler.
CORE BARREL I.D./O.D. NA / NADRILL ROD O.D.: NM
CASING I.D./O.D.: NA / NA
WATER LEVEL DEPTHS (ft): Free groundwater not encountered.
DRILLER NAME: J. Nitsch
C = Core Sample
S = Split Spoon Sample
U = Undisturbed Sample
SC = Sonic Core
CORE BARREL TYPE:
WOR = Weight of Rods
WOH = Weight of Hammer
DRILLING METHOD: Hollow Stem Auger
LL = Liquid Limit
PID = Photoionization Detector
Pen. = Penetration Length
Rec. = Recovery Length
BORING INFORMATION
AUGER I.D./O.D.: 3.75 inch / NA
Qp = Pocket Penetrometer Strength
I.D./O.D. = Inside Diameter/Outside Diameter
PAGE 1 of 1
B-1
DP = Direct Push Sample
HSA = Hollow-Stem Auger
TOTAL DEPTH (ft): 22.0
RQD = Rock Quality Designation
= Length of Sound Cores>4 in / Pen.,%
HAMMER TYPE: Safety Hammer - semi-automatic
ABBREVIATIONS:
DRILLING INFORMATION
LOGGED BY: T. Yurman RIG TYPE: Diedrich D-50 ATV
Layer Name
Depth
(ft)
Soil and Rock Description
Sample Information
Sample
No.
Pen./
Rec.
(in)
Blows
per 6 in.
or RQD
Depth
(ft)
5
10
15
20
Elev.
(ft)
200
190
Drilling Remarks/
Field Test Data
NOTES:
PROJECT NAME: Vessel-Granby
GEI PROJECT NUMBER: 2204905
CITY/STATE: Granby, Connecticut
_GEI WOBURN STD 1-LOCATION-LAYER NAME 2204905 - VESSEL GRANBY.GPJ GEI DATA TEMPLATE 2013.GDT 2/14/23
VERTICAL DATUM:
DATE START/END: 1/12/2023 - 1/12/2023
DRILLING COMPANY: Seaboard Drilling, Inc.
GROUND SURFACE EL. (ft): 205
LOCATION: See plan. BORINGPage 209
NATIVE SAND
0
to
2
2
to
4
4
to
6
6
to
8
10
to
12
15
to
17
20
to
22
S1: WIDELY GRADED SAND WITH SILT (SW-SM); ~85% F-C
sand, ~10% NP fines, ~5% F-C gravel, organic fibers brown,
moist. TOPSOIL
S2: WIDELY GRADED SAND WITH GRAVEL (SW); 81.7% F-C
sand, 14.5% F-C gravel, 3.8% NP fines, reddish brown, moist.
S3: Similar to S2.
S4: NARROWLY GRADED SAND WITH SILT (SP-SM); ~80%
M-C sand, ~10% NP fines, ~10% F-C gravel, brown, moist.
S5: Similar to S4.
S6: SILTY SAND (SM); ~85% F-M sand, ~15% NP fines,
light-brown, moist.
S7: SILTY SAND (SM); ~85% F-sand, ~15% NP fines,
light-brown, moist.
Planned depth.
Backfilled with drill cuttings.
S1
S2
S3
S4
S5
S6
S7
24/8
24/14
24/17
24/16
24/14
24/18
24/15
2-3-3-3
6-7-6-7
3-3-3-3
3-5-6-8
5-5-6-6
5-6-8-8
4-5-8-9
Sv = Pocket Torvane Shear Strength
PI = Plasticity Index
NA, NM = Not Applicable, Not Measured
Blows per 6 in.: 140-lb hammer falling
30 inches to drive a 2-inch-O.D.
split spoon sampler.
CORE BARREL I.D./O.D. NA / NADRILL ROD O.D.: NM
CASING I.D./O.D.: NA / NA
WATER LEVEL DEPTHS (ft): Free groundwater not encountered.
DRILLER NAME: J. Nitsch
C = Core Sample
S = Split Spoon Sample
U = Undisturbed Sample
SC = Sonic Core
CORE BARREL TYPE:
WOR = Weight of Rods
WOH = Weight of Hammer
DRILLING METHOD: Hollow Stem Auger
LL = Liquid Limit
PID = Photoionization Detector
Pen. = Penetration Length
Rec. = Recovery Length
BORING INFORMATION
AUGER I.D./O.D.: 3.75 inch / NA
Qp = Pocket Penetrometer Strength
I.D./O.D. = Inside Diameter/Outside Diameter
PAGE 1 of 1
B-2
DP = Direct Push Sample
HSA = Hollow-Stem Auger
TOTAL DEPTH (ft): 22.0
RQD = Rock Quality Designation
= Length of Sound Cores>4 in / Pen.,%
HAMMER TYPE: Safety Hammer - semi-automatic
ABBREVIATIONS:
DRILLING INFORMATION
LOGGED BY: T. Yurman RIG TYPE: Diedrich D-50 ATV
Layer Name
Depth
(ft)
Soil and Rock Description
Sample Information
Sample
No.
Pen./
Rec.
(in)
Blows
per 6 in.
or RQD
Depth
(ft)
5
10
15
20
Elev.
(ft)
200
190
Drilling Remarks/
Field Test Data
NOTES:
PROJECT NAME: Vessel-Granby
GEI PROJECT NUMBER: 2204905
CITY/STATE: Granby, Connecticut
_GEI WOBURN STD 1-LOCATION-LAYER NAME 2204905 - VESSEL GRANBY.GPJ GEI DATA TEMPLATE 2013.GDT 2/14/23
VERTICAL DATUM:
DATE START/END: 1/12/2023 - 1/12/2023
DRILLING COMPANY: Seaboard Drilling, Inc.
GROUND SURFACE EL. (ft): 208
LOCATION: See plan. BORINGPage 210
NATIVE SAND
0
to
2
2
to
4
4
to
6
6
to
8
10
to
12
15
to
17
20
to
22
S1: WIDELY GRADED SAND WITH SILT (SW-SM); ~80% F-C
sand, ~10% NP fines, ~10% F-C gravel, some organic fibers,
reddish-brown, damp to moist. TOPSOIL
S2A (0-6"): Similar to S1.
S2B (6-13"): SILTY SAND (SM); ~75% F-sand, ~25% NP-LP
fines, damp to moist, reddish-brown.
S3: SILTY SAND (SM); ~85% F-M sand, ~15% NP fines, moist,
reddish-brown, some LP fines at top of recovery.
S4: SILTY SAND (SM); 97.6% F-C sand, 2.4% NP fines,
light-brown, moist.
S5: Similar to S4.
S6: Similar to S4.
S7: Similar to S4.
Planned depth.
Backfilled with drill cuttings.
S1
S2
S3
S4
S5
S6
S6
24/12
24/13
24/18
24/18
24/17
24/23
24/19
1-3-4-5
6-9-6-5
3-5-5-5
4-6-8-8
4-6-7-9
4-7-6-7
5-6-8-9
Sv = Pocket Torvane Shear Strength
PI = Plasticity Index
NA, NM = Not Applicable, Not Measured
Blows per 6 in.: 140-lb hammer falling
30 inches to drive a 2-inch-O.D.
split spoon sampler.
CORE BARREL I.D./O.D. NA / NADRILL ROD O.D.: NM
CASING I.D./O.D.: NA / NA
WATER LEVEL DEPTHS (ft): Free groundwater not encountered.
DRILLER NAME: J. Nitsch
C = Core Sample
S = Split Spoon Sample
U = Undisturbed Sample
SC = Sonic Core
CORE BARREL TYPE:
WOR = Weight of Rods
WOH = Weight of Hammer
DRILLING METHOD: Hollow Stem Auger
LL = Liquid Limit
PID = Photoionization Detector
Pen. = Penetration Length
Rec. = Recovery Length
BORING INFORMATION
AUGER I.D./O.D.: 3.75 inch / NA
Qp = Pocket Penetrometer Strength
I.D./O.D. = Inside Diameter/Outside Diameter
PAGE 1 of 1
B-3
DP = Direct Push Sample
HSA = Hollow-Stem Auger
TOTAL DEPTH (ft): 22.0
RQD = Rock Quality Designation
= Length of Sound Cores>4 in / Pen.,%
HAMMER TYPE: Safety Hammer - semi-automatic
ABBREVIATIONS:
DRILLING INFORMATION
LOGGED BY: T. Yurman RIG TYPE: Diedrich D-50 ATV
Layer Name
Depth
(ft)
Soil and Rock Description
Sample Information
Sample
No.
Pen./
Rec.
(in)
Blows
per 6 in.
or RQD
Depth
(ft)
5
10
15
20
Elev.
(ft)
190
180
Drilling Remarks/
Field Test Data
NOTES:
PROJECT NAME: Vessel-Granby
GEI PROJECT NUMBER: 2204905
CITY/STATE: Granby, Connecticut
_GEI WOBURN STD 1-LOCATION-LAYER NAME 2204905 - VESSEL GRANBY.GPJ GEI DATA TEMPLATE 2013.GDT 2/14/23
VERTICAL DATUM:
DATE START/END: 1/12/2023 - 1/12/2023
DRILLING COMPANY: Seaboard Drilling, Inc.
GROUND SURFACE EL. (ft): 198
LOCATION: See plan. BORINGPage 211
Project GEI Proj. No. City / Town Location Client Contractor Driller Install Date Survey Datum: Length of Riser Pipe above Ground Ground Elevation: Type of Seal around Surface Casing Type of Surface Casing Surface Casing ID ID and OD of Riser Pipe Type of Riser Pipe Type of Backfill around Riser Pipe Diameter of Borehole Depth Top of Seal Type of Seal Depth Bottom of Seal Depth Top of Screened Section Type of Screen Description of Screen Openings ID and OD of Screened Section Type of Filter Material Depth Bottom of Screened Section Depth Bottom of Silt Trap Depth Bottom of Filter Material Depth Top of Seal Type of Seal Depth Bottom of Seal Type of Backfill below Filter Material Bottom of Borehole Notes: N/A No survey information available at time of well installation. Elevations should be considered approximate. N/A N/A N/A 8.0 ft BGS Time Distance to GW below ground surface 8.0 ft BGS N/A N/A N/A 1/12/2023 - >22.0 ft #2 Sand No Seal Date N/A 3.0 ft BGS Sch. 40 PVC 0.010 in. slots 2-inch ID Cuttings 3.75 in. N/A N/A No Casing PVC 2-inch ID 2.0 ft 197 N/A Seaboard Drilling J. Nitsch GEI Rep. T. Yurman 1/12/2023 Monitoring Well Installation Log MW-1 Vessel Residential Granby 2204905 37 Hartford Ave, Granby Proposed Parking Area/ South SideVessel Technologies
Page 212
Project GEI Proj. No. City / Town Location Client Contractor Driller Install Date Survey Datum: Length of Riser Pipe above Ground Ground Elevation: Type of Seal around Surface Casing Type of Surface Casing Surface Casing ID ID and OD of Riser Pipe Type of Riser Pipe Type of Backfill around Riser Pipe Diameter of Borehole Depth Top of Seal Type of Seal Depth Bottom of Seal Depth Top of Screened Section Type of Screen Description of Screen Openings ID and OD of Screened Section Type of Filter Material Depth Bottom of Screened Section Depth Bottom of Silt Trap Depth Bottom of Filter Material Depth Top of Seal Type of Seal Depth Bottom of Seal Type of Backfill below Filter Material Bottom of Borehole Notes: No survey information available at time of well installation. Elevations should be considered approximate. N/A N/A N/A 8.0 ft BGS Date Time Distance to GW below ground surface 8.0 ft BGS N/A N/A N/A 1/12/2023 - >22.0 ft #2 Sand 3.0 ft BGS Sch. 40 PVC 0.010 in. slots 2-inch ID 3.75 in. N/A N/A N/A 2-inch ID PVC Cuttings N/A No Casing N/A 2.0 ft 200 No Seal Seaboard Drilling J. Nitsch GEI Rep. T. Yurman 1/12/2023 Monitoring Well Installation Log MW-2 Vessel Residential Granby 2204905 37 Hartford Ave, Granby Proposed Parking Area/ South SideVessel Technologies
Page 213
G E O T E C H N I C A L R E P O R T V E S S E L R E S I D E N T I A L G R A N B Y , C O N N E C T I C U T F E B R U A R Y 1 6 , 2 0 2 3 GEI Consultants, Inc. Appendix B Laboratory Test Results
Page 214
Client: GEI Consultants, Inc. Project: Vessel Granby Location: Granby, CT Project No: GTX-316664 Boring ID: --- Sample ID: --- Depth : --- Sample Type: --- Test Date: 01/26/23 Test Id: 703269 Tested By: ckg Checked By: ank Moisture Content of Soil and Rock - ASTM D2216 printed 1/26/2023 3:35:13 PM Boring ID Sample ID Depth Description Moisture Content,% B-1 B-2 B-3 S2 S2 S4 2-4' 2-4' 6-8' Moist, reddish brown silty sand Moist, reddish brown silty sand Moist, brown silty sand 6.8 4.6 5.9 Notes: Temperature of Drying : 110º Celsius
Page 215
Client: GEI Consultants, Inc. Project: Vessel Granby Location: Granby, CT Project No: GTX-316664 Boring ID: B-1 Sample ID: S2 Depth : 2-4' Sample Type: jar Test Date: 01/26/23 Test Id: 703264 Tested By: ckg Checked By: ank Test Comment: --- Visual Description: Moist, reddish brown sand with gravel Sample Comment: --- Particle Size Analysis - ASTM D6913 printed 1/27/2023 11:18:09 AM 0 10 20 30 40 50 60 70 80 90 100 0.0010.010.11101001000 Percent Finer Grain Size (mm) 1 in 0.75 in 0.5 in 0.375 in #4 #10 #20 #40 #60 #100 #140 #200 % Co b b le --- % Gravel 20.2 % Sand 75.2 % Silt & Clay Size 4.6 Sieve Name Sieve Size, mm Percent Finer Spec. Percent Complies 1 in 0.75 in 0.5 in 0.375 in #4 #10 #20 #40 #60 #100 #140 #200 25.00 19.00 12.50 9.50 4.75 2.00 0.85 0.42 0.25 0.15 0.11 0.075 100 87 82 82 80 77 62 30 12 7 5 4.6 Coefficients D =16.2318 mm85 D =0.8086 mm60 D =0.6537 mm50 D =0.4273 mm30 D =0.2745 mm15 D =0.2066 mm10 C =3.914u C =1.093c Classification ASTM Poorly graded SAND with Gravel (SP) AASHTO Stone Fragments, Gravel and Sand (A-1-b (1)) Sample/Test Description Sand/Gravel Particle Shape : ANGULAR Sand/Gravel Hardness : HARD
Page 216
Client: GEI Consultants, Inc. Project: Vessel Granby Location: Granby, CT Project No: GTX-316664 Boring ID: B-2 Sample ID: S2 Depth : 2-4' Sample Type: jar Test Date: 01/26/23 Test Id: 703265 Tested By: ckg Checked By: ank Test Comment: --- Visual Description: Moist, reddish brown sand Sample Comment: --- Particle Size Analysis - ASTM D6913 printed 1/27/2023 11:18:10 AM 0 10 20 30 40 50 60 70 80 90 100 0.0010.010.11101001000 Percent Finer Grain Size (mm) 0.75 in 0.5 in 0.375 in #4 #10 #20 #40 #60 #100 #140 #200 % Co b b le --- % Gravel 14.5 % Sand 81.7 % Silt & Clay Size 3.8 Sieve Name Sieve Size, mm Percent Finer Spec. Percent Complies 0.75 in 0.5 in 0.375 in #4 #10 #20 #40 #60 #100 #140 #200 19.00 12.50 9.50 4.75 2.00 0.85 0.42 0.25 0.15 0.11 0.075 100 92 91 85 79 61 26 10 6 4 3.8 Coefficients D =4.4546 mm85 D =0.8259 mm60 D =0.6777 mm50 D =0.4563 mm30 D =0.2952 mm15 D =0.2516 mm10 C =3.283u C =1.002c Classification ASTM Poorly graded SAND (SP) AASHTO Stone Fragments, Gravel and Sand (A-1-b (1)) Sample/Test Description Sand/Gravel Particle Shape : ANGULAR Sand/Gravel Hardness : HARD
Page 217
Client: GEI Consultants, Inc. Project: Vessel Granby Location: Granby, CT Project No: GTX-316664 Boring ID: B-3 Sample ID: S4 Depth : 6-8' Sample Type: jar Test Date: 01/26/23 Test Id: 703266 Tested By: ckg Checked By: ank Test Comment: --- Visual Description: Moist, brown sand Sample Comment: --- Particle Size Analysis - ASTM D6913 printed 1/27/2023 11:18:11 AM 0 10 20 30 40 50 60 70 80 90 100 0.0010.010.11101001000 Percent Finer Grain Size (mm) #4 #10 #20 #40 #60 #100 #140 #200 % Co b b le --- % Gravel 0.0 % Sand 97.6 % Silt & Clay Size 2.4 Sieve Name Sieve Size, mm Percent Finer Spec. Percent Complies #4 #10 #20 #40 #60 #100 #140 #200 4.75 2.00 0.85 0.42 0.25 0.15 0.11 0.075 100 100 100 95 48 11 5 2.4 Coefficients D =0.3814 mm85 D =0.2871 mm60 D =0.2563 mm50 D =0.1958 mm30 D =0.1594 mm15 D =0.1450 mm10 C =1.980u C =0.921c Classification ASTM Poorly graded SAND (SP) AASHTO Fine Sand (A-3 (1)) Sample/Test Description Sand/Gravel Particle Shape : --- Sand/Gravel Hardness : ---
Page 218
G E O T E C H N I C A L R E P O R T V E S S E L R E S I D E N T I A L G R A N B Y , C O N N E C T I C U T F E B R U A R Y 1 6 , 2 0 2 3 GEI Consultants, Inc. Appendix C Recommended Material Specifications
Page 219
Recommended Material Specifications Vessel – 37 Hartford Avenue Granby, CT Per the Geotechnical Report, native sands excavated as part of earthwork activities can likely be re-used on site as Structural Fill or Ordinary Fill, provided they do not contain oversize, organic, or otherwise deleterious material and can meet the appropriate compaction requirements. Fill imported from off site should meet the attached gradation requirements. Fill placed within the building limits, within a 3-foot-wide zone outside foundation walls, under pavements, and behind retaining walls should meet the compaction requirements for Structural Fill. Backfill placed in non- structural areas should meet the compaction requirements for Ordinary Fill. Proposed borrow materials that fall slightly outside of these specifications may also be suitable for use, subject to review and approval by GEI. Structural Fill Imported Structural Fill should consist of hard, durable sand and gravel. It should be free of clay, organic matter, surface coatings, and other deleterious materials. Soil finer than the No. 200 sieve (the “fines”) should be non-plastic. Structural Fill shall meet the following gradation requirements: Sieve Size Percent Passing by Weight 3 inches 100 1 - ½ inch 55 – 100 No. 4 35 – 85 No. 16 20 – 65 No. 50 5 – 40 No. 200 (fines) 0 – 10 Structural Fill should be compacted in maximum 12-inch-thick, loose lifts to at least 95 percent of the maximum dry density determined in accordance with ASTM D1557 (Modified AASHTO Compaction). The moisture content should be held to within +/- 3 percent of optimum moisture content (as determined by ASTM D1557). Ordinary Fill Ordinary fill should consist of hard, durable sand and gravel, free of clay, organic matter, surface coatings, and other deleterious materials. Soil finer than the No. 200 sieve (the “fines”) should be nonplastic. Ordinary Fill shall meet the following gradation requirements :
Page 220
Sieve Size Percent Passing by Weight 6 inches 100 3 inches 80 – 100 No. 4 20 – 100 No. 200 (fines) 0 – 20 Ordinary fill should be compacted in maximum 12-inch-thick, loose lifts to at least 92 percent of the maximum dry density determined in accordance with ASTM D1557 (Modified AASHTO Compaction). The moisture content should be held to within +/- 3 percent of optimum moisture content (as determined by ASTM D1557). Crushed Stone Crushed Stone should consist of a ¾-inch size durable crushed rock or durable crushed gravel stone and shall conform to the requirements of the ConnDOT Form 818, Section M.01.01, No. 6. Crushed stone should be compacted with at least four passes of a vibratory compactor. Geotextile Fabric Geotextile fabric should be a non-woven fabric, consisting of Mirafi 140N or an approved equal product.
Page 221
G E O T E C H N I C A L R E P O R T V E S S E L R E S I D E N T I A L G R A N B Y , C O N N E C T I C U T F E B R U A R Y 1 6 , 2 0 2 3 GEI Consultants, Inc. Appendix D Infiltration/Permeability Testing Results
Page 222
WELL CALCULATIONS (W-1)
("Soil in casing in uniform soil," Lambe and Whitman, 1969.)
Diameter, sand pack 9.53 D (cm)
Diam., PVC riser 5.08 d (cm)
Length, slotted PVC 152 L (cm)
k'v/kv 1 Assumed
162 0
168 15
174 30
177 45
183 60
189 75
198 90
207 105
Vertical Perm.
k'v (in/hr)
153.87
196.29
187.43
9.61E-02
1.09E-01
Soil Permeability Calculations
Height
H (cm)
Time
t (seconds)
Vertical Perm.
k'v (cm/sec)
146 Hartford Ave.
Granby, CT
1.05E-01
5.10E-02
9.94E-02
1.38E-01
1.32E-01
AVERAGE
148.37
72.25
140.83
136.21
138.5
′ =
( 11
+ )
( − ) ln Page 223
WELL CALCULATIONS (W-2)
("Soil in casing in uniform soil," Lambe and Whitman, 1969.)
Diameter, sand pack 9.53 D (cm)
Diam., PVC riser 5.08 d (cm)
Length, slotted PVC 152 L (cm)
k'v/kv 1 Assumed
Height
H (cm)
Time
t (seconds)
131 0
146 15
152 30
165 45
180 60
189 75
198 90
201 105
1.38E-01 196.3
4.47E-02 63.4
AVERAGE 111.6
2.26E-01 319.7
2.60E-01 367.9
1.45E-01 206.0
3.22E-01 456.9
1.20E-01 169.6
Vertical Perm.
k'v (cm/sec)
Vertical Perm.
k'v (in/hr)
146 Hartford Ave.
Granby, CT
Soil Permeability Calculations
′ =
( 11
+ )
( − ) ln Page 224
Page 225
Page 226
Page 227
Page 228
Page 229
Page 230
ES-1 ES-2 DP-1 Hartford Avenue DP-2 Off-Site Wetlands Routing Diagram for 251219 - PRE Prepared by R Levesque Associates, Printed 5/28/2026 HydroCAD® 10.20-8a s/n 02175 © 2025 HydroCAD Software Solutions LLC Subcat Reach Pond Link
Page 231
251219 - PRE Printed 5/28/2026Prepared by R Levesque Associates Page 2HydroCAD® 10.20-8a s/n 02175 © 2025 HydroCAD Software Solutions LLC Rainfall Events Listing Event# Event Name Storm Type Curve Mode Duration (hours) B/B Depth (inches) AMC 1 2-Year Type III 24-hr Default 24.00 1 3.26 2 2 10-Year Type III 24-hr Default 24.00 1 4.86 2 3 25-Year Type III 24-hr Default 24.00 1 6.11 2 4 100-Year Type III 24-hr Default 24.00 1 8.63 2
Page 232
Type III 24-hr 2-Year Rainfall=3.26"251219 - PRE Printed 5/28/2026Prepared by R Levesque Associates Page 3HydroCAD® 10.20-8a s/n 02175 © 2025 HydroCAD Software Solutions LLC Time span=0.00-48.00 hrs, dt=0.03 hrs, 1601 points Runoff by SCS TR-20 method, UH=SCS, Weighted-Q Reach routing by Stor-Ind+Trans method - Pond routing by Stor-Ind method Runoff Area=14,006 sf 11.51% Impervious Runoff Depth=0.76"Subcatchment ES-1: Flow Length=100' Tc=10.0 min CN=WQ Runoff=0.2 cfs 891 cf Runoff Area=97,185 sf 7.57% Impervious Runoff Depth=0.33"Subcatchment ES-2: Flow Length=172' Tc=10.0 min CN=WQ Runoff=0.6 cfs 2,705 cf Inflow=0.2 cfs 891 cfLink DP-1: Hartford Avenue Primary=0.2 cfs 891 cf Inflow=0.6 cfs 2,705 cfLink DP-2: Off-Site Wetlands Primary=0.6 cfs 2,705 cf Total Runoff Area = 111,192 sf Runoff Volume = 3,595 cf Average Runoff Depth = 0.39" 91.94% Pervious = 102,227 sf 8.06% Impervious = 8,965 sf
Page 233
Type III 24-hr 2-Year Rainfall=3.26"251219 - PRE
Printed 5/28/2026Prepared by R Levesque Associates
Page 4HydroCAD® 10.20-8a s/n 02175 © 2025 HydroCAD Software Solutions LLC
Summary for Subcatchment ES-1:
Runoff = 0.2 cfs @ 12.16 hrs, Volume= 891 cf, Depth= 0.76"
Routed to Link DP-1 : Hartford Avenue
Runoff by SCS TR-20 method, UH=SCS, Weighted-Q, Time Span= 0.00-48.00 hrs, dt= 0.03 hrs
Type III 24-hr 2-Year Rainfall=3.26"
Area (sf) CN Description
12,395 61 >75% Grass cover, Good, HSG B
1,612 98 Paved parking, HSG B
14,006 Weighted Average
12,395 61 88.49% Pervious Area
1,612 98 11.51% Impervious Area
Tc Length Slope Velocity Capacity Description
(min) (feet) (ft/ft) (ft/sec) (cfs)
5.9 75 0.0420 0.21 Sheet Flow,
Grass: Short n= 0.150 P2= 3.11"
0.5 25 0.0100 0.78 Sheet Flow,
Smooth surfaces n= 0.011 P2= 3.11"
6.4 100 Total, Increased to minimum Tc = 10.0 min
Subcatchment ES-1:
Runoff
Hydrograph
Time (hours)
484644424038363432302826242220181614121086420
Flow (cfs)
0.2
0.19
0.18
0.17
0.16
0.15
0.14
0.13
0.12
0.11
0.1
0.09
0.08
0.07
0.06
0.05
0.04
0.03
0.02
0.01
0
Type III 24-hr
2-Year Rainfall=3.26"
Runoff Area=14,006 sf
Runoff Volume=891 cf
Runoff Depth=0.76"
Flow Length=100'
Tc=10.0 min
CN=WQ
0.2 cfs Page 234
Type III 24-hr 2-Year Rainfall=3.26"251219 - PRE
Printed 5/28/2026Prepared by R Levesque Associates
Page 5HydroCAD® 10.20-8a s/n 02175 © 2025 HydroCAD Software Solutions LLC
Summary for Subcatchment ES-2:
Runoff = 0.6 cfs @ 12.15 hrs, Volume= 2,705 cf, Depth= 0.33"
Routed to Link DP-2 : Off-Site Wetlands
Runoff by SCS TR-20 method, UH=SCS, Weighted-Q, Time Span= 0.00-48.00 hrs, dt= 0.03 hrs
Type III 24-hr 2-Year Rainfall=3.26"
Area (sf) CN Description
38,711 39 >75% Grass cover, Good, HSG A
17,267 61 >75% Grass cover, Good, HSG B
7,353 98 Paved parking, HSG B
26,193 30 Woods, Good, HSG A
7,661 55 Woods, Good, HSG B
97,185 Weighted Average
89,832 42 92.43% Pervious Area
7,353 98 7.57% Impervious Area
Tc Length Slope Velocity Capacity Description
(min) (feet) (ft/ft) (ft/sec) (cfs)
3.9 96 0.1870 0.41 Sheet Flow,
Grass: Short n= 0.150 P2= 3.11"
0.3 76 0.4800 4.85 Shallow Concentrated Flow,
Short Grass Pasture Kv= 7.0 fps
4.2 172 Total, Increased to minimum Tc = 10.0 min
Subcatchment ES-2:
Runoff
Hydrograph
Time (hours)
484644424038363432302826242220181614121086420
Flow (cfs)
0.65
0.6
0.55
0.5
0.45
0.4
0.35
0.3
0.25
0.2
0.15
0.1
0.05
0
Type III 24-hr
2-Year Rainfall=3.26"
Runoff Area=97,185 sf
Runoff Volume=2,705 cf
Runoff Depth=0.33"
Flow Length=172'
Tc=10.0 min
CN=WQ
0.6 cfs Page 235
Type III 24-hr 2-Year Rainfall=3.26"251219 - PRE Printed 5/28/2026Prepared by R Levesque Associates Page 6HydroCAD® 10.20-8a s/n 02175 © 2025 HydroCAD Software Solutions LLC Summary for Link DP-1: Hartford Avenue Inflow Area = 14,006 sf, 11.51% Impervious, Inflow Depth = 0.76" for 2-Year event Inflow = 0.2 cfs @ 12.16 hrs, Volume= 891 cf Primary = 0.2 cfs @ 12.16 hrs, Volume= 891 cf, Atten= 0%, Lag= 0.0 min Primary outflow = Inflow, Time Span= 0.00-48.00 hrs, dt= 0.03 hrs Link DP-1: Hartford Avenue Inflow Primary Hydrograph Time (hours) 484644424038363432302826242220181614121086420 Flow (cfs) 0.2 0.19 0.18 0.17 0.16 0.15 0.14 0.13 0.12 0.11 0.1 0.09 0.08 0.07 0.06 0.05 0.04 0.03 0.02 0.01 0 Inflow Area=14,006 sf 0.2 cfs 0.2 cfs
Page 236
Type III 24-hr 2-Year Rainfall=3.26"251219 - PRE Printed 5/28/2026Prepared by R Levesque Associates Page 7HydroCAD® 10.20-8a s/n 02175 © 2025 HydroCAD Software Solutions LLC Summary for Link DP-2: Off-Site Wetlands Inflow Area = 97,185 sf, 7.57% Impervious, Inflow Depth = 0.33" for 2-Year event Inflow = 0.6 cfs @ 12.15 hrs, Volume= 2,705 cf Primary = 0.6 cfs @ 12.15 hrs, Volume= 2,705 cf, Atten= 0%, Lag= 0.0 min Primary outflow = Inflow, Time Span= 0.00-48.00 hrs, dt= 0.03 hrs Link DP-2: Off-Site Wetlands Inflow Primary Hydrograph Time (hours) 484644424038363432302826242220181614121086420 Flow (cfs) 0.65 0.6 0.55 0.5 0.45 0.4 0.35 0.3 0.25 0.2 0.15 0.1 0.05 0 Inflow Area=97,185 sf 0.6 cfs 0.6 cfs
Page 237
Type III 24-hr 10-Year Rainfall=4.86"251219 - PRE Printed 5/28/2026Prepared by R Levesque Associates Page 8HydroCAD® 10.20-8a s/n 02175 © 2025 HydroCAD Software Solutions LLC Time span=0.00-48.00 hrs, dt=0.03 hrs, 1601 points Runoff by SCS TR-20 method, UH=SCS, Weighted-Q Reach routing by Stor-Ind+Trans method - Pond routing by Stor-Ind method Runoff Area=14,006 sf 11.51% Impervious Runoff Depth=1.67"Subcatchment ES-1: Flow Length=100' Tc=10.0 min CN=WQ Runoff=0.5 cfs 1,949 cf Runoff Area=97,185 sf 7.57% Impervious Runoff Depth=0.72"Subcatchment ES-2: Flow Length=172' Tc=10.0 min CN=WQ Runoff=1.3 cfs 5,825 cf Inflow=0.5 cfs 1,949 cfLink DP-1: Hartford Avenue Primary=0.5 cfs 1,949 cf Inflow=1.3 cfs 5,825 cfLink DP-2: Off-Site Wetlands Primary=1.3 cfs 5,825 cf Total Runoff Area = 111,192 sf Runoff Volume = 7,774 cf Average Runoff Depth = 0.84" 91.94% Pervious = 102,227 sf 8.06% Impervious = 8,965 sf
Page 238
Type III 24-hr 10-Year Rainfall=4.86"251219 - PRE
Printed 5/28/2026Prepared by R Levesque Associates
Page 9HydroCAD® 10.20-8a s/n 02175 © 2025 HydroCAD Software Solutions LLC
Summary for Subcatchment ES-1:
Runoff = 0.5 cfs @ 12.15 hrs, Volume= 1,949 cf, Depth= 1.67"
Routed to Link DP-1 : Hartford Avenue
Runoff by SCS TR-20 method, UH=SCS, Weighted-Q, Time Span= 0.00-48.00 hrs, dt= 0.03 hrs
Type III 24-hr 10-Year Rainfall=4.86"
Area (sf) CN Description
12,395 61 >75% Grass cover, Good, HSG B
1,612 98 Paved parking, HSG B
14,006 Weighted Average
12,395 61 88.49% Pervious Area
1,612 98 11.51% Impervious Area
Tc Length Slope Velocity Capacity Description
(min) (feet) (ft/ft) (ft/sec) (cfs)
5.9 75 0.0420 0.21 Sheet Flow,
Grass: Short n= 0.150 P2= 3.11"
0.5 25 0.0100 0.78 Sheet Flow,
Smooth surfaces n= 0.011 P2= 3.11"
6.4 100 Total, Increased to minimum Tc = 10.0 min
Subcatchment ES-1:
Runoff
Hydrograph
Time (hours)
484644424038363432302826242220181614121086420
Flow (cfs)
0.5
0.45
0.4
0.35
0.3
0.25
0.2
0.15
0.1
0.05
0
Type III 24-hr
10-Year Rainfall=4.86"
Runoff Area=14,006 sf
Runoff Volume=1,949 cf
Runoff Depth=1.67"
Flow Length=100'
Tc=10.0 min
CN=WQ
0.5 cfs Page 239
Type III 24-hr 10-Year Rainfall=4.86"251219 - PRE
Printed 5/28/2026Prepared by R Levesque Associates
Page 10HydroCAD® 10.20-8a s/n 02175 © 2025 HydroCAD Software Solutions LLC
Summary for Subcatchment ES-2:
Runoff = 1.3 cfs @ 12.15 hrs, Volume= 5,825 cf, Depth= 0.72"
Routed to Link DP-2 : Off-Site Wetlands
Runoff by SCS TR-20 method, UH=SCS, Weighted-Q, Time Span= 0.00-48.00 hrs, dt= 0.03 hrs
Type III 24-hr 10-Year Rainfall=4.86"
Area (sf) CN Description
38,711 39 >75% Grass cover, Good, HSG A
17,267 61 >75% Grass cover, Good, HSG B
7,353 98 Paved parking, HSG B
26,193 30 Woods, Good, HSG A
7,661 55 Woods, Good, HSG B
97,185 Weighted Average
89,832 42 92.43% Pervious Area
7,353 98 7.57% Impervious Area
Tc Length Slope Velocity Capacity Description
(min) (feet) (ft/ft) (ft/sec) (cfs)
3.9 96 0.1870 0.41 Sheet Flow,
Grass: Short n= 0.150 P2= 3.11"
0.3 76 0.4800 4.85 Shallow Concentrated Flow,
Short Grass Pasture Kv= 7.0 fps
4.2 172 Total, Increased to minimum Tc = 10.0 min
Subcatchment ES-2:
Runoff
Hydrograph
Time (hours)
484644424038363432302826242220181614121086420
Flow (cfs)
1
0
Type III 24-hr
10-Year Rainfall=4.86"
Runoff Area=97,185 sf
Runoff Volume=5,825 cf
Runoff Depth=0.72"
Flow Length=172'
Tc=10.0 min
CN=WQ
1.3 cfs Page 240
Type III 24-hr 10-Year Rainfall=4.86"251219 - PRE Printed 5/28/2026Prepared by R Levesque Associates Page 11HydroCAD® 10.20-8a s/n 02175 © 2025 HydroCAD Software Solutions LLC Summary for Link DP-1: Hartford Avenue Inflow Area = 14,006 sf, 11.51% Impervious, Inflow Depth = 1.67" for 10-Year event Inflow = 0.5 cfs @ 12.15 hrs, Volume= 1,949 cf Primary = 0.5 cfs @ 12.15 hrs, Volume= 1,949 cf, Atten= 0%, Lag= 0.0 min Primary outflow = Inflow, Time Span= 0.00-48.00 hrs, dt= 0.03 hrs Link DP-1: Hartford Avenue Inflow Primary Hydrograph Time (hours) 484644424038363432302826242220181614121086420 Flow (cfs) 0.5 0.45 0.4 0.35 0.3 0.25 0.2 0.15 0.1 0.05 0 Inflow Area=14,006 sf 0.5 cfs 0.5 cfs
Page 241
Type III 24-hr 10-Year Rainfall=4.86"251219 - PRE Printed 5/28/2026Prepared by R Levesque Associates Page 12HydroCAD® 10.20-8a s/n 02175 © 2025 HydroCAD Software Solutions LLC Summary for Link DP-2: Off-Site Wetlands Inflow Area = 97,185 sf, 7.57% Impervious, Inflow Depth = 0.72" for 10-Year event Inflow = 1.3 cfs @ 12.15 hrs, Volume= 5,825 cf Primary = 1.3 cfs @ 12.15 hrs, Volume= 5,825 cf, Atten= 0%, Lag= 0.0 min Primary outflow = Inflow, Time Span= 0.00-48.00 hrs, dt= 0.03 hrs Link DP-2: Off-Site Wetlands Inflow Primary Hydrograph Time (hours) 484644424038363432302826242220181614121086420 Flow (cfs) 1 0 Inflow Area=97,185 sf 1.3 cfs 1.3 cfs
Page 242
Type III 24-hr 25-Year Rainfall=6.11"251219 - PRE Printed 5/28/2026Prepared by R Levesque Associates Page 13HydroCAD® 10.20-8a s/n 02175 © 2025 HydroCAD Software Solutions LLC Time span=0.00-48.00 hrs, dt=0.03 hrs, 1601 points Runoff by SCS TR-20 method, UH=SCS, Weighted-Q Reach routing by Stor-Ind+Trans method - Pond routing by Stor-Ind method Runoff Area=14,006 sf 11.51% Impervious Runoff Depth=2.52"Subcatchment ES-1: Flow Length=100' Tc=10.0 min CN=WQ Runoff=0.8 cfs 2,937 cf Runoff Area=97,185 sf 7.57% Impervious Runoff Depth=1.15"Subcatchment ES-2: Flow Length=172' Tc=10.0 min CN=WQ Runoff=2.0 cfs 9,323 cf Inflow=0.8 cfs 2,937 cfLink DP-1: Hartford Avenue Primary=0.8 cfs 2,937 cf Inflow=2.0 cfs 9,323 cfLink DP-2: Off-Site Wetlands Primary=2.0 cfs 9,323 cf Total Runoff Area = 111,192 sf Runoff Volume = 12,260 cf Average Runoff Depth = 1.32" 91.94% Pervious = 102,227 sf 8.06% Impervious = 8,965 sf
Page 243
Type III 24-hr 25-Year Rainfall=6.11"251219 - PRE
Printed 5/28/2026Prepared by R Levesque Associates
Page 14HydroCAD® 10.20-8a s/n 02175 © 2025 HydroCAD Software Solutions LLC
Summary for Subcatchment ES-1:
Runoff = 0.8 cfs @ 12.15 hrs, Volume= 2,937 cf, Depth= 2.52"
Routed to Link DP-1 : Hartford Avenue
Runoff by SCS TR-20 method, UH=SCS, Weighted-Q, Time Span= 0.00-48.00 hrs, dt= 0.03 hrs
Type III 24-hr 25-Year Rainfall=6.11"
Area (sf) CN Description
12,395 61 >75% Grass cover, Good, HSG B
1,612 98 Paved parking, HSG B
14,006 Weighted Average
12,395 61 88.49% Pervious Area
1,612 98 11.51% Impervious Area
Tc Length Slope Velocity Capacity Description
(min) (feet) (ft/ft) (ft/sec) (cfs)
5.9 75 0.0420 0.21 Sheet Flow,
Grass: Short n= 0.150 P2= 3.11"
0.5 25 0.0100 0.78 Sheet Flow,
Smooth surfaces n= 0.011 P2= 3.11"
6.4 100 Total, Increased to minimum Tc = 10.0 min
Subcatchment ES-1:
Runoff
Hydrograph
Time (hours)
484644424038363432302826242220181614121086420
Flow (cfs)
0.85
0.8
0.75
0.7
0.65
0.6
0.55
0.5
0.45
0.4
0.35
0.3
0.25
0.2
0.15
0.1
0.05
0
Type III 24-hr
25-Year Rainfall=6.11"
Runoff Area=14,006 sf
Runoff Volume=2,937 cf
Runoff Depth=2.52"
Flow Length=100'
Tc=10.0 min
CN=WQ
0.8 cfs Page 244
Type III 24-hr 25-Year Rainfall=6.11"251219 - PRE
Printed 5/28/2026Prepared by R Levesque Associates
Page 15HydroCAD® 10.20-8a s/n 02175 © 2025 HydroCAD Software Solutions LLC
Summary for Subcatchment ES-2:
Runoff = 2.0 cfs @ 12.15 hrs, Volume= 9,323 cf, Depth= 1.15"
Routed to Link DP-2 : Off-Site Wetlands
Runoff by SCS TR-20 method, UH=SCS, Weighted-Q, Time Span= 0.00-48.00 hrs, dt= 0.03 hrs
Type III 24-hr 25-Year Rainfall=6.11"
Area (sf) CN Description
38,711 39 >75% Grass cover, Good, HSG A
17,267 61 >75% Grass cover, Good, HSG B
7,353 98 Paved parking, HSG B
26,193 30 Woods, Good, HSG A
7,661 55 Woods, Good, HSG B
97,185 Weighted Average
89,832 42 92.43% Pervious Area
7,353 98 7.57% Impervious Area
Tc Length Slope Velocity Capacity Description
(min) (feet) (ft/ft) (ft/sec) (cfs)
3.9 96 0.1870 0.41 Sheet Flow,
Grass: Short n= 0.150 P2= 3.11"
0.3 76 0.4800 4.85 Shallow Concentrated Flow,
Short Grass Pasture Kv= 7.0 fps
4.2 172 Total, Increased to minimum Tc = 10.0 min
Subcatchment ES-2:
Runoff
Hydrograph
Time (hours)
484644424038363432302826242220181614121086420
Flow (cfs)
2
1
0
Type III 24-hr
25-Year Rainfall=6.11"
Runoff Area=97,185 sf
Runoff Volume=9,323 cf
Runoff Depth=1.15"
Flow Length=172'
Tc=10.0 min
CN=WQ
2.0 cfs Page 245
Type III 24-hr 25-Year Rainfall=6.11"251219 - PRE Printed 5/28/2026Prepared by R Levesque Associates Page 16HydroCAD® 10.20-8a s/n 02175 © 2025 HydroCAD Software Solutions LLC Summary for Link DP-1: Hartford Avenue Inflow Area = 14,006 sf, 11.51% Impervious, Inflow Depth = 2.52" for 25-Year event Inflow = 0.8 cfs @ 12.15 hrs, Volume= 2,937 cf Primary = 0.8 cfs @ 12.15 hrs, Volume= 2,937 cf, Atten= 0%, Lag= 0.0 min Primary outflow = Inflow, Time Span= 0.00-48.00 hrs, dt= 0.03 hrs Link DP-1: Hartford Avenue Inflow Primary Hydrograph Time (hours) 484644424038363432302826242220181614121086420 Flow (cfs) 0.85 0.8 0.75 0.7 0.65 0.6 0.55 0.5 0.45 0.4 0.35 0.3 0.25 0.2 0.15 0.1 0.05 0 Inflow Area=14,006 sf 0.8 cfs 0.8 cfs
Page 246
Type III 24-hr 25-Year Rainfall=6.11"251219 - PRE Printed 5/28/2026Prepared by R Levesque Associates Page 17HydroCAD® 10.20-8a s/n 02175 © 2025 HydroCAD Software Solutions LLC Summary for Link DP-2: Off-Site Wetlands Inflow Area = 97,185 sf, 7.57% Impervious, Inflow Depth = 1.15" for 25-Year event Inflow = 2.0 cfs @ 12.15 hrs, Volume= 9,323 cf Primary = 2.0 cfs @ 12.15 hrs, Volume= 9,323 cf, Atten= 0%, Lag= 0.0 min Primary outflow = Inflow, Time Span= 0.00-48.00 hrs, dt= 0.03 hrs Link DP-2: Off-Site Wetlands Inflow Primary Hydrograph Time (hours) 484644424038363432302826242220181614121086420 Flow (cfs) 2 1 0 Inflow Area=97,185 sf 2.0 cfs 2.0 cfs
Page 247
Type III 24-hr 100-Year Rainfall=8.63"251219 - PRE Printed 5/28/2026Prepared by R Levesque Associates Page 18HydroCAD® 10.20-8a s/n 02175 © 2025 HydroCAD Software Solutions LLC Time span=0.00-48.00 hrs, dt=0.03 hrs, 1601 points Runoff by SCS TR-20 method, UH=SCS, Weighted-Q Reach routing by Stor-Ind+Trans method - Pond routing by Stor-Ind method Runoff Area=14,006 sf 11.51% Impervious Runoff Depth=4.44"Subcatchment ES-1: Flow Length=100' Tc=10.0 min CN=WQ Runoff=1.4 cfs 5,188 cf Runoff Area=97,185 sf 7.57% Impervious Runoff Depth=2.31"Subcatchment ES-2: Flow Length=172' Tc=10.0 min CN=WQ Runoff=4.3 cfs 18,731 cf Inflow=1.4 cfs 5,188 cfLink DP-1: Hartford Avenue Primary=1.4 cfs 5,188 cf Inflow=4.3 cfs 18,731 cfLink DP-2: Off-Site Wetlands Primary=4.3 cfs 18,731 cf Total Runoff Area = 111,192 sf Runoff Volume = 23,919 cf Average Runoff Depth = 2.58" 91.94% Pervious = 102,227 sf 8.06% Impervious = 8,965 sf
Page 248
Type III 24-hr 100-Year Rainfall=8.63"251219 - PRE
Printed 5/28/2026Prepared by R Levesque Associates
Page 19HydroCAD® 10.20-8a s/n 02175 © 2025 HydroCAD Software Solutions LLC
Summary for Subcatchment ES-1:
Runoff = 1.4 cfs @ 12.14 hrs, Volume= 5,188 cf, Depth= 4.44"
Routed to Link DP-1 : Hartford Avenue
Runoff by SCS TR-20 method, UH=SCS, Weighted-Q, Time Span= 0.00-48.00 hrs, dt= 0.03 hrs
Type III 24-hr 100-Year Rainfall=8.63"
Area (sf) CN Description
12,395 61 >75% Grass cover, Good, HSG B
1,612 98 Paved parking, HSG B
14,006 Weighted Average
12,395 61 88.49% Pervious Area
1,612 98 11.51% Impervious Area
Tc Length Slope Velocity Capacity Description
(min) (feet) (ft/ft) (ft/sec) (cfs)
5.9 75 0.0420 0.21 Sheet Flow,
Grass: Short n= 0.150 P2= 3.11"
0.5 25 0.0100 0.78 Sheet Flow,
Smooth surfaces n= 0.011 P2= 3.11"
6.4 100 Total, Increased to minimum Tc = 10.0 min
Subcatchment ES-1:
Runoff
Hydrograph
Time (hours)
484644424038363432302826242220181614121086420
Flow (cfs)
1
0
Type III 24-hr
100-Year Rainfall=8.63"
Runoff Area=14,006 sf
Runoff Volume=5,188 cf
Runoff Depth=4.44"
Flow Length=100'
Tc=10.0 min
CN=WQ
1.4 cfs Page 249
Type III 24-hr 100-Year Rainfall=8.63"251219 - PRE
Printed 5/28/2026Prepared by R Levesque Associates
Page 20HydroCAD® 10.20-8a s/n 02175 © 2025 HydroCAD Software Solutions LLC
Summary for Subcatchment ES-2:
Runoff = 4.3 cfs @ 12.15 hrs, Volume= 18,731 cf, Depth= 2.31"
Routed to Link DP-2 : Off-Site Wetlands
Runoff by SCS TR-20 method, UH=SCS, Weighted-Q, Time Span= 0.00-48.00 hrs, dt= 0.03 hrs
Type III 24-hr 100-Year Rainfall=8.63"
Area (sf) CN Description
38,711 39 >75% Grass cover, Good, HSG A
17,267 61 >75% Grass cover, Good, HSG B
7,353 98 Paved parking, HSG B
26,193 30 Woods, Good, HSG A
7,661 55 Woods, Good, HSG B
97,185 Weighted Average
89,832 42 92.43% Pervious Area
7,353 98 7.57% Impervious Area
Tc Length Slope Velocity Capacity Description
(min) (feet) (ft/ft) (ft/sec) (cfs)
3.9 96 0.1870 0.41 Sheet Flow,
Grass: Short n= 0.150 P2= 3.11"
0.3 76 0.4800 4.85 Shallow Concentrated Flow,
Short Grass Pasture Kv= 7.0 fps
4.2 172 Total, Increased to minimum Tc = 10.0 min
Subcatchment ES-2:
Runoff
Hydrograph
Time (hours)
484644424038363432302826242220181614121086420
Flow (cfs)
4
3
2
1
0
Type III 24-hr
100-Year Rainfall=8.63"
Runoff Area=97,185 sf
Runoff Volume=18,731 cf
Runoff Depth=2.31"
Flow Length=172'
Tc=10.0 min
CN=WQ
4.3 cfs Page 250
Type III 24-hr 100-Year Rainfall=8.63"251219 - PRE Printed 5/28/2026Prepared by R Levesque Associates Page 21HydroCAD® 10.20-8a s/n 02175 © 2025 HydroCAD Software Solutions LLC Summary for Link DP-1: Hartford Avenue Inflow Area = 14,006 sf, 11.51% Impervious, Inflow Depth = 4.44" for 100-Year event Inflow = 1.4 cfs @ 12.14 hrs, Volume= 5,188 cf Primary = 1.4 cfs @ 12.14 hrs, Volume= 5,188 cf, Atten= 0%, Lag= 0.0 min Primary outflow = Inflow, Time Span= 0.00-48.00 hrs, dt= 0.03 hrs Link DP-1: Hartford Avenue Inflow Primary Hydrograph Time (hours) 484644424038363432302826242220181614121086420 Flow (cfs) 1 0 Inflow Area=14,006 sf 1.4 cfs 1.4 cfs
Page 251
Type III 24-hr 100-Year Rainfall=8.63"251219 - PRE Printed 5/28/2026Prepared by R Levesque Associates Page 22HydroCAD® 10.20-8a s/n 02175 © 2025 HydroCAD Software Solutions LLC Summary for Link DP-2: Off-Site Wetlands Inflow Area = 97,185 sf, 7.57% Impervious, Inflow Depth = 2.31" for 100-Year event Inflow = 4.3 cfs @ 12.15 hrs, Volume= 18,731 cf Primary = 4.3 cfs @ 12.15 hrs, Volume= 18,731 cf, Atten= 0%, Lag= 0.0 min Primary outflow = Inflow, Time Span= 0.00-48.00 hrs, dt= 0.03 hrs Link DP-2: Off-Site Wetlands Inflow Primary Hydrograph Time (hours) 484644424038363432302826242220181614121086420 Flow (cfs) 4 3 2 1 0 Inflow Area=97,185 sf 4.3 cfs 4.3 cfs
Page 252
Page 253
PS-1 PS-2a PS-2b 1P Subsurface Infiltration Basin DP-1 Hartford Avenue DP-2 Off-Site Wetlands Routing Diagram for 251219 - POST Prepared by R Levesque Associates, Printed 6/1/2026 HydroCAD® 10.20-8a s/n 02175 © 2025 HydroCAD Software Solutions LLC Subcat Reach Pond Link
Page 254
251219 - POST Printed 6/1/2026Prepared by R Levesque Associates Page 2HydroCAD® 10.20-8a s/n 02175 © 2025 HydroCAD Software Solutions LLC Rainfall Events Listing Event# Event Name Storm Type Curve Mode Duration (hours) B/B Depth (inches) AMC 1 2-Year Type III 24-hr Default 24.00 1 3.26 2 2 10-Year Type III 24-hr Default 24.00 1 4.86 2 3 25-Year Type III 24-hr Default 24.00 1 6.11 2 4 100-Year Type III 24-hr Default 24.00 1 8.63 2
Page 255
Type III 24-hr 2-Year Rainfall=3.26"251219 - POST Printed 6/1/2026Prepared by R Levesque Associates Page 3HydroCAD® 10.20-8a s/n 02175 © 2025 HydroCAD Software Solutions LLC Time span=0.00-48.00 hrs, dt=0.03 hrs, 1601 points Runoff by SCS TR-20 method, UH=SCS, Weighted-Q Reach routing by Stor-Ind+Trans method - Pond routing by Stor-Ind method Runoff Area=12,127 sf 20.66% Impervious Runoff Depth=1.00"Subcatchment PS-1: Flow Length=100' Tc=10.0 min CN=WQ Runoff=0.2 cfs 1,008 cf Runoff Area=30,117 sf 75.92% Impervious Runoff Depth=2.40"Subcatchment PS-2a: Tc=10.0 min CN=WQ Runoff=1.5 cfs 6,036 cf Runoff Area=68,949 sf 0.57% Impervious Runoff Depth=0.09"Subcatchment PS-2b: Flow Length=172' Tc=10.0 min CN=WQ Runoff=0.1 cfs 502 cf Peak Elev=195.50' Storage=1,234 cf Inflow=1.5 cfs 6,036 cfPond 1P: Subsurface Infiltration Basin Discarded=0.4 cfs 6,036 cf Primary=0.0 cfs 0 cf Outflow=0.4 cfs 6,036 cf Inflow=0.2 cfs 1,008 cfLink DP-1: Hartford Avenue Primary=0.2 cfs 1,008 cf Inflow=0.1 cfs 502 cfLink DP-2: Off-Site Wetlands Primary=0.1 cfs 502 cf Total Runoff Area = 111,193 sf Runoff Volume = 7,546 cf Average Runoff Depth = 0.81" 76.83% Pervious = 85,427 sf 23.17% Impervious = 25,767 sf
Page 256
Type III 24-hr 2-Year Rainfall=3.26"251219 - POST
Printed 6/1/2026Prepared by R Levesque Associates
Page 4HydroCAD® 10.20-8a s/n 02175 © 2025 HydroCAD Software Solutions LLC
Summary for Subcatchment PS-1:
Runoff = 0.2 cfs @ 12.15 hrs, Volume= 1,008 cf, Depth= 1.00"
Routed to Link DP-1 : Hartford Avenue
Runoff by SCS TR-20 method, UH=SCS, Weighted-Q, Time Span= 0.00-48.00 hrs, dt= 0.03 hrs
Type III 24-hr 2-Year Rainfall=3.26"
Area (sf) CN Description
9,622 61 >75% Grass cover, Good, HSG B
2,505 98 Paved parking, HSG B
12,127 Weighted Average
9,622 61 79.34% Pervious Area
2,505 98 20.66% Impervious Area
Tc Length Slope Velocity Capacity Description
(min) (feet) (ft/ft) (ft/sec) (cfs)
5.9 75 0.0420 0.21 Sheet Flow,
Grass: Short n= 0.150 P2= 3.11"
0.5 25 0.0100 0.78 Sheet Flow,
Smooth surfaces n= 0.011 P2= 3.11"
6.4 100 Total, Increased to minimum Tc = 10.0 min
Subcatchment PS-1:
Runoff
Hydrograph
Time (hours)
484644424038363432302826242220181614121086420
Flow (cfs)
0.24
0.23
0.22
0.21
0.2
0.19
0.18
0.17
0.16
0.15
0.14
0.13
0.12
0.11
0.1
0.09
0.08
0.07
0.06
0.05
0.04
0.03
0.02
0.01
0
Type III 24-hr
2-Year Rainfall=3.26"
Runoff Area=12,127 sf
Runoff Volume=1,008 cf
Runoff Depth=1.00"
Flow Length=100'
Tc=10.0 min
CN=WQ
0.2 cfs Page 257
Type III 24-hr 2-Year Rainfall=3.26"251219 - POST
Printed 6/1/2026Prepared by R Levesque Associates
Page 5HydroCAD® 10.20-8a s/n 02175 © 2025 HydroCAD Software Solutions LLC
Summary for Subcatchment PS-2a:
Runoff = 1.5 cfs @ 12.14 hrs, Volume= 6,036 cf, Depth= 2.40"
Routed to Pond 1P : Subsurface Infiltration Basin
Runoff by SCS TR-20 method, UH=SCS, Weighted-Q, Time Span= 0.00-48.00 hrs, dt= 0.03 hrs
Type III 24-hr 2-Year Rainfall=3.26"
Area (sf) CN Description
19 39 >75% Grass cover, Good, HSG A
6,322 61 >75% Grass cover, Good, HSG B
9,107 98 Paved parking, HSG A
8,312 98 Paved parking, HSG B
5,447 98 Roofs, HSG B
911 55 Woods, Good, HSG B
30,117 Weighted Average
7,252 60 24.08% Pervious Area
22,865 98 75.92% Impervious Area
Tc Length Slope Velocity Capacity Description
(min) (feet) (ft/ft) (ft/sec) (cfs)
10.0 Direct Entry,
Subcatchment PS-2a:
Runoff
Hydrograph
Time (hours)
484644424038363432302826242220181614121086420
Flow (cfs)
1
0
Type III 24-hr
2-Year Rainfall=3.26"
Runoff Area=30,117 sf
Runoff Volume=6,036 cf
Runoff Depth=2.40"
Tc=10.0 min
CN=WQ
1.5 cfs Page 258
Type III 24-hr 2-Year Rainfall=3.26"251219 - POST
Printed 6/1/2026Prepared by R Levesque Associates
Page 6HydroCAD® 10.20-8a s/n 02175 © 2025 HydroCAD Software Solutions LLC
Summary for Subcatchment PS-2b:
Runoff = 0.1 cfs @ 12.19 hrs, Volume= 502 cf, Depth= 0.09"
Routed to Link DP-2 : Off-Site Wetlands
Runoff by SCS TR-20 method, UH=SCS, Weighted-Q, Time Span= 0.00-48.00 hrs, dt= 0.03 hrs
Type III 24-hr 2-Year Rainfall=3.26"
Area (sf) CN Description
29,350 39 >75% Grass cover, Good, HSG A
6,505 61 >75% Grass cover, Good, HSG B
235 98 Paved parking, HSG A
161 98 Paved parking, HSG B
26,193 30 Woods, Good, HSG A
6,504 55 Woods, Good, HSG B
68,949 Weighted Average
68,553 39 99.43% Pervious Area
396 98 0.57% Impervious Area
Tc Length Slope Velocity Capacity Description
(min) (feet) (ft/ft) (ft/sec) (cfs)
3.9 96 0.1870 0.41 Sheet Flow,
Grass: Short n= 0.150 P2= 3.11"
0.3 76 0.4300 4.59 Shallow Concentrated Flow,
Short Grass Pasture Kv= 7.0 fps
4.2 172 Total, Increased to minimum Tc = 10.0 min
Subcatchment PS-2b:
Runoff
Hydrograph
Time (hours)
484644424038363432302826242220181614121086420
Flow (cfs)
0.085
0.08
0.075
0.07
0.065
0.06
0.055
0.05
0.045
0.04
0.035
0.03
0.025
0.02
0.015
0.01
0.005
0
Type III 24-hr
2-Year Rainfall=3.26"
Runoff Area=68,949 sf
Runoff Volume=502 cf
Runoff Depth=0.09"
Flow Length=172'
Tc=10.0 min
CN=WQ
0.1 cfs Page 259
Type III 24-hr 2-Year Rainfall=3.26"251219 - POST
Printed 6/1/2026Prepared by R Levesque Associates
Page 7HydroCAD® 10.20-8a s/n 02175 © 2025 HydroCAD Software Solutions LLC
Summary for Pond 1P: Subsurface Infiltration Basin
Inflow Area = 30,117 sf, 75.92% Impervious, Inflow Depth = 2.40" for 2-Year event
Inflow = 1.5 cfs @ 12.14 hrs, Volume= 6,036 cf
Outflow = 0.4 cfs @ 11.82 hrs, Volume= 6,036 cf, Atten= 74%, Lag= 0.0 min
Discarded = 0.4 cfs @ 11.82 hrs, Volume= 6,036 cf
Primary = 0.0 cfs @ 0.00 hrs, Volume= 0 cf
Routed to Link DP-2 : Off-Site Wetlands
Routing by Stor-Ind method, Time Span= 0.00-48.00 hrs, dt= 0.03 hrs
Peak Elev= 195.50' @ 12.55 hrs Surf.Area= 2,011 sf Storage= 1,234 cf
Plug-Flow detention time= 15.7 min calculated for 6,032 cf (100% of inflow)
Center-of-Mass det. time= 15.7 min ( 782.5 - 766.8 )
Volume Invert Avail.Storage Storage Description
#1A 194.50' 1,915 cf 15.25'W x 131.87'L x 3.75'H Field A
7,541 cf Overall - 2,753 cf Embedded = 4,789 cf x 40.0% Voids
#2A 195.00' 2,753 cf ADS_StormTech SC-800 +Cap x 54 Inside #1
Effective Size= 45.0"W x 33.0"H => 7.11 sf x 7.12'L = 50.6 cf
Overall Size= 51.0"W x 33.0"H x 7.55'L with 0.43' Overlap
54 Chambers in 3 Rows
Cap Storage= 3.4 cf x 2 x 3 rows = 20.5 cf
4,668 cf Total Available Storage
Storage Group A created with Chamber Wizard
Device Routing Invert Outlet Devices
#1 Primary 195.00' 12.0" Round Culvert
L= 45.0' RCP, groove end projecting, Ke= 0.200
Inlet / Outlet Invert= 195.00' / 194.10' S= 0.0200 '/' Cc= 0.900
n= 0.013, Flow Area= 0.79 sf
#2 Device 1 197.25' 4.0' long Sharp-Crested Rectangular Weir 2 End Contraction(s)
#3 Device 1 196.75' 12.0" W x 3.0" H Vert. Orifice C= 0.600
Limited to weir flow at low heads
#4 Discarded 194.50' 8.270 in/hr Exfiltration over Surface area Phase-In= 0.01'
Discarded OutFlow Max=0.4 cfs @ 11.82 hrs HW=194.54' (Free Discharge)
4=Exfiltration (Exfiltration Controls 0.4 cfs)
Primary OutFlow Max=0.0 cfs @ 0.00 hrs HW=194.50' (Free Discharge)
1=Culvert ( Controls 0.0 cfs)
2=Sharp-Crested Rectangular Weir ( Controls 0.0 cfs)
3=Orifice ( Controls 0.0 cfs)Page 260
Type III 24-hr 2-Year Rainfall=3.26"251219 - POST Printed 6/1/2026Prepared by R Levesque Associates Page 8HydroCAD® 10.20-8a s/n 02175 © 2025 HydroCAD Software Solutions LLC Pond 1P: Subsurface Infiltration Basin Inflow Outflow Discarded Primary Hydrograph Time (hours) 484644424038363432302826242220181614121086420 Flow (cfs) 1 0 Inflow Area=30,117 sf Peak Elev=195.50' Storage=1,234 cf 1.5 cfs 0.4 cfs 0.4 cfs 0.0 cfs
Page 261
Type III 24-hr 2-Year Rainfall=3.26"251219 - POST Printed 6/1/2026Prepared by R Levesque Associates Page 9HydroCAD® 10.20-8a s/n 02175 © 2025 HydroCAD Software Solutions LLC Summary for Link DP-1: Hartford Avenue Inflow Area = 12,127 sf, 20.66% Impervious, Inflow Depth = 1.00" for 2-Year event Inflow = 0.2 cfs @ 12.15 hrs, Volume= 1,008 cf Primary = 0.2 cfs @ 12.15 hrs, Volume= 1,008 cf, Atten= 0%, Lag= 0.0 min Primary outflow = Inflow, Time Span= 0.00-48.00 hrs, dt= 0.03 hrs Link DP-1: Hartford Avenue Inflow Primary Hydrograph Time (hours) 484644424038363432302826242220181614121086420 Flow (cfs) 0.24 0.23 0.22 0.21 0.2 0.19 0.18 0.17 0.16 0.15 0.14 0.13 0.12 0.11 0.1 0.09 0.08 0.07 0.06 0.05 0.04 0.03 0.02 0.01 0 Inflow Area=12,127 sf 0.2 cfs 0.2 cfs
Page 262
Type III 24-hr 2-Year Rainfall=3.26"251219 - POST Printed 6/1/2026Prepared by R Levesque Associates Page 10HydroCAD® 10.20-8a s/n 02175 © 2025 HydroCAD Software Solutions LLC Summary for Link DP-2: Off-Site Wetlands Inflow Area = 99,066 sf, 23.48% Impervious, Inflow Depth = 0.06" for 2-Year event Inflow = 0.1 cfs @ 12.19 hrs, Volume= 502 cf Primary = 0.1 cfs @ 12.19 hrs, Volume= 502 cf, Atten= 0%, Lag= 0.0 min Primary outflow = Inflow, Time Span= 0.00-48.00 hrs, dt= 0.03 hrs Link DP-2: Off-Site Wetlands Inflow Primary Hydrograph Time (hours) 484644424038363432302826242220181614121086420 Flow (cfs) 0.085 0.08 0.075 0.07 0.065 0.06 0.055 0.05 0.045 0.04 0.035 0.03 0.025 0.02 0.015 0.01 0.005 0 Inflow Area=99,066 sf 0.1 cfs 0.1 cfs
Page 263
Type III 24-hr 10-Year Rainfall=4.86"251219 - POST Printed 6/1/2026Prepared by R Levesque Associates Page 11HydroCAD® 10.20-8a s/n 02175 © 2025 HydroCAD Software Solutions LLC Time span=0.00-48.00 hrs, dt=0.03 hrs, 1601 points Runoff by SCS TR-20 method, UH=SCS, Weighted-Q Reach routing by Stor-Ind+Trans method - Pond routing by Stor-Ind method Runoff Area=12,127 sf 20.66% Impervious Runoff Depth=1.98"Subcatchment PS-1: Flow Length=100' Tc=10.0 min CN=WQ Runoff=0.5 cfs 1,996 cf Runoff Area=30,117 sf 75.92% Impervious Runoff Depth=3.81"Subcatchment PS-2a: Tc=10.0 min CN=WQ Runoff=2.4 cfs 9,556 cf Runoff Area=68,949 sf 0.57% Impervious Runoff Depth=0.31"Subcatchment PS-2b: Flow Length=172' Tc=10.0 min CN=WQ Runoff=0.3 cfs 1,769 cf Peak Elev=196.40' Storage=2,634 cf Inflow=2.4 cfs 9,556 cfPond 1P: Subsurface Infiltration Basin Discarded=0.4 cfs 9,556 cf Primary=0.0 cfs 0 cf Outflow=0.4 cfs 9,556 cf Inflow=0.5 cfs 1,996 cfLink DP-1: Hartford Avenue Primary=0.5 cfs 1,996 cf Inflow=0.3 cfs 1,769 cfLink DP-2: Off-Site Wetlands Primary=0.3 cfs 1,769 cf Total Runoff Area = 111,193 sf Runoff Volume = 13,322 cf Average Runoff Depth = 1.44" 76.83% Pervious = 85,427 sf 23.17% Impervious = 25,767 sf
Page 264
Type III 24-hr 10-Year Rainfall=4.86"251219 - POST
Printed 6/1/2026Prepared by R Levesque Associates
Page 12HydroCAD® 10.20-8a s/n 02175 © 2025 HydroCAD Software Solutions LLC
Summary for Subcatchment PS-1:
Runoff = 0.5 cfs @ 12.15 hrs, Volume= 1,996 cf, Depth= 1.98"
Routed to Link DP-1 : Hartford Avenue
Runoff by SCS TR-20 method, UH=SCS, Weighted-Q, Time Span= 0.00-48.00 hrs, dt= 0.03 hrs
Type III 24-hr 10-Year Rainfall=4.86"
Area (sf) CN Description
9,622 61 >75% Grass cover, Good, HSG B
2,505 98 Paved parking, HSG B
12,127 Weighted Average
9,622 61 79.34% Pervious Area
2,505 98 20.66% Impervious Area
Tc Length Slope Velocity Capacity Description
(min) (feet) (ft/ft) (ft/sec) (cfs)
5.9 75 0.0420 0.21 Sheet Flow,
Grass: Short n= 0.150 P2= 3.11"
0.5 25 0.0100 0.78 Sheet Flow,
Smooth surfaces n= 0.011 P2= 3.11"
6.4 100 Total, Increased to minimum Tc = 10.0 min
Subcatchment PS-1:
Runoff
Hydrograph
Time (hours)
484644424038363432302826242220181614121086420
Flow (cfs)
0.55
0.5
0.45
0.4
0.35
0.3
0.25
0.2
0.15
0.1
0.05
0
Type III 24-hr
10-Year Rainfall=4.86"
Runoff Area=12,127 sf
Runoff Volume=1,996 cf
Runoff Depth=1.98"
Flow Length=100'
Tc=10.0 min
CN=WQ
0.5 cfs Page 265
Type III 24-hr 10-Year Rainfall=4.86"251219 - POST
Printed 6/1/2026Prepared by R Levesque Associates
Page 13HydroCAD® 10.20-8a s/n 02175 © 2025 HydroCAD Software Solutions LLC
Summary for Subcatchment PS-2a:
Runoff = 2.4 cfs @ 12.14 hrs, Volume= 9,556 cf, Depth= 3.81"
Routed to Pond 1P : Subsurface Infiltration Basin
Runoff by SCS TR-20 method, UH=SCS, Weighted-Q, Time Span= 0.00-48.00 hrs, dt= 0.03 hrs
Type III 24-hr 10-Year Rainfall=4.86"
Area (sf) CN Description
19 39 >75% Grass cover, Good, HSG A
6,322 61 >75% Grass cover, Good, HSG B
9,107 98 Paved parking, HSG A
8,312 98 Paved parking, HSG B
5,447 98 Roofs, HSG B
911 55 Woods, Good, HSG B
30,117 Weighted Average
7,252 60 24.08% Pervious Area
22,865 98 75.92% Impervious Area
Tc Length Slope Velocity Capacity Description
(min) (feet) (ft/ft) (ft/sec) (cfs)
10.0 Direct Entry,
Subcatchment PS-2a:
Runoff
Hydrograph
Time (hours)
484644424038363432302826242220181614121086420
Flow (cfs)
2
1
0
Type III 24-hr
10-Year Rainfall=4.86"
Runoff Area=30,117 sf
Runoff Volume=9,556 cf
Runoff Depth=3.81"
Tc=10.0 min
CN=WQ
2.4 cfs Page 266
Type III 24-hr 10-Year Rainfall=4.86"251219 - POST
Printed 6/1/2026Prepared by R Levesque Associates
Page 14HydroCAD® 10.20-8a s/n 02175 © 2025 HydroCAD Software Solutions LLC
Summary for Subcatchment PS-2b:
Runoff = 0.3 cfs @ 12.16 hrs, Volume= 1,769 cf, Depth= 0.31"
Routed to Link DP-2 : Off-Site Wetlands
Runoff by SCS TR-20 method, UH=SCS, Weighted-Q, Time Span= 0.00-48.00 hrs, dt= 0.03 hrs
Type III 24-hr 10-Year Rainfall=4.86"
Area (sf) CN Description
29,350 39 >75% Grass cover, Good, HSG A
6,505 61 >75% Grass cover, Good, HSG B
235 98 Paved parking, HSG A
161 98 Paved parking, HSG B
26,193 30 Woods, Good, HSG A
6,504 55 Woods, Good, HSG B
68,949 Weighted Average
68,553 39 99.43% Pervious Area
396 98 0.57% Impervious Area
Tc Length Slope Velocity Capacity Description
(min) (feet) (ft/ft) (ft/sec) (cfs)
3.9 96 0.1870 0.41 Sheet Flow,
Grass: Short n= 0.150 P2= 3.11"
0.3 76 0.4300 4.59 Shallow Concentrated Flow,
Short Grass Pasture Kv= 7.0 fps
4.2 172 Total, Increased to minimum Tc = 10.0 min
Subcatchment PS-2b:
Runoff
Hydrograph
Time (hours)
484644424038363432302826242220181614121086420
Flow (cfs)
0.34
0.32
0.3
0.28
0.26
0.24
0.22
0.2
0.18
0.16
0.14
0.12
0.1
0.08
0.06
0.04
0.02
0
Type III 24-hr
10-Year Rainfall=4.86"
Runoff Area=68,949 sf
Runoff Volume=1,769 cf
Runoff Depth=0.31"
Flow Length=172'
Tc=10.0 min
CN=WQ
0.3 cfs Page 267
Type III 24-hr 10-Year Rainfall=4.86"251219 - POST
Printed 6/1/2026Prepared by R Levesque Associates
Page 15HydroCAD® 10.20-8a s/n 02175 © 2025 HydroCAD Software Solutions LLC
Summary for Pond 1P: Subsurface Infiltration Basin
Inflow Area = 30,117 sf, 75.92% Impervious, Inflow Depth = 3.81" for 10-Year event
Inflow = 2.4 cfs @ 12.14 hrs, Volume= 9,556 cf
Outflow = 0.4 cfs @ 11.70 hrs, Volume= 9,556 cf, Atten= 84%, Lag= 0.0 min
Discarded = 0.4 cfs @ 11.70 hrs, Volume= 9,556 cf
Primary = 0.0 cfs @ 0.00 hrs, Volume= 0 cf
Routed to Link DP-2 : Off-Site Wetlands
Routing by Stor-Ind method, Time Span= 0.00-48.00 hrs, dt= 0.03 hrs
Peak Elev= 196.40' @ 12.68 hrs Surf.Area= 2,011 sf Storage= 2,634 cf
Plug-Flow detention time= 40.0 min calculated for 9,550 cf (100% of inflow)
Center-of-Mass det. time= 40.0 min ( 802.2 - 762.2 )
Volume Invert Avail.Storage Storage Description
#1A 194.50' 1,915 cf 15.25'W x 131.87'L x 3.75'H Field A
7,541 cf Overall - 2,753 cf Embedded = 4,789 cf x 40.0% Voids
#2A 195.00' 2,753 cf ADS_StormTech SC-800 +Cap x 54 Inside #1
Effective Size= 45.0"W x 33.0"H => 7.11 sf x 7.12'L = 50.6 cf
Overall Size= 51.0"W x 33.0"H x 7.55'L with 0.43' Overlap
54 Chambers in 3 Rows
Cap Storage= 3.4 cf x 2 x 3 rows = 20.5 cf
4,668 cf Total Available Storage
Storage Group A created with Chamber Wizard
Device Routing Invert Outlet Devices
#1 Primary 195.00' 12.0" Round Culvert
L= 45.0' RCP, groove end projecting, Ke= 0.200
Inlet / Outlet Invert= 195.00' / 194.10' S= 0.0200 '/' Cc= 0.900
n= 0.013, Flow Area= 0.79 sf
#2 Device 1 197.25' 4.0' long Sharp-Crested Rectangular Weir 2 End Contraction(s)
#3 Device 1 196.75' 12.0" W x 3.0" H Vert. Orifice C= 0.600
Limited to weir flow at low heads
#4 Discarded 194.50' 8.270 in/hr Exfiltration over Surface area Phase-In= 0.01'
Discarded OutFlow Max=0.4 cfs @ 11.70 hrs HW=194.54' (Free Discharge)
4=Exfiltration (Exfiltration Controls 0.4 cfs)
Primary OutFlow Max=0.0 cfs @ 0.00 hrs HW=194.50' (Free Discharge)
1=Culvert ( Controls 0.0 cfs)
2=Sharp-Crested Rectangular Weir ( Controls 0.0 cfs)
3=Orifice ( Controls 0.0 cfs)Page 268
Type III 24-hr 10-Year Rainfall=4.86"251219 - POST Printed 6/1/2026Prepared by R Levesque Associates Page 16HydroCAD® 10.20-8a s/n 02175 © 2025 HydroCAD Software Solutions LLC Pond 1P: Subsurface Infiltration Basin Inflow Outflow Discarded Primary Hydrograph Time (hours) 484644424038363432302826242220181614121086420 Flow (cfs) 2 1 0 Inflow Area=30,117 sf Peak Elev=196.40' Storage=2,634 cf 2.4 cfs 0.4 cfs 0.4 cfs 0.0 cfs
Page 269
Type III 24-hr 10-Year Rainfall=4.86"251219 - POST Printed 6/1/2026Prepared by R Levesque Associates Page 17HydroCAD® 10.20-8a s/n 02175 © 2025 HydroCAD Software Solutions LLC Summary for Link DP-1: Hartford Avenue Inflow Area = 12,127 sf, 20.66% Impervious, Inflow Depth = 1.98" for 10-Year event Inflow = 0.5 cfs @ 12.15 hrs, Volume= 1,996 cf Primary = 0.5 cfs @ 12.15 hrs, Volume= 1,996 cf, Atten= 0%, Lag= 0.0 min Primary outflow = Inflow, Time Span= 0.00-48.00 hrs, dt= 0.03 hrs Link DP-1: Hartford Avenue Inflow Primary Hydrograph Time (hours) 484644424038363432302826242220181614121086420 Flow (cfs) 0.55 0.5 0.45 0.4 0.35 0.3 0.25 0.2 0.15 0.1 0.05 0 Inflow Area=12,127 sf 0.5 cfs 0.5 cfs
Page 270
Type III 24-hr 10-Year Rainfall=4.86"251219 - POST Printed 6/1/2026Prepared by R Levesque Associates Page 18HydroCAD® 10.20-8a s/n 02175 © 2025 HydroCAD Software Solutions LLC Summary for Link DP-2: Off-Site Wetlands Inflow Area = 99,066 sf, 23.48% Impervious, Inflow Depth = 0.21" for 10-Year event Inflow = 0.3 cfs @ 12.16 hrs, Volume= 1,769 cf Primary = 0.3 cfs @ 12.16 hrs, Volume= 1,769 cf, Atten= 0%, Lag= 0.0 min Primary outflow = Inflow, Time Span= 0.00-48.00 hrs, dt= 0.03 hrs Link DP-2: Off-Site Wetlands Inflow Primary Hydrograph Time (hours) 484644424038363432302826242220181614121086420 Flow (cfs) 0.34 0.32 0.3 0.28 0.26 0.24 0.22 0.2 0.18 0.16 0.14 0.12 0.1 0.08 0.06 0.04 0.02 0 Inflow Area=99,066 sf 0.3 cfs 0.3 cfs
Page 271
Type III 24-hr 25-Year Rainfall=6.11"251219 - POST Printed 6/1/2026Prepared by R Levesque Associates Page 19HydroCAD® 10.20-8a s/n 02175 © 2025 HydroCAD Software Solutions LLC Time span=0.00-48.00 hrs, dt=0.03 hrs, 1601 points Runoff by SCS TR-20 method, UH=SCS, Weighted-Q Reach routing by Stor-Ind+Trans method - Pond routing by Stor-Ind method Runoff Area=12,127 sf 20.66% Impervious Runoff Depth=2.86"Subcatchment PS-1: Flow Length=100' Tc=10.0 min CN=WQ Runoff=0.7 cfs 2,893 cf Runoff Area=30,117 sf 75.92% Impervious Runoff Depth=4.94"Subcatchment PS-2a: Tc=10.0 min CN=WQ Runoff=3.1 cfs 12,405 cf Runoff Area=68,949 sf 0.57% Impervious Runoff Depth=0.61"Subcatchment PS-2b: Flow Length=172' Tc=10.0 min CN=WQ Runoff=0.6 cfs 3,529 cf Peak Elev=197.03' Storage=3,503 cf Inflow=3.1 cfs 12,405 cfPond 1P: Subsurface Infiltration Basin Discarded=0.4 cfs 11,757 cf Primary=0.5 cfs 647 cf Outflow=0.8 cfs 12,405 cf Inflow=0.7 cfs 2,893 cfLink DP-1: Hartford Avenue Primary=0.7 cfs 2,893 cf Inflow=0.8 cfs 4,177 cfLink DP-2: Off-Site Wetlands Primary=0.8 cfs 4,177 cf Total Runoff Area = 111,193 sf Runoff Volume = 18,827 cf Average Runoff Depth = 2.03" 76.83% Pervious = 85,427 sf 23.17% Impervious = 25,767 sf
Page 272
Type III 24-hr 25-Year Rainfall=6.11"251219 - POST
Printed 6/1/2026Prepared by R Levesque Associates
Page 20HydroCAD® 10.20-8a s/n 02175 © 2025 HydroCAD Software Solutions LLC
Summary for Subcatchment PS-1:
Runoff = 0.7 cfs @ 12.14 hrs, Volume= 2,893 cf, Depth= 2.86"
Routed to Link DP-1 : Hartford Avenue
Runoff by SCS TR-20 method, UH=SCS, Weighted-Q, Time Span= 0.00-48.00 hrs, dt= 0.03 hrs
Type III 24-hr 25-Year Rainfall=6.11"
Area (sf) CN Description
9,622 61 >75% Grass cover, Good, HSG B
2,505 98 Paved parking, HSG B
12,127 Weighted Average
9,622 61 79.34% Pervious Area
2,505 98 20.66% Impervious Area
Tc Length Slope Velocity Capacity Description
(min) (feet) (ft/ft) (ft/sec) (cfs)
5.9 75 0.0420 0.21 Sheet Flow,
Grass: Short n= 0.150 P2= 3.11"
0.5 25 0.0100 0.78 Sheet Flow,
Smooth surfaces n= 0.011 P2= 3.11"
6.4 100 Total, Increased to minimum Tc = 10.0 min
Subcatchment PS-1:
Runoff
Hydrograph
Time (hours)
484644424038363432302826242220181614121086420
Flow (cfs)
0.8
0.75
0.7
0.65
0.6
0.55
0.5
0.45
0.4
0.35
0.3
0.25
0.2
0.15
0.1
0.05
0
Type III 24-hr
25-Year Rainfall=6.11"
Runoff Area=12,127 sf
Runoff Volume=2,893 cf
Runoff Depth=2.86"
Flow Length=100'
Tc=10.0 min
CN=WQ
0.7 cfs Page 273
Type III 24-hr 25-Year Rainfall=6.11"251219 - POST
Printed 6/1/2026Prepared by R Levesque Associates
Page 21HydroCAD® 10.20-8a s/n 02175 © 2025 HydroCAD Software Solutions LLC
Summary for Subcatchment PS-2a:
Runoff = 3.1 cfs @ 12.14 hrs, Volume= 12,405 cf, Depth= 4.94"
Routed to Pond 1P : Subsurface Infiltration Basin
Runoff by SCS TR-20 method, UH=SCS, Weighted-Q, Time Span= 0.00-48.00 hrs, dt= 0.03 hrs
Type III 24-hr 25-Year Rainfall=6.11"
Area (sf) CN Description
19 39 >75% Grass cover, Good, HSG A
6,322 61 >75% Grass cover, Good, HSG B
9,107 98 Paved parking, HSG A
8,312 98 Paved parking, HSG B
5,447 98 Roofs, HSG B
911 55 Woods, Good, HSG B
30,117 Weighted Average
7,252 60 24.08% Pervious Area
22,865 98 75.92% Impervious Area
Tc Length Slope Velocity Capacity Description
(min) (feet) (ft/ft) (ft/sec) (cfs)
10.0 Direct Entry,
Subcatchment PS-2a:
Runoff
Hydrograph
Time (hours)
484644424038363432302826242220181614121086420
Flow (cfs)
3
2
1
0
Type III 24-hr
25-Year Rainfall=6.11"
Runoff Area=30,117 sf
Runoff Volume=12,405 cf
Runoff Depth=4.94"
Tc=10.0 min
CN=WQ
3.1 cfs Page 274
Type III 24-hr 25-Year Rainfall=6.11"251219 - POST
Printed 6/1/2026Prepared by R Levesque Associates
Page 22HydroCAD® 10.20-8a s/n 02175 © 2025 HydroCAD Software Solutions LLC
Summary for Subcatchment PS-2b:
Runoff = 0.6 cfs @ 12.17 hrs, Volume= 3,529 cf, Depth= 0.61"
Routed to Link DP-2 : Off-Site Wetlands
Runoff by SCS TR-20 method, UH=SCS, Weighted-Q, Time Span= 0.00-48.00 hrs, dt= 0.03 hrs
Type III 24-hr 25-Year Rainfall=6.11"
Area (sf) CN Description
29,350 39 >75% Grass cover, Good, HSG A
6,505 61 >75% Grass cover, Good, HSG B
235 98 Paved parking, HSG A
161 98 Paved parking, HSG B
26,193 30 Woods, Good, HSG A
6,504 55 Woods, Good, HSG B
68,949 Weighted Average
68,553 39 99.43% Pervious Area
396 98 0.57% Impervious Area
Tc Length Slope Velocity Capacity Description
(min) (feet) (ft/ft) (ft/sec) (cfs)
3.9 96 0.1870 0.41 Sheet Flow,
Grass: Short n= 0.150 P2= 3.11"
0.3 76 0.4300 4.59 Shallow Concentrated Flow,
Short Grass Pasture Kv= 7.0 fps
4.2 172 Total, Increased to minimum Tc = 10.0 min
Subcatchment PS-2b:
Runoff
Hydrograph
Time (hours)
484644424038363432302826242220181614121086420
Flow (cfs)
0.65
0.6
0.55
0.5
0.45
0.4
0.35
0.3
0.25
0.2
0.15
0.1
0.05
0
Type III 24-hr
25-Year Rainfall=6.11"
Runoff Area=68,949 sf
Runoff Volume=3,529 cf
Runoff Depth=0.61"
Flow Length=172'
Tc=10.0 min
CN=WQ
0.6 cfs Page 275
Type III 24-hr 25-Year Rainfall=6.11"251219 - POST
Printed 6/1/2026Prepared by R Levesque Associates
Page 23HydroCAD® 10.20-8a s/n 02175 © 2025 HydroCAD Software Solutions LLC
Summary for Pond 1P: Subsurface Infiltration Basin
Inflow Area = 30,117 sf, 75.92% Impervious, Inflow Depth = 4.94" for 25-Year event
Inflow = 3.1 cfs @ 12.14 hrs, Volume= 12,405 cf
Outflow = 0.8 cfs @ 12.54 hrs, Volume= 12,405 cf, Atten= 73%, Lag= 24.1 min
Discarded = 0.4 cfs @ 11.61 hrs, Volume= 11,757 cf
Primary = 0.5 cfs @ 12.54 hrs, Volume= 647 cf
Routed to Link DP-2 : Off-Site Wetlands
Routing by Stor-Ind method, Time Span= 0.00-48.00 hrs, dt= 0.03 hrs
Peak Elev= 197.03' @ 12.54 hrs Surf.Area= 2,011 sf Storage= 3,503 cf
Plug-Flow detention time= 50.8 min calculated for 12,397 cf (100% of inflow)
Center-of-Mass det. time= 50.8 min ( 810.7 - 760.0 )
Volume Invert Avail.Storage Storage Description
#1A 194.50' 1,915 cf 15.25'W x 131.87'L x 3.75'H Field A
7,541 cf Overall - 2,753 cf Embedded = 4,789 cf x 40.0% Voids
#2A 195.00' 2,753 cf ADS_StormTech SC-800 +Cap x 54 Inside #1
Effective Size= 45.0"W x 33.0"H => 7.11 sf x 7.12'L = 50.6 cf
Overall Size= 51.0"W x 33.0"H x 7.55'L with 0.43' Overlap
54 Chambers in 3 Rows
Cap Storage= 3.4 cf x 2 x 3 rows = 20.5 cf
4,668 cf Total Available Storage
Storage Group A created with Chamber Wizard
Device Routing Invert Outlet Devices
#1 Primary 195.00' 12.0" Round Culvert
L= 45.0' RCP, groove end projecting, Ke= 0.200
Inlet / Outlet Invert= 195.00' / 194.10' S= 0.0200 '/' Cc= 0.900
n= 0.013, Flow Area= 0.79 sf
#2 Device 1 197.25' 4.0' long Sharp-Crested Rectangular Weir 2 End Contraction(s)
#3 Device 1 196.75' 12.0" W x 3.0" H Vert. Orifice C= 0.600
Limited to weir flow at low heads
#4 Discarded 194.50' 8.270 in/hr Exfiltration over Surface area Phase-In= 0.01'
Discarded OutFlow Max=0.4 cfs @ 11.61 hrs HW=194.54' (Free Discharge)
4=Exfiltration (Exfiltration Controls 0.4 cfs)
Primary OutFlow Max=0.5 cfs @ 12.54 hrs HW=197.03' (Free Discharge)
1=Culvert (Passes 0.5 cfs of 5.4 cfs potential flow)
2=Sharp-Crested Rectangular Weir ( Controls 0.0 cfs)
3=Orifice (Orifice Controls 0.5 cfs @ 1.83 fps)Page 276
Type III 24-hr 25-Year Rainfall=6.11"251219 - POST Printed 6/1/2026Prepared by R Levesque Associates Page 24HydroCAD® 10.20-8a s/n 02175 © 2025 HydroCAD Software Solutions LLC Pond 1P: Subsurface Infiltration Basin Inflow Outflow Discarded Primary Hydrograph Time (hours) 484644424038363432302826242220181614121086420 Flow (cfs) 3 2 1 0 Inflow Area=30,117 sf Peak Elev=197.03' Storage=3,503 cf 3.1 cfs 0.8 cfs 0.4 cfs 0.5 cfs
Page 277
Type III 24-hr 25-Year Rainfall=6.11"251219 - POST Printed 6/1/2026Prepared by R Levesque Associates Page 25HydroCAD® 10.20-8a s/n 02175 © 2025 HydroCAD Software Solutions LLC Summary for Link DP-1: Hartford Avenue Inflow Area = 12,127 sf, 20.66% Impervious, Inflow Depth = 2.86" for 25-Year event Inflow = 0.7 cfs @ 12.14 hrs, Volume= 2,893 cf Primary = 0.7 cfs @ 12.14 hrs, Volume= 2,893 cf, Atten= 0%, Lag= 0.0 min Primary outflow = Inflow, Time Span= 0.00-48.00 hrs, dt= 0.03 hrs Link DP-1: Hartford Avenue Inflow Primary Hydrograph Time (hours) 484644424038363432302826242220181614121086420 Flow (cfs) 0.8 0.75 0.7 0.65 0.6 0.55 0.5 0.45 0.4 0.35 0.3 0.25 0.2 0.15 0.1 0.05 0 Inflow Area=12,127 sf 0.7 cfs 0.7 cfs
Page 278
Type III 24-hr 25-Year Rainfall=6.11"251219 - POST Printed 6/1/2026Prepared by R Levesque Associates Page 26HydroCAD® 10.20-8a s/n 02175 © 2025 HydroCAD Software Solutions LLC Summary for Link DP-2: Off-Site Wetlands Inflow Area = 99,066 sf, 23.48% Impervious, Inflow Depth = 0.51" for 25-Year event Inflow = 0.8 cfs @ 12.49 hrs, Volume= 4,177 cf Primary = 0.8 cfs @ 12.49 hrs, Volume= 4,177 cf, Atten= 0%, Lag= 0.0 min Primary outflow = Inflow, Time Span= 0.00-48.00 hrs, dt= 0.03 hrs Link DP-2: Off-Site Wetlands Inflow Primary Hydrograph Time (hours) 484644424038363432302826242220181614121086420 Flow (cfs) 0.85 0.8 0.75 0.7 0.65 0.6 0.55 0.5 0.45 0.4 0.35 0.3 0.25 0.2 0.15 0.1 0.05 0 Inflow Area=99,066 sf 0.8 cfs 0.8 cfs
Page 279
Type III 24-hr 100-Year Rainfall=8.63"251219 - POST Printed 6/1/2026Prepared by R Levesque Associates Page 27HydroCAD® 10.20-8a s/n 02175 © 2025 HydroCAD Software Solutions LLC Time span=0.00-48.00 hrs, dt=0.03 hrs, 1601 points Runoff by SCS TR-20 method, UH=SCS, Weighted-Q Reach routing by Stor-Ind+Trans method - Pond routing by Stor-Ind method Runoff Area=12,127 sf 20.66% Impervious Runoff Depth=4.85"Subcatchment PS-1: Flow Length=100' Tc=10.0 min CN=WQ Runoff=1.3 cfs 4,904 cf Runoff Area=30,117 sf 75.92% Impervious Runoff Depth=7.29"Subcatchment PS-2a: Tc=10.0 min CN=WQ Runoff=4.5 cfs 18,305 cf Runoff Area=68,949 sf 0.57% Impervious Runoff Depth=1.55"Subcatchment PS-2b: Flow Length=172' Tc=10.0 min CN=WQ Runoff=1.8 cfs 8,913 cf Peak Elev=197.51' Storage=4,053 cf Inflow=4.5 cfs 18,305 cfPond 1P: Subsurface Infiltration Basin Discarded=0.4 cfs 14,728 cf Primary=2.6 cfs 3,577 cf Outflow=3.0 cfs 18,305 cf Inflow=1.3 cfs 4,904 cfLink DP-1: Hartford Avenue Primary=1.3 cfs 4,904 cf Inflow=4.2 cfs 12,490 cfLink DP-2: Off-Site Wetlands Primary=4.2 cfs 12,490 cf Total Runoff Area = 111,193 sf Runoff Volume = 32,122 cf Average Runoff Depth = 3.47" 76.83% Pervious = 85,427 sf 23.17% Impervious = 25,767 sf
Page 280
Type III 24-hr 100-Year Rainfall=8.63"251219 - POST
Printed 6/1/2026Prepared by R Levesque Associates
Page 28HydroCAD® 10.20-8a s/n 02175 © 2025 HydroCAD Software Solutions LLC
Summary for Subcatchment PS-1:
Runoff = 1.3 cfs @ 12.14 hrs, Volume= 4,904 cf, Depth= 4.85"
Routed to Link DP-1 : Hartford Avenue
Runoff by SCS TR-20 method, UH=SCS, Weighted-Q, Time Span= 0.00-48.00 hrs, dt= 0.03 hrs
Type III 24-hr 100-Year Rainfall=8.63"
Area (sf) CN Description
9,622 61 >75% Grass cover, Good, HSG B
2,505 98 Paved parking, HSG B
12,127 Weighted Average
9,622 61 79.34% Pervious Area
2,505 98 20.66% Impervious Area
Tc Length Slope Velocity Capacity Description
(min) (feet) (ft/ft) (ft/sec) (cfs)
5.9 75 0.0420 0.21 Sheet Flow,
Grass: Short n= 0.150 P2= 3.11"
0.5 25 0.0100 0.78 Sheet Flow,
Smooth surfaces n= 0.011 P2= 3.11"
6.4 100 Total, Increased to minimum Tc = 10.0 min
Subcatchment PS-1:
Runoff
Hydrograph
Time (hours)
484644424038363432302826242220181614121086420
Flow (cfs)
1
0
Type III 24-hr
100-Year Rainfall=8.63"
Runoff Area=12,127 sf
Runoff Volume=4,904 cf
Runoff Depth=4.85"
Flow Length=100'
Tc=10.0 min
CN=WQ
1.3 cfs Page 281
Type III 24-hr 100-Year Rainfall=8.63"251219 - POST
Printed 6/1/2026Prepared by R Levesque Associates
Page 29HydroCAD® 10.20-8a s/n 02175 © 2025 HydroCAD Software Solutions LLC
Summary for Subcatchment PS-2a:
Runoff = 4.5 cfs @ 12.13 hrs, Volume= 18,305 cf, Depth= 7.29"
Routed to Pond 1P : Subsurface Infiltration Basin
Runoff by SCS TR-20 method, UH=SCS, Weighted-Q, Time Span= 0.00-48.00 hrs, dt= 0.03 hrs
Type III 24-hr 100-Year Rainfall=8.63"
Area (sf) CN Description
19 39 >75% Grass cover, Good, HSG A
6,322 61 >75% Grass cover, Good, HSG B
9,107 98 Paved parking, HSG A
8,312 98 Paved parking, HSG B
5,447 98 Roofs, HSG B
911 55 Woods, Good, HSG B
30,117 Weighted Average
7,252 60 24.08% Pervious Area
22,865 98 75.92% Impervious Area
Tc Length Slope Velocity Capacity Description
(min) (feet) (ft/ft) (ft/sec) (cfs)
10.0 Direct Entry,
Subcatchment PS-2a:
Runoff
Hydrograph
Time (hours)
484644424038363432302826242220181614121086420
Flow (cfs)
5
4
3
2
1
0
Type III 24-hr
100-Year Rainfall=8.63"
Runoff Area=30,117 sf
Runoff Volume=18,305 cf
Runoff Depth=7.29"
Tc=10.0 min
CN=WQ
4.5 cfs Page 282
Type III 24-hr 100-Year Rainfall=8.63"251219 - POST
Printed 6/1/2026Prepared by R Levesque Associates
Page 30HydroCAD® 10.20-8a s/n 02175 © 2025 HydroCAD Software Solutions LLC
Summary for Subcatchment PS-2b:
Runoff = 1.8 cfs @ 12.16 hrs, Volume= 8,913 cf, Depth= 1.55"
Routed to Link DP-2 : Off-Site Wetlands
Runoff by SCS TR-20 method, UH=SCS, Weighted-Q, Time Span= 0.00-48.00 hrs, dt= 0.03 hrs
Type III 24-hr 100-Year Rainfall=8.63"
Area (sf) CN Description
29,350 39 >75% Grass cover, Good, HSG A
6,505 61 >75% Grass cover, Good, HSG B
235 98 Paved parking, HSG A
161 98 Paved parking, HSG B
26,193 30 Woods, Good, HSG A
6,504 55 Woods, Good, HSG B
68,949 Weighted Average
68,553 39 99.43% Pervious Area
396 98 0.57% Impervious Area
Tc Length Slope Velocity Capacity Description
(min) (feet) (ft/ft) (ft/sec) (cfs)
3.9 96 0.1870 0.41 Sheet Flow,
Grass: Short n= 0.150 P2= 3.11"
0.3 76 0.4300 4.59 Shallow Concentrated Flow,
Short Grass Pasture Kv= 7.0 fps
4.2 172 Total, Increased to minimum Tc = 10.0 min
Subcatchment PS-2b:
Runoff
Hydrograph
Time (hours)
484644424038363432302826242220181614121086420
Flow (cfs)
2
1
0
Type III 24-hr
100-Year Rainfall=8.63"
Runoff Area=68,949 sf
Runoff Volume=8,913 cf
Runoff Depth=1.55"
Flow Length=172'
Tc=10.0 min
CN=WQ
1.8 cfs Page 283
Type III 24-hr 100-Year Rainfall=8.63"251219 - POST
Printed 6/1/2026Prepared by R Levesque Associates
Page 31HydroCAD® 10.20-8a s/n 02175 © 2025 HydroCAD Software Solutions LLC
Summary for Pond 1P: Subsurface Infiltration Basin
Inflow Area = 30,117 sf, 75.92% Impervious, Inflow Depth = 7.29" for 100-Year event
Inflow = 4.5 cfs @ 12.13 hrs, Volume= 18,305 cf
Outflow = 3.0 cfs @ 12.27 hrs, Volume= 18,305 cf, Atten= 33%, Lag= 7.9 min
Discarded = 0.4 cfs @ 11.25 hrs, Volume= 14,728 cf
Primary = 2.6 cfs @ 12.27 hrs, Volume= 3,577 cf
Routed to Link DP-2 : Off-Site Wetlands
Routing by Stor-Ind method, Time Span= 0.00-48.00 hrs, dt= 0.03 hrs
Peak Elev= 197.51' @ 12.27 hrs Surf.Area= 2,011 sf Storage= 4,053 cf
Plug-Flow detention time= 46.7 min calculated for 18,293 cf (100% of inflow)
Center-of-Mass det. time= 46.7 min ( 803.5 - 756.8 )
Volume Invert Avail.Storage Storage Description
#1A 194.50' 1,915 cf 15.25'W x 131.87'L x 3.75'H Field A
7,541 cf Overall - 2,753 cf Embedded = 4,789 cf x 40.0% Voids
#2A 195.00' 2,753 cf ADS_StormTech SC-800 +Cap x 54 Inside #1
Effective Size= 45.0"W x 33.0"H => 7.11 sf x 7.12'L = 50.6 cf
Overall Size= 51.0"W x 33.0"H x 7.55'L with 0.43' Overlap
54 Chambers in 3 Rows
Cap Storage= 3.4 cf x 2 x 3 rows = 20.5 cf
4,668 cf Total Available Storage
Storage Group A created with Chamber Wizard
Device Routing Invert Outlet Devices
#1 Primary 195.00' 12.0" Round Culvert
L= 45.0' RCP, groove end projecting, Ke= 0.200
Inlet / Outlet Invert= 195.00' / 194.10' S= 0.0200 '/' Cc= 0.900
n= 0.013, Flow Area= 0.79 sf
#2 Device 1 197.25' 4.0' long Sharp-Crested Rectangular Weir 2 End Contraction(s)
#3 Device 1 196.75' 12.0" W x 3.0" H Vert. Orifice C= 0.600
Limited to weir flow at low heads
#4 Discarded 194.50' 8.270 in/hr Exfiltration over Surface area Phase-In= 0.01'
Discarded OutFlow Max=0.4 cfs @ 11.25 hrs HW=194.54' (Free Discharge)
4=Exfiltration (Exfiltration Controls 0.4 cfs)
Primary OutFlow Max=2.6 cfs @ 12.27 hrs HW=197.51' (Free Discharge)
1=Culvert (Passes 2.6 cfs of 6.0 cfs potential flow)
2=Sharp-Crested Rectangular Weir (Weir Controls 1.7 cfs @ 1.66 fps)
3=Orifice (Orifice Controls 1.0 cfs @ 3.82 fps)Page 284
Type III 24-hr 100-Year Rainfall=8.63"251219 - POST Printed 6/1/2026Prepared by R Levesque Associates Page 32HydroCAD® 10.20-8a s/n 02175 © 2025 HydroCAD Software Solutions LLC Pond 1P: Subsurface Infiltration Basin Inflow Outflow Discarded Primary Hydrograph Time (hours) 484644424038363432302826242220181614121086420 Flow (cfs) 5 4 3 2 1 0 Inflow Area=30,117 sf Peak Elev=197.51' Storage=4,053 cf 4.5 cfs 3.0 cfs 0.4 cfs 2.6 cfs
Page 285
Type III 24-hr 100-Year Rainfall=8.63"251219 - POST Printed 6/1/2026Prepared by R Levesque Associates Page 33HydroCAD® 10.20-8a s/n 02175 © 2025 HydroCAD Software Solutions LLC Summary for Link DP-1: Hartford Avenue Inflow Area = 12,127 sf, 20.66% Impervious, Inflow Depth = 4.85" for 100-Year event Inflow = 1.3 cfs @ 12.14 hrs, Volume= 4,904 cf Primary = 1.3 cfs @ 12.14 hrs, Volume= 4,904 cf, Atten= 0%, Lag= 0.0 min Primary outflow = Inflow, Time Span= 0.00-48.00 hrs, dt= 0.03 hrs Link DP-1: Hartford Avenue Inflow Primary Hydrograph Time (hours) 484644424038363432302826242220181614121086420 Flow (cfs) 1 0 Inflow Area=12,127 sf 1.3 cfs 1.3 cfs
Page 286
Type III 24-hr 100-Year Rainfall=8.63"251219 - POST Printed 6/1/2026Prepared by R Levesque Associates Page 34HydroCAD® 10.20-8a s/n 02175 © 2025 HydroCAD Software Solutions LLC Summary for Link DP-2: Off-Site Wetlands Inflow Area = 99,066 sf, 23.48% Impervious, Inflow Depth = 1.51" for 100-Year event Inflow = 4.2 cfs @ 12.26 hrs, Volume= 12,490 cf Primary = 4.2 cfs @ 12.26 hrs, Volume= 12,490 cf, Atten= 0%, Lag= 0.0 min Primary outflow = Inflow, Time Span= 0.00-48.00 hrs, dt= 0.03 hrs Link DP-2: Off-Site Wetlands Inflow Primary Hydrograph Time (hours) 484644424038363432302826242220181614121086420 Flow (cfs) 4 3 2 1 0 Inflow Area=99,066 sf 4.2 cfs 4.2 cfs
Page 287
Page 288
Page 289
PCB-1 PCB-2 PYD-1 PYD-2 PYD-3 RF-1 RF-2 RF-3 Routing Diagram for 251219 - INLET Prepared by R Levesque Associates, Printed 5/28/2026 HydroCAD® 10.20-8a s/n 02175 © 2025 HydroCAD Software Solutions LLC Subcat Reach Pond Link
Page 290
Type III 24-hr 10-Year Rainfall=4.86"251219 - INLET Printed 5/28/2026Prepared by R Levesque Associates Page 2HydroCAD® 10.20-8a s/n 02175 © 2025 HydroCAD Software Solutions LLC Summary for Subcatchment PCB-1: Runoff = 0.6 cfs @ 12.13 hrs, Volume= 2,462 cf, Depth= 4.48" Runoff by SCS TR-20 method, UH=SCS, Weighted-Q, Time Span= 0.00-48.00 hrs, dt= 0.03 hrs Type III 24-hr 10-Year Rainfall=4.86" Area (sf) CN Description 292 61 >75% Grass cover, Good, HSG B 2,799 98 Paved parking, HSG A 3,510 98 Paved parking, HSG B 6,601 Weighted Average 292 61 4.42% Pervious Area 6,309 98 95.58% Impervious Area Tc Length Slope Velocity Capacity Description (min) (feet) (ft/ft) (ft/sec) (cfs) 10.0 Direct Entry, Summary for Subcatchment PCB-2: Runoff = 1.1 cfs @ 12.13 hrs, Volume= 4,457 cf, Depth= 4.15" Runoff by SCS TR-20 method, UH=SCS, Weighted-Q, Time Span= 0.00-48.00 hrs, dt= 0.03 hrs Type III 24-hr 10-Year Rainfall=4.86" Area (sf) CN Description 19 39 >75% Grass cover, Good, HSG A 1,613 61 >75% Grass cover, Good, HSG B 6,308 98 Paved parking, HSG A 4,694 98 Paved parking, HSG B 88 98 Roofs, HSG B 154 55 Woods, Good, HSG B 12,876 Weighted Average 1,786 60 13.87% Pervious Area 11,090 98 86.13% Impervious Area Tc Length Slope Velocity Capacity Description (min) (feet) (ft/ft) (ft/sec) (cfs) 10.0 Direct Entry, Summary for Subcatchment PYD-1: Runoff = 0.0 cfs @ 12.16 hrs, Volume= 101 cf, Depth= 1.29" Runoff by SCS TR-20 method, UH=SCS, Weighted-Q, Time Span= 0.00-48.00 hrs, dt= 0.03 hrs Type III 24-hr 10-Year Rainfall=4.86"
Page 291
Type III 24-hr 10-Year Rainfall=4.86"251219 - INLET Printed 5/28/2026Prepared by R Levesque Associates Page 3HydroCAD® 10.20-8a s/n 02175 © 2025 HydroCAD Software Solutions LLC Area (sf) CN Description 938 61 >75% Grass cover, Good, HSG B 2 98 Roofs, HSG B 940 Weighted Average 938 61 99.84% Pervious Area 2 98 0.16% Impervious Area Tc Length Slope Velocity Capacity Description (min) (feet) (ft/ft) (ft/sec) (cfs) 10.0 Direct Entry, Summary for Subcatchment PYD-2: Runoff = 0.1 cfs @ 12.16 hrs, Volume= 210 cf, Depth= 1.16" Runoff by SCS TR-20 method, UH=SCS, Weighted-Q, Time Span= 0.00-48.00 hrs, dt= 0.03 hrs Type III 24-hr 10-Year Rainfall=4.86" Area (sf) CN Description 1,421 61 >75% Grass cover, Good, HSG B 0 98 Roofs, HSG B 757 55 Woods, Good, HSG B 2,178 Weighted Average 2,178 59 99.99% Pervious Area 0 98 0.01% Impervious Area Tc Length Slope Velocity Capacity Description (min) (feet) (ft/ft) (ft/sec) (cfs) 10.0 Direct Entry, Summary for Subcatchment PYD-3: Runoff = 0.1 cfs @ 12.16 hrs, Volume= 220 cf, Depth= 1.29" Runoff by SCS TR-20 method, UH=SCS, Weighted-Q, Time Span= 0.00-48.00 hrs, dt= 0.03 hrs Type III 24-hr 10-Year Rainfall=4.86" Area (sf) CN Description 2,056 61 >75% Grass cover, Good, HSG B 2,056 61 100.00% Pervious Area Tc Length Slope Velocity Capacity Description (min) (feet) (ft/ft) (ft/sec) (cfs) 10.0 Direct Entry,
Page 292
Type III 24-hr 10-Year Rainfall=4.86"251219 - INLET Printed 5/28/2026Prepared by R Levesque Associates Page 4HydroCAD® 10.20-8a s/n 02175 © 2025 HydroCAD Software Solutions LLC Summary for Subcatchment RF-1: Runoff = 0.1 cfs @ 12.13 hrs, Volume= 515 cf, Depth= 4.62" Runoff by SCS TR-20 method, UH=SCS, Weighted-Q, Time Span= 0.00-48.00 hrs, dt= 0.03 hrs Type III 24-hr 10-Year Rainfall=4.86" Area (sf) CN Description 1,336 98 Roofs, HSG B 1,336 98 100.00% Impervious Area Tc Length Slope Velocity Capacity Description (min) (feet) (ft/ft) (ft/sec) (cfs) 10.0 Direct Entry, Summary for Subcatchment RF-2: Runoff = 0.1 cfs @ 12.13 hrs, Volume= 515 cf, Depth= 4.62" Runoff by SCS TR-20 method, UH=SCS, Weighted-Q, Time Span= 0.00-48.00 hrs, dt= 0.03 hrs Type III 24-hr 10-Year Rainfall=4.86" Area (sf) CN Description 0 61 >75% Grass cover, Good, HSG B 1,337 98 Roofs, HSG B 1,337 Weighted Average 0 61 0.02% Pervious Area 1,337 98 99.98% Impervious Area Tc Length Slope Velocity Capacity Description (min) (feet) (ft/ft) (ft/sec) (cfs) 10.0 Direct Entry, Summary for Subcatchment RF-3: Runoff = 0.3 cfs @ 12.13 hrs, Volume= 1,034 cf, Depth= 4.62" Runoff by SCS TR-20 method, UH=SCS, Weighted-Q, Time Span= 0.00-48.00 hrs, dt= 0.03 hrs Type III 24-hr 10-Year Rainfall=4.86" Area (sf) CN Description 2 61 >75% Grass cover, Good, HSG B 2,684 98 Roofs, HSG B 2,685 Weighted Average 2 61 0.07% Pervious Area 2,684 98 99.93% Impervious Area
Page 293
Type III 24-hr 10-Year Rainfall=4.86"251219 - INLET Printed 5/28/2026Prepared by R Levesque Associates Page 5HydroCAD® 10.20-8a s/n 02175 © 2025 HydroCAD Software Solutions LLC Tc Length Slope Velocity Capacity Description (min) (feet) (ft/ft) (ft/sec) (cfs) 10.0 Direct Entry,
Page 294
Page 295
Page 296
Page 297
Page 298
Page 299
7353 SF 25,767 SF 18,414 SF 22,866 SF Total Existing Impervious Area Total Proposed Impervious Area Total New Impervious Area Total Impervious Area Tributary to Recharge Facilities
Page 300
The volume retained in the subsurface infiltration basin below the lowest outlet invert exceeds the required water quality volume. Retaining 100% of the required water quality volume satisfies standard 1 and does not require further calculations for additional pollutan removal.
Page 301
Type III 24-hr 100-Year Rainfall=8.63"251219 - POST Printed 5/28/2026Prepared by R Levesque Associates HydroCAD® 10.20-8a s/n 02175 © 2025 HydroCAD Software Solutions LLC Stage-Area-Storage for Pond 1P: Subsurface Infiltration Basin (continued) Elevation (feet) Surface (sq-ft) Storage (cubic-feet) 196.58 2,011 2,891 196.59 2,011 2,906 196.60 2,011 2,920 196.61 2,011 2,934 196.62 2,011 2,948 196.63 2,011 2,963 196.64 2,011 2,977 196.65 2,011 2,991 196.66 2,011 3,005 196.67 2,011 3,019 196.68 2,011 3,033 196.69 2,011 3,047 196.70 2,011 3,061 196.71 2,011 3,075 196.72 2,011 3,089 196.73 2,011 3,103 196.74 2,011 3,117 196.75 2,011 3,130 196.76 2,011 3,144 196.77 2,011 3,158 196.78 2,011 3,172 196.79 2,011 3,185 196.80 2,011 3,199 196.81 2,011 3,213 196.82 2,011 3,226 196.83 2,011 3,240 196.84 2,011 3,254 196.85 2,011 3,267 196.86 2,011 3,281 196.87 2,011 3,294 196.88 2,011 3,307 196.89 2,011 3,321 196.90 2,011 3,334 196.91 2,011 3,347 196.92 2,011 3,361 196.93 2,011 3,374 196.94 2,011 3,387 196.95 2,011 3,400 196.96 2,011 3,413 196.97 2,011 3,427 196.98 2,011 3,440 196.99 2,011 3,453 197.00 2,011 3,466 197.01 2,011 3,478 197.02 2,011 3,491 197.03 2,011 3,504 197.04 2,011 3,517 197.05 2,011 3,530 197.06 2,011 3,543 197.07 2,011 3,555 197.08 2,011 3,568 197.09 2,011 3,580 Elevation (feet) Surface (sq-ft) Storage (cubic-feet) 197.10 2,011 3,593 197.11 2,011 3,606 197.12 2,011 3,618 197.13 2,011 3,630 197.14 2,011 3,643 197.15 2,011 3,655 197.16 2,011 3,667 197.17 2,011 3,680 197.18 2,011 3,692 197.19 2,011 3,704 197.20 2,011 3,716 197.21 2,011 3,728 197.22 2,011 3,740 197.23 2,011 3,752 197.24 2,011 3,764 197.25 2,011 3,776 197.26 2,011 3,787 197.27 2,011 3,799 197.28 2,011 3,811 197.29 2,011 3,822 197.30 2,011 3,834 197.31 2,011 3,845 197.32 2,011 3,856 197.33 2,011 3,868 197.34 2,011 3,879 197.35 2,011 3,890 197.36 2,011 3,901 197.37 2,011 3,912 197.38 2,011 3,923 197.39 2,011 3,934 197.40 2,011 3,944 197.41 2,011 3,955 197.42 2,011 3,966 197.43 2,011 3,976 197.44 2,011 3,986 197.45 2,011 3,996 197.46 2,011 4,006 197.47 2,011 4,016 197.48 2,011 4,026 197.49 2,011 4,036 197.50 2,011 4,046 197.51 2,011 4,055 197.52 2,011 4,065 197.53 2,011 4,074 197.54 2,011 4,083 197.55 2,011 4,093 197.56 2,011 4,102 197.57 2,011 4,111 197.58 2,011 4,120 197.59 2,011 4,129 197.60 2,011 4,138 197.61 2,011 4,147
Page 302
Page 303
Barracuda® Max The Barracuda Max is market-changing stormwater quality technology. This high-performance vortex hydrodynamic separator is designed to remove total suspended solids in order to protect our precious receiving waters. The Barracuda Max is also an outstanding value that offers multiple pipe configurations, and quick installation. The “Max” version of the Barracuda is built on the base platform of the original ADS Barracuda with improved removal efficiencies and installation components. Features • Single manhole design • No elevation loss between the inlet and outlet • Variable inlet/outlet angle configurations (not just 180 degree orientation) • Internal bypass for inline installation (where applicable) • Revolutionary, patent pending “teeth” mitigate turbulence in the sump area to prevent resuspension of captured contaminants • Available with grated drop inlet configuration • Available with trash and/or oil capture add-ons Benefits • Internal components are in stock for quick delivery • The S3, S4, S6, and S8 can be installed in a standard 36” (900 mm), 48” (1200 m), 72” (1800 m), and 96” (2400 m) precast manhole, respectively • The S3 & S4 can be provided factory installed within a 36” (900 mm) and 48” (1200 mm) ADS HP manhole and delivered to the jobsite • The Barracuda Max “teeth” and deflector plate apparatus are fabricated and designed for quick and easy field assembly • Designed for easy maintenance using a vacuum truck or similar equipment. • Inspection and maintenance are performed from the surface with no confined space entry
Page 304
Barrucuda Specification Materials and Design • Concrete Structures: Designed for H-20 traffic loading and applicable soil loads or as otherwise determined by a Licensed Professional Engineer. The materials and structural design of the devices shall be per ASTM C857 and ASTM C858. • 36” (900 mm) and 48” (1200 mm) HP Manhole Structures: Made from an impact modified copolymer polypropylene meeting the material requirements of ASTM F2764. The eccentric cone reducer shall be manufactured from polyethylene material meeting ASTM D3350 cell class 213320C. Gaskets shall be made of material meeting the requirements of ASTM F477. • Separator internals shall be substantially constructed of stainless steel, polyethylene or other thermoplastic material approved by the manufacturer. Performance • The stormwater treatment unit shall be an inline unit capable of conveying 100% of the design peak flow. If peak flow rates exceed maximum hydraulic rate, the unit shall be installed offline. • The Barracuda Max unit shall be designed to remove at least 80% of the suspended solids on an annual aggregate removal basis. Said removal shall be based on full-scale third party testing using OK-110 media gradation or equivalent and 300 mg/L influent concentration. Said full scale testing shall have included sediment capture based on actual total mass collected by the stormwater treatment unit. - OR - The Barracuda Max unit shall be designed to remove at least 50% of TSS using a media mix with d50=75 micron and 200 mg/L influent concentration. - OR - The Barracuda Max unit shall be designed to remove at least 50% of TSS per current NJDEP/NJCAT HDS protocol. • The stormwater treatment unit internals shall consist of (1) separator cone assembly, and (1) sump assembly, which includes the “teeth”. Installation Installation of the stormwater treatment unit(s) shall be performed per manufacturer’s installation instructions. Such instructions can be obtained by calling Advanced Drainage Systems at 800-821-6710 or by logging on to www.adspipe.com. Barracuda Max Model Manhole Diameter OK-110 (80% removal) Pretreatment for Infiltration1 S3 36” (900 mm) 0.86 CFS (24.1 L/s) 1.65 CFS (46.7 L/s) S4 48” (1200 mm) 1.52 CFS (43.0 L/s) 2.94 CFS (83.3 L/s) S6 72” (1800 mm) 3.42 CFS (96.8 L/s) 6.62 CFS (187.5 L/s) S8 96” (2400 mm) 6.08 CFS (172.2 L/s) 11.76 CFS (333.0 L/s) ADS “Terms and Conditions of Sale” are available on the website, www.ads-pipe.com . The ADS logo, Barracuda logo, and the Green Stripe are registered trademarks of Advanced Drainage Systems, Inc. © 2022 Advanced Drainage Systems, Inc. 4/22 CS adspipe.com 800-821-6710 ADS N-12® ST IB Pipe (per ASTM F2648) * Peak bypass flows are dependent on final design 1 50% removal of OK-110.
Page 305
One of Barracuda’s advantages is the ease of maintenance. Like any system that collects pollutants, the Barracuda must be maintained for continued effectiveness. Maintenance is a simple procedure performed using a vacuum truck or similar equipment. The systems were designed to minimize the volume of water removed during routine maintenance, reducing disposal costs. Contractors can access the pollutants stored in the manhole through the manhole cover. This allows them to gain vacuum hose access to the bottom of the manhole to remove sediment and trash. There is no confined space entry necessary for inspection or maintenance. The entire maintenance procedure typically takes 2 to 4 hours, depending on the system’s size, the captured material, and the vacuum truck’s capacity. Local regulations may apply to the maintenance procedure. Safe and legal disposal of pollutants is the responsibility of the maintenance contractor. Maintenance should be performed only by a qualified contractor. Inspection and Cleaning Cycle Periodic inspection is needed to determine the need for and frequency of maintenance. You should begin inspecting as soon as construction is complete and then on an annual basis. Typically, the system needs to be cleaned every 1-3 years. Excessive oils, fuels or sediments may reduce the maintenance cycle. Periodic inspection is important. Determining When to Clean To determine the sediment depth, the maintenance contractor should lower a stadia rod into the manhole until it contacts the top of the captured sediment and mark that spot on the rod. Then push the probe through to the bottom of the sump and mark that spot to determine sediment depth. Maintenance should occur when the sediment has reached the levels indicated in the Storage Capacity Chart. adspipe.com 1-800-821-6710
Page 306
Barracuda Storage Capacities Model Manhole Diameter in. (mm) Total System Volume Gallons (Liters) Treatment Chamber Capacity Gallons (Liters) Standard Sediment Capacity (20” depth) Yards3 (meters3) NJDEP Sediment Capacity (50% of standard depth) Yards3 (meters3) S3 36 (900) 264 (999) 212 (803) 0.44 (0.34) 0.22 (0.17) S4 48 (1200) 665 (2517) 564 (2135) 0.78 (0.60) 0.39 (0.30) S6 72 (1800) 1497 (5667) 1269 (4804) 1.75 (1.34) 0.88 (0.67) S8 96 (2400) 4196 (15884) 3835 (14517) 3.10 (2.37) 1.55 (1.19) Maintenance Instructions 1. Remove the manhole cover to provide access to the pollutant storage. Pollutants are stored in the sump, below the bowl assembly visible from the surface. Access this area through the 8” (200 mm), 10” (250 mm), 15” (375 mm) or 20” (500 mm) diameter access cylinder. 2. Use a vacuum truck or other similar equipment to remove all water, debris, oils and sediment. See figure 1. 3. Use a high pressure hose to clean the manhole of all the remaining sediment and debris. Then, use the vacuum truck to remove the water. 4. Fill the cleaned manhole with water until the level reaches the invert of the outlet pipe. 5. Replace the manhole cover. 6. Dispose of the polluted water, oils, sediment and trash at an approved facility. a. Local regulations prohibit the discharge of solid material into the sanitary system. Check with the local sewer authority for authority to discharge the liquid. b. Some localities treat the pollutants as leachate. Check with local regulators about disposal requirements. c. Additional local regulations may apply to the maintenance procedure. adspipe.com 1-800-821-6710 Figure 1 ADS “Terms and Conditions of Sale” are available on the ADS website, www.ads-pipe.com The ADS logo, Barracuda® and the Green Stripe are registered trademarks of Advanced Drainage Systems, Inc. © 2022 Advanced Drainage Systems, Inc. MG1.01 08/22 CS
Page 307
Page 308
Page 309
Page 310
Page 311
Page 312
Page 313
Page 314
Page 315
Page 316
Page 317
Page 318
Page 319
Page 320
Page 321
Page 322
Page 323
Page 324
Page 325
Page 326
Page 327
Page 328
Page 329
Page 330
Page 331
A. Provide low-maintenance, native vegetation that encourages water retention and minimizes the use of lawns, fertilizers, and pesticides. B. Minimize new impervious surfaces. C. Match as closely as possible the pre-development or natural site runoff characteristics in terms of volume and timing of runoff (mimic the natural water cycle).
Page 332
A. Break up or disconnect the flow of runoff from impervious surfaces by directing it to adjacent pervious, vegetated surfaces (disconnect). B. Infiltrate precipitation as close as possible to the point it reaches the ground using multiple, small-scale structural stormwater BMPs distributed throughout a site (decentralize and distribute). C. Utilize less complex, non-structural methods for stormwater management that are lower cost and lower maintenance than conventional structural controls. D. Provide source controls to prevent or minimize the use or exposure of pollutants into stormwater runoff at the site in order to prevent or minimize the release of those pollutants into stormwater runoff.
Page 333
Kevin Clark, PEL Town Engineer Town of Granby 15 North Granby Road Granby, CT 06035 CT: (860) 844-5318 E-MAIL: townengineer@granby-ct.gov Page 1 of 2 Plan Review June 15, 2026 “Site Plans, Residential Development, 37 Hartford Avenue – Granby, CT 06035, Mr. Forest Dvine, 129 Lovers Lane, Granville, MA 01034, by R Levesque Associates, Inc., Francis Real Estate Holdings, Scale: 1”=30’, Date: May 27, 2026.” Comments: EX-1: 1. There is a monument uphill of the existing farm road, west of the 12” VC. Please show on plan. 2. The existing 12” VC pipe appears to be in good condition at the outlet. There is evidence of water flow, but the area downstream of the outlet is stable with no evidence of erosion. Outlet stabilization is not required. 3. Per A-2 Standards, all property corners shall be noted as found or set. C-1: 4. “Non-structural Control Practices.” Note that silt fences shall not be used where there is an existing/ proposed direct flow of water. 5. “Structural Control Practices”: Is rip-rap outlet protection proposed at all outlets? See note 2. 6. “Silt Fence Installation Notes:” Modify notes to reflect comment #1. 7. “Hay Bale Installation & Maintenance:” Hay Bales are not specified or shown on the drawings. 8. “Site Prep:” Note 6, include no burying of demolished materials. 9. Add a project narrative as per page 44, Chapter 3 of Connecticut Guidelines for Soil Erosion and Sediment Control. Add the responsible party. C-2: 10. There are no sanitary sewers included in the project as the property will be served by an on -site septic system.. All septic system specifications shall refer to CTDPH Technical Standards. 11. There are no water mains proposed. All water service specifications shall refer to Salmon Brook Water District Standards. 12. Add “Stormwater Management System.” Include material specifications for all components of the system. Note that stormwater pipe (HDPE) shall have a smooth interior (CPEP-S). C-4: 13. Coordinate with CTDOT regarding the location of the proposed sidewalk along RT 189. 14. Suggest removing all items noted as being demolished from the sheets showing proposed features to reduce confusion. C-5: 15. At back entrance to building. Contour 201 next to the door with FFE=200.5? 16. Revise the grading in the parking lot so that the maximum surface grade is 5%.
Page 334
Kevin Clark, PEL Town Engineer Town of Granby 15 North Granby Road Granby, CT 06035 CT: (860) 844-5318 E-MAIL: townengineer@granby-ct.gov Page 2 of 2 17. Revise grading where the entrance drive meets the parking lot. The current grading shows the driveway at 7% then a 10% slope turning into the lot, then a parking surface at 5.5%. This could be an awkward transition. 18. Add some spot grades at the front entrance steps/ramp to the building. 19. Show location of any septic system access ports and or manholes. C-6: 20. Add a cleanout in roof collector system where the system tees into the detention/infiltration system. 21. Show the location and profiles for the soil tests used to size the leaching system. Stormwater Drainage Report: 22. Note in report that 8.27 in/hr. is a “Rawls Rate,” and is used for modeling the exfiltration rate from the infiltration system. Include a Rawls Rate table in the report and how the measured infiltration rates justify its use. 23. Add Long Term Stormwater Maintenance Program and the O & M Inspection Checklist table on page 197 to one of the site plan sheets. This is what the contractor, owner, and the Town will refer to during and after construction. 24. Make sure that the site plans are coordinated with the Construction Period Erosion Control Plan. 25. Table 3.1 shows that the post-development peak discharge rates will be equal to or less than the pre-development rates. 26. The proposed improvements appear to comply with the CTDEEP Stormwater Management Standards. by: Kevin Clark, PEL, Town Engineer
Page 335
TOWN OF GRANBY 15 North Granby Road Granby, Connecticut 06035-2102 860-844-5318 TO: Granby Inland Wetlands and Watercourses Commission FROM: Kate Bednaz, Inland Wetlands and Watercourses Agent Date: June 26, 2026 Subject: 37 Hartford Avenue – Forrest Devine– Site Re-Development – Agent Review Documents have been submitted for review by the Granby Inland Wetlands and Watercourses Agency (Granby IWWC) to date by the applicant, Forest Devine and their representative R Levesque Associates, Inc. has submitted as part of the application the plan set entitled “Site Plans, Residential Development, 37 Hartford Avenue – Granby, CT 06035, Mr. Forest Devine, 129 Lovers Lane, Granville, MA 01034, by R Levesque Associates, Inc. Francis Real Estate Holdings, dated May 27, 2026”. The following comments are a result of a field review on June 11, 2026, and the review of all application materials submitted to date. Additional review and comments will be required upon receipt of revised plans and additional information. A. Please address all comments issued by the Granby Town Engineer in his June 15, 2026, plan review memo. B. Please note that a groundwater seep was observed during a 2023 field review at wetland flag A20/21, approximately at elevation 169 -170. Conditions were not observable during this years site visit. C. The watercourse at the base of the slope is a perennial tributary to the Salmon Brook. D. Please note that the Natural Diversity Database was consulted regarding th e previous site application and found that critical species/habitat were identified for protection. It is strongly recommended that a similar consultation with NDDB be conducted for the proposed project. E. It is recommended that additional long standing mitigation be considered as part of the site development efforts. This may include but not be limited to the following considerations. a. Removal of all invasive species on the project site. The plan for removal shall be outlined in an invasive species treatment plan located within the project plan set. It is recommended that the treatment be conducted in conjunction with any mitigation plantings. The Granby IWWC shall be notified in writing when the invasive species removal activities are complete. No invasive species shall be present on the property at the time of project completion. This shall be a requirement of the bond release. b. Installation of woody plantings or like, on the top of the slope, adjacent to the rear of the parking area . The intent would be to aid in preventing windblown parking lot debris from migrating beyond the wood line, as an aid towards long-term diverse
Page 336
37 Hartford Avenue – Agent Review Page 2 of 2 native species slope stabilization, enhancement of species diversity and wildlife habitat adjacent to the NDDB listed critical species and their associated habitat. c. Any mitigation plantings installed shall be required to remain viable through 2 full growing seasons, starting at the date of installation. d. The selective planting of native trees on the previously disturbed slope within 50 feet from the wetland boundary. This will provide canopy cover adjacent to the wetland to reduce solar exposure, prevent the re-establishment of invasive species, and prevent human debris from the parking area from blowing into the wetland at the base of the slope. Plantings may be installed in a manner to preserve the existing farm road. It does not appear that many additional trees will be required considering the increased vegetative density. Canopy plantings are recommended in the “holes” where invasive large shrubs persisted or no canopy is currently established. e. Consider installing cover ed solar parking along the row of parking area long the slope to reduce solar radiation and offset operation costs. Utilizing light -colored concrete may also be a consideration. f. While pervious pavement is always a consideration, the sub surface infiltration units will essentially accomplish a like benefit. F. The clay pipe outfall location was observed in the field to be open to allow for stormwater flow. However, the end has been broken and has over time receded where there is some minor erosion. The applicant investigated the remainder of the pipe, downgradient of their connection point and found there to be no obstructions to flow within the existing pipe. If the project and town engineer agree that flow volumes and velocities will not change in this location, then I recommend the outfall stay in its current condition. The outfall shows no sign of active erosion; it appears to have reached a sustainable channel to accommodate the current flow. G. It is understood that the septic system design is currently under review by the FVHD. Please demonstrate to the IWWC that the system will meet the minimum design requirements as it relates to the potential for the leaching of nutrients, as it relates to their potential to discharge these nutrients to the downgradient resource areas and critical NDDB habitat. H. Snow storage. Please detail on the project plans and the O&M Plan for the facility how snow will be handled. Can extra storage area be designated? Will snow be hauled off site if the storage area overflows? How will salt and sanding be conducted as it rela tes to protecting the adjacent resources? a. It is recommended that “NO SNOW STORAGE” signs be installed along the entire top of slope, along the back of the parking area to prevent snow storage from expanding outside of the designated area. In addition, the “SNOW STORAGE AREA” should be clearly marked as well. It is recommended that the signs be different colors, for example red and green, to provide clear communication. I. IWWC application fees may need to be adjusted if the impervious area is modified to include more area with the URA or direct impacts to wetlands. If no, or less changes are to occur, the filing fee is correct.
Page 337
Outlook 37 Hartford Ave, Granby, CT - Drainage Overflow Connection From Rebecca Li <RebeccaL@rlaland.com> Date Fri 6/12/2026 9:48 AM To Abigail Kenyon <akenyon@granby-ct.gov>; Granby Wetlands Agent <wetlandsagent@granby-ct.gov> Cc Renee Deltenre <RDeltenre@granby-ct.gov>; Nina Fazio <NinaF@rlaland.com>; Forrest Devine <forrestdevine7@gmail.com>; Rob Levesque <RobL@rlaland.com> 1 attachment (1 MB) Email from CTDOT on Drainage Connection (06-09-26).pdf; CAUTION: This email originated from outside of the organization. Do not click links or open attachments unless you recognize the sender and know the content is safe. Good morning, Abby & Kate, I briefly mentioned at the meeting on Wednesday night that we received correspondence from CTDOT that they wouldn’t be opposed to us connecting our drainage overflow into the existing drain line that cuts through our property as long as it doesn’t adversely impact their system. Attached is the email correspondence. Additionally, we also had the pipelines scoped and I have included the CCTV footage in the onedrive link below: CCTV Inspection on Existing CTDOT Drain Line Kind regards, Rebecca Li, P.E. Project Engineer RebeccaL@rlaland.com R Levesque Associates, Inc. 40 School Street P.O. Box 640 Westfield, MA 01085 Direct 413.729.6892 Office 413.568.0985 (x112) Fax 413.568.0986 This email may contain confidential and/or privileged information. If you are not the intended recipient, you are hereby notified that retention, dissemination, or copying of this communication is prohibited. If you have received this email in error, please notify the sender by reply email and permanently delete this email and any attachments. Thank you.
Page 338
1 Rebecca Li From: Case, Kyle C <Kyle.Case@ct.gov> Sent: Tuesday, June 9, 2026 7:18 AM To: Rebecca Li Cc: Mancini, Joseph; Forrest Devine; Steeves, Aron J; Nemecek, Judith A Subject: RE: Preliminary Coordination Request – Overflow Connection to Existing CTDOT Drainage Infrastructure at 37 Hartford Avenue, Granby, CT Hi Rebecca, The CTDOT would consider allowing a connection to our drainage if it is shown that our system would not be adversely impacted by the connection. This would be determined during the encroachment permit application stage with supporting documentation. Please let me know if you need anything else or have any other questions. Thank you, Kyle KYLE CASE, P.E. Transportation Engineer III Connecticut Department of Transportation District 4 Special Services Phone: 203-591-3629 kyle.case@ct.gov From: Nemecek, Judith A <Judith.Nemecek@ct.gov> Sent: Monday, June 8, 2026 7:13 PM To: Rebecca Li <RebeccaL@rlaland.com>; Case, Kyle C <Kyle.Case@ct.gov> Cc: Mancini, Joseph <Joseph.Mancini@ct.gov>; Forrest Devine <forrestdevine7@gmail.com>; Steeves, Aron J <Aron.Steeves@ct.gov> Subject: RE: Preliminary Coordination Request – Overflow Connection to Existing CTDOT Drainage Infrastructure at 37 Hartford Avenue, Granby, CT Hi Kyle, would you be able to review this request? Judith A. Nemecek, P.E. District Engineer Connecticut Department of Transportation District 4 | 359 South Main Street | Thomaston, CT 06787 203.591.3544 (O) | 203.851.2755 (C) judith.nemecek@ct.gov
Page 339
2 From: Rebecca Li <RebeccaL@rlaland.com> Sent: Monday, June 8, 2026 4:18 PM To: Nemecek, Judith A <Judith.Nemecek@ct.gov> Cc: Mancini, Joseph <Joseph.Mancini@ct.gov>; Forrest Devine <forrestdevine7@gmail.com> Subject: Preliminary Coordination Request – Overflow Connection to Existing CTDOT Drainage Infrastructure at 37 Hartford Avenue, Granby, CT EXTERNAL EMAIL: This email originated from outside of the organization. Do not click any links or open any attachments unless you trust the sender and know the content is safe. Hello Judith, I am one of the project engineers working on a development project at 37 Hartford Avenue in Granby, CT. I am reaching out regarding the feasibility of connecting an overflow discharge from our proposed stormwater management system to an existing drainage line on the subject property that is within CTDOT jurisdiction. The existing drainage line provides an outlet for the drainage system within Hartford Avenue to the wetlands located on the south side of the project site (see highlighted drain line on the attached plan). We would like to request CTDOT's consideration of a connection to this existing line to serve as an emergency overflow from a proposed subsurface infiltration basin. The proposed connection would have a minimal impact on the existing drainage system. No stormwater discharge would occur through the overflow structure until the 10-year, 24-hour storm event. The estimated peak overflow discharge rates are as follows: 10-year, 24-hour storm: 0.7 cfs 100-year, 24-hour storm: 2.7 cfs We understand that a formal CTDOT permit application cannot be submitted until local approvals have been obtained. However, the local permitting authorities have requested that we assess the likelihood of obtaining CTDOT approval for the proposed overflow connection as part of their review process. To further evaluate the feasibility of the connection, we intend to perform a CCTV inspection of the existing drainage line to assess its condition. We would also welcome the opportunity to meet with a CTDOT representative on site to discuss the proposal and review any concerns. Additionally, the developer is willing to consider reasonable improvements or modifications to the existing drainage infrastructure if deemed necessary to facilitate the connection and enhance the overall condition of the system. We appreciate your time and consideration and would welcome any preliminary feedback regarding the feasibility of this proposal. Kind regards,
Page 340
3
Page 341
Outlook FW: SUBMISSION - 37 Hartford Avenue (Devine) - Septic Design Plan From Abigail Kenyon <akenyon@granby-ct.gov> Date Fri 6/12/2026 10:06 AM To Renee Deltenre <RDeltenre@granby-ct.gov> FYI From: Rebecca Li <RebeccaL@rlaland.com> Sent: Friday, June 12, 2026 9:51 AM To: Granby Wetlands Agent <wetlandsagent@granby-ct.gov>; Abigail Kenyon <akenyon@granby-ct.gov> Cc: Nina Fazio <NinaF@rlaland.com>; Forrest Devine <forrestdevine7@gmail.com>; Rob Levesque <RobL@rlaland.com>; Kevin Clark <townengineer@granby-ct.gov> Subject: FW: SUBMISSION - 37 Hartford Avenue (Devine) - Septic Design Plan CAUTION: This email originated from outside of the organization. Do not click links or open attachments unless you recognize the sender and know the content is safe. Hello, Just wanted to share with you that we submitted the septic application to the Farmington Valley Health District. We will keep you posted as new developments occur. Kind regards, Rebecca Li, P.E. Project Engineer RebeccaL@rlaland.com R Levesque Associates, Inc. 40 School Street P.O. Box 640 Westfield, MA 01085 Direct 413.729.6892 Office 413.568.0985 (x112) Fax 413.568.0986 This email may contain confidential and/or privileged information. If you are not the intended recipient, you are hereby notified that retention, dissemination, or copying of this communication is prohibited. If you have received this email in error, please notify the sender by reply email and permanently delete this email and any attachments. Thank you. From: Nina Fazio <NinaF@rlaland.com> Sent: Friday, June 12, 2026 9:47 AM To: kkula@fvhd.org Cc: Rob Levesque <RobL@rlaland.com>; Rebecca Li <RebeccaL@rlaland.com>; Jeanne Cook <jeannec@rlaland.com>; Forrest Devine <forrestdevine7@gmail.com> Subject: SUBMISSION - 37 Hartford Avenue (Devine) - Septic Design Plan Good morning, Kristin,
Page 342
Please accept this electronic submission of a septic design plan and supporting documentation. Jeanne from our office will be dropping off some hard copies and the filing fee check. Is there a certain time that works best for you? 2026-06-12 - Septic If you have any comments or questions during your review, please do not hesitate to reach out to our office. Thank you in advance for your time! Enjoy your weekend, Nina Fazio Permitting Coordinator R Levesque Associates, Inc. rlaland.com 40 School Street P.O. Box 640 Westfield, MA 01085 Direct 413.729.6894 Office 413.568.0985 This email may contain confidential and/or privileged information. If you are not the intended recipient, you are hereby notified that retention, dissemination, or copying of this communication is prohibited. If you have received this email in error, please notify the sender by reply email and permanently delete this email and any attachments. Thank you.
Page 343
Page 1 of 2 TOWN OF GRANBY Incorporated 1786 15 North Granby Road Granby, Connecticut 06035-2102 860-844-5318 July 2, 2026 Certified Mailing #9489 0090 0027 6649 9928 18 Mr. Ross Weiner & Ms. Colleen Fontaine 7 Laurel Drive Granby, CT 06035 Re: Enforcement Order: 7 Laurel Drive, Granby, CT (Mblu: G-51/48/23) Conducting a Regulated Activity without a valid IWWC Permit Dear Mr. Weiner & Ms. Fontaine, The Town of Granby noticed during an inspection of the adjacent property that activities had been completed without a valid Inland Wetlands and Watercourses Commission (IWWC) permit on your property. These activities are in violation of the most recently revised Inland Wetland and Watercourse Regulations. The property contains a single-family house and associated features. Thank you for accompanying me on a site visit of your property on June 5, 2026 where these activities and future intended activities were discussed. An Enforcement Order (EO) was issued to the previous owners on May 21, 2025 for direct disturbance of the wetland resource areas on the property, as delineated during the EO process. Mitigation measures were presented and approved as part of that process. It was understood that the requirement for maintaining the mitigation planting survivability during your ownership and the active EO status information was conveyed during the sale of the property. A show cause hearing for this EO will be held at the IWWC July 8, 2026 public meeting in the Granby Town Hall meeting room at 7pm, your presence is requested. At that time, you may show why there is not cause for the EO, and the IWWC will determine if the EO should be upheld, modified, or removed. The regulated activities that were conducted on the property without a valid permit/determination consist of the following: 1. Wetland area has been filled within the stormwater flow path that consists of stone, shed building, and drainage pipe. The shed has been placed in the middle of a stormwater flow path/regulated wetland that was purposely preserved as part of the last EO/Permit review process. No erosion controls have been installed between the wetland resource area and the work area. 2. A small catch basin and associated drainpipes have been installed within the wetland area, to drain the wetland between the roadway and channel behind the shed. In accordance with the Town of Granby Inland Wetland and Watercourses Regulations, the work that occurred is considered a regulated activity as defined in said regulations and requires a permit application be filed and an approval letter to be issued before commencing such activities in accordance with Section 6 of the regulations. These regulations can be viewed at the Granby Town Hall in the Office of Community Development or online at: https://www.granby-ct.gov/sites/g/files/vyhlif3171/f/uploads/iwwc.regulationsfinal.07-11-18.pdf.
Page 344
Page 2 of 2 The following actions are required to be completed for this EO to be withdrawn. 1. All work within the regulated area or URA on the property shall cease apart from the following: a. Install and maintain the erosion control barrier so that no sediment may leave the disturbance area. This shall include any discharge from any drainage pipes currently installed without a valid permit. b. A written mitigation plan for the restoration of the soil conditions shall be submitted for review and approval by the IWWC at their August 12, 2026 public meeting at 7pm in the Town Hall meeting room. Upon approval of a mitigation plan, all unpermitted impacts shall be removed, and the wetland area restored to its original condition or improved. This includes the removal of the shed, drainage, and any associated features. c. Exposed soil shall be stabilized and seeded with a quick germinating seed mixture, mulch and other soil stabilizing methods shall be implemented to prevent the migration of soil/sediment into the resource areas. Stabilization shall be considered successful when 70% of the area is established with 90% permanent vegetative cover. d. Ensure the adequate closure of the EO that was inherited from the previous owners. A final inspection of the number and survivability of the plantings can be completed at this time upon request to release the existing EO from the property. Please note that in general, any modifications or alterations that require soil disturbance or removal of native vegetation from your property will require review by the IWWC prior to the activity being completed; as your entire property contains wetland resource areas or their associated upland review area, which is 100-feet from a wetland and 200-feet from a watercourse. The record of your property’s wetland conditions were clearly established before your purchase of the property. If you intend to keep the shed and drainage on your property, the IWWC regulations require a permit application with the IWWC to be submitted for their review and approval. Mitigation measures for any impacts will be required. As discussed during my visit to your property, other soil or vegetation disturbance activities were brought up to be completed, please also include these in your application. As always, please contact the Granby Office of Community Development or me at wetlandsagent@granby-ct.gov with any questions or comments. Sincerely, Kate Bednaz Authorized Wetlands Agent Town of Granby, CT
Page 345
Page 346
Page 347
Page 348
Page 349
Page 350
Page 351
Page 352
Page 353
Page 354
Page 355
± 22'-0" APPROXIMATE EXISTING CLEAN-OUT 25'-0" MIN. AREA BUILDING WITH FOOTING DRAIN10'-0" MIN. AREA BUILDING WITH NO FOOTING DRAIN ± 12'-0 26'-0" 11'-6" EXISTING 2 STORY HOUSE WITH FULL FOUNDATION PARTIAL SITE PLAN SCALE: 1/16"=1'-0" 1 L1.1 EXISTING GARAGE UNEXCAVATED EXISTING 1 STORY HOUSE ON PIERS EXISTING DECK PROPOSED 1 STORY HOUSE ON PIERS 50' FRONT YARD SET BACK 25' SIDE YARD SET BACK 25' SIDE YARD SET BACK20'-0" DRAINAGE RIGHT OF WAY 10'-0" 10'-0"PROPERTY LINE EXISTING 1 STORY SHED PROPERTY LINE DAY STREET 138 DAY STREET SITE PLAN SCALE: NTS 2 L1.1 ALTERATION & ADDITION TO ARCHITECTS LLC 41 C NEW LONDON TURNPIKE, GLASTONBURY, CT 06033 DRAWINGS ARENOT TO BE SCALED DATE: 6.5.26 RELEASE: FOR PERMIT CONSTRUCTION DOCUMENTS PROJECT #26109 DALECKI & MAIER RESIDENCE 138 DAY STREETGRANBY, CONNECTICUT PROPOSED SITE PLAN L1.1 PROJECT NORTH NOTES: #1 - DIMENSIONS THAT ARE (±) ARE DIMENSIONS THAT REQUIRE FIELD VERIFICATION,ADJUST AS REQUIRED. DIMENSIONS WITHOUT A (±) ARE TO BE HELD. #2 - TOP OF EXISTING FIRST FLOOR, SUB FLOOR ASSUMED ELEVATION 0'-0". #3 - PLAN WAS DERIVED FROM DIGITAL SCANNING TECHNOLOGY. GENERAL CONTRACTOR TO FIELD VERIFY ALL EXISTING CONDITIONS AND REPORT ANY FINDINGS/DISCREPANCIES TO ARCHITECT PRIOR TO CONSTRUCTION START.
Page 356
UP W. D. EXISTING WATER HEATER EXISTING BOILER EXISTING OIL TANK EXISTING WATER PURIFIER EXISTING CHIMNEY UNFINISHED BASEMENT (ALL AREAS NOT DOCUMENTED) EXISTING SOIL LINE CLEAN-OUT EXISTING HATCHWAY (NOT DOCUMENTED) EXISTING ELECTRICAL PANEL EXISTING SUB-ELECTRICAL PANEL SINK PROPOSED FOUNDATION PLAN SCALE: 1/4"=1'-0" 1 A1.0 ± 22'-0" APPROXIMATE EXISTING CLEAN-OUT 3 A3.1 25'-0" MIN. AREA BUILDING WITH FOOTING DRAIN 10'-0" MIN. AREA BUILIDNG WITH NO FOOTING DRAIN EXISTING AREA WITH NEWER FOUNDATION DRAIN & TRAP ROCK BELOW GRADE. ± 12'-0" EXISTING STRUCTURE ABOVE EXISTING CONDENSER UNIT TO BE RELOCATED PER CODE AND COORDINATE WITH OWNER EXTEND DRYER VENT TO NEW EXTERIOR WALL ABOVE WITH 2X4 FLOOR JOISTS @ 16" O.C. W/ R-15 BATT INSULATION (FOR ADDITIONAL INSULATION) 2X10 FLOOR JOISTS @ 16" O.C. W/ R-30 BATT INSULATION MIN. (MAIN STRUCTURE) 11'-914" 12'-0" 11'-6" 234" 2'-0" P.T. 6X6 POST WITH SIMPSON STRONG-TIE CONNECTORS; BC6 POST CAP WITH (12) 0.162 X 3-1/2 FASTENERS TO EACH BEAM AND POST FLANGES ABU66Z ADJUSTABLE POST BASE WITH 58" DIA. ANCHOR AND (12) 0.162 X 3-1/2 FASTENERS TO POST FLANGE DASHED LINE OF EXTENT OF NEW STRUCTURE ABOVE (3) 1 34" X 9 14" LVL BEAM (3) 1 34" X 9 14" LVL BEAM 10" DIA. CONCRETE PIER ON 3'-0"X3'-0"X1'-6" CONCRETE FOOTING WITH (4) #5 REBAR EACH WAY OR BIGFOOT MODEL BF28 AT 8560 LBS - TYP. (3) ± 15'-1014" CL CL CL 26'-0" 234" CL SIT NEW JOISTS ON EXISTING BALCONY JOISTS - MODIFY AS REQUIRED EXISTING APPLIANCES TO REMAIN (2) P.T. 6X6 HORIZ. POSTS BELOW GRADE AND (2) ABOVE GRADE (NOT SHOWN) AROUND PERIMETER - SEE 3/A3.1 BUILT-UP 4X4 POSTS EACH SIDE UNDER POSTS ABOVE - TYP OF (2) 4 A3.1 EXTEND EXISTING DRYER VENT - PAINTED (SEE ELEVATION) EXTEND EXISTING SPIGOT (SEE ELEVATION) ALTERATION & ADDITION TO ARCHITECTS LLC 41 C NEW LONDON TURNPIKE, GLASTONBURY, CT 06033 DRAWINGS ARENOT TO BE SCALED DATE: 6.5.26 RELEASE: FOR PERMIT CONSTRUCTION DOCUMENTS PROJECT #26109 DALECKI & MAIER RESIDENCE 138 DAY STREETGRANBY, CONNECTICUT PROPOSED FOUNDATION PLAN A1.0 PROJECT NORTH NOTES: #1 - DIMENSIONS THAT ARE (±) ARE DIMENSIONS THAT REQUIRE FIELD VERIFICATION,ADJUST AS REQUIRED. DIMENSIONS WITHOUT A (±) ARE TO BE HELD. #2 - TOP OF EXISTING FIRST FLOOR, SUB FLOOR ASSUMED ELEVATION 0'-0". #3 - PLAN WAS DERIVED FROM DIGITAL SCANNING TECHNOLOGY. GENERAL CONTRACTOR TO FIELD VERIFY ALL EXISTING CONDITIONS AND REPORT ANY FINDINGS/DISCREPANCIES TO ARCHITECT PRIOR TO CONSTRUCTION START.
Page 357
DN UP GARAGE (NOT DOCUMENTED) ART STUDIO LVP VAULTED CEILING FAMILY ROOM CARPET TO LVP VAULTED CEILING DINING ROOM CARPET TO LVP HALL WOOD W.I.C. WOOD BATH (RENO.) PRIME BEDROOM CARPET FOYER WOOD OFFICE WOOD COVERED PORCH (NOT DOCUMENTED) W.C.2'-6" VANITY S & R DBL. OVENS W. D. 5'-0"X 1'-3" DEEP CAB. DWFARMHOUSE SINK W/ BACKSPLASH 46" IN-LINE REFRIG 36" COOKTOP W/ MAX. 400 CFM VENTED HOOD GARAGE TRASH COUNTER MICRO SHELVES SHELVES 36"X36" FOLDING TABLE BY OWNER 36" X 80" C.O. 26'-0" 11'-6" KITCHEN NEW LVP VAULTED CEILING P. RM. NEW TILE LAUNDRY NEW LVP NEW (2) 1 34" X 9 14" LVL FLUSH BEAM W/ BUILT-UP 4X4 POSTS EACH SIDE 30" C.O. PROPOSED FIRST FLOOR PLAN SCALE: 1/4"=1'-0" 1 A1.1 FLAT CEILING SHELVES 10'-0" X 1'-2" BOOK SHELVES REPLACENEW 2'-6" VANITY HANGING ROD DEEP SOAKING SINK IN 29" WIDE CAB. MAKE-UP DESK BY OWNER 2X6 WALL 2X6 WALL 3 A3.1 VACUUM CAB. W/ TOE-KICK ATTACHED TO DOORS (4) 6X6 FAUX BEAMS DECK (NOT DOCUMENTED) A1.1 A 4'-11" 13'-034" 8'-014" CL CL EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTINGEXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING CASED OPG. EXISTING EXISTING CASED OPG. 512" 512" 512" OPEN ON BOTH SIDES 1'-0" 4'-0" 1'-0" 3'-0"1'-0" COORDINATE WITH OWNER LOCATIONS OF DOUBLE HIGH HANGING B A ADJUST WINDOW HEIGHT UPON FINAL SINK W/ BACKSPLASH SELECTION ALIGN FINISH WALLS PATCH ALL WALLS AND CEILINGS TO MATCH AND ALIGN WITH EXISTING MODIFY EXISTING DOOR FOR NEW C.O. TRIM 2'-6" 2'-4" 2'-4" 2'-6" ALIGN FINISH WALLS ART DISPLAY WALL EQUAL EQUAL INFILL WINDOW INFILL WINDOW INFILL WINDOW S & R S & R S & R PROVIDE WASHER DRIP PAN INFILL PARTIAL WINDOW EACH SIDE MODIFY BASEBOARD HEAT AS REQUIRED 2'-6" X 1"-6" CABINET 2'-6" X 1"-6" CABINET 2'-6" X 1"-6" CABINET 3'-0" X 1"-6" CABINET 5'-1"2'-412"312" 512" 312"5'-1"312" NEW (3) 2X10 HEADER BUILT-UP 6X6 POSTS EACH SIDE NEW (2) 2X8 HEADER BUILT-UP 6X6 POSTS EACH SIDE INTERIOR DOORS - 6 PANEL PAINTED TO MATCH EXISTING & HARDWARE - TYP. (4) FAUX BEAM LOCATIONS; NORTH & SOUTH - FLUSH TO WALL MID NORTH - ALIGN WITH EXISTING BATH/HALL WALL MID SOUTH - MIRROR ON CL ON WINDOW EXISTING EXISTING EXISTING EXISTING TILE 4 A3.1 3'-0" 1'-812" 2'-6" ANGLED CEILING CUT BEAMS (DUE TO SECTION) OPTIONAL FLOATING SHELVES INTERIOR KITCHEN ELEVATION 'A' SCALE: 1/4"=1'-0" 2 A1.1 7'-914" 1X VERT. TRIM BETWEEN FAUX BEAMS TILE BACKSPLASH QUARTZ COUNTERTOP PAINTED CABINETS ADJUST WINDOW HEIGHT UPON FINAL SINK W/ BACKSPLASH SELECTION PROPOSED FIRST FLOOR DEMOLITION PLAN SCALE: 1/4"=1'-0" 0 A1.1 KITCHEN REMOVE ENGINEERED WOOD BATH TILE FAMILY ROOM CARPET VAULTED CEILING DINING ROOM CARPET HALL WOOD W.I.C. WOOD FOYER WOOD OFFICE WOOD BALCONY COVERED PORCH (NOT DOCUMENTED) REMOVE BAY WINDOW MODIFY BASEBOARD RADIATOR REMOVE WINDOW EXISTING EXHAUST FAN TO REMAIN - EXTEND VENT TO NEW EXTERIOR WALL REMOVE W.C. REMOVE PEDESTAL SINK NO WORKNO WORK NO WORK NO WORK CARPETENG. WOOD REMOVE BALCONY RAILING REMOVE WINDOW REMOVE DOOR REMOVE CABINETS, COUNTER, APPLIANCES, PLUMBING FIXTURES, FLOORING AND GWB CEILING. COORDINATE WITH OWNER TO SALVAGE ANY ITEMS PRIOR TO DEMO START REMOVE WALLS & CABINETS EXISTING EXISTING EXISTING EXISTING EXISTING EXISTINGDN EXISTING CASED OPG. PROVIDE ALTERNATE ESTIMATE REMOVE EXISTING FAMILY ROOM & DINING ROOM CARPET AND REPLACE WITH LVP REMOVE PARTIAL EXTERIOR WALL - PROVIDE SHORING AS REQUIRED UNTIL NEW BEAM IS INSTALLED REMOVE WINDOW EXISTING EXISTING EXISTING = NEW WOOD WALLS = EXISTING WOOD WALLS = WALLS TO BE REMOVED WALL SCHEDULE WINDOW SCHEDULE ROUGH OPENING 6'-0 3/8" X 3'-0 1/2" A UNITWINDOW NOTES: · WINDOWS - ANDERSEN 400 SERIES, WHITE EXTERIOR, INTERIOR & HARDWARE. FULL INSECT SCREENS ON ALL OPERABLE UNITS. · ALL NEW EXTERIOR WALLS ARE 2X6 WITH 12" CONTINUOUS PLYWOOD SHEATHING AND 1" CONTINUOUS R-INSULATION. PROVIDE/ORDER EXTENSION JAMBS AS REQUIRED - COORDINATE WITH CONTRACTOR. MODEL REMARKSDESCRIPTION 2'-8 1/8" X 4'-4 7/8" C33 TW2642B DOUBLE-HUNG 3-WIDE CASEMENT 3/4" SDL GRILLES 6/6 NO GRILLS; TRADITIONAL FOLDING HANDLE; SHEETROCK RETURNS - NO EXTENSION JAMBS ALTERATION & ADDITION TO ARCHITECTS LLC 41 C NEW LONDON TURNPIKE, GLASTONBURY, CT 06033 DRAWINGS ARENOT TO BE SCALED DATE: 6.5.26 RELEASE: FOR PERMIT CONSTRUCTION DOCUMENTS PROJECT #26109 DALECKI & MAIER RESIDENCE 138 DAY STREETGRANBY, CONNECTICUT PROPOSED FIRST FLOOR PLAN A1.1 PROJECT NORTH NOTES: #1 - DIMENSIONS THAT ARE (±) ARE DIMENSIONS THAT REQUIRE FIELD VERIFICATION,ADJUST AS REQUIRED. DIMENSIONS WITHOUT A (±) ARE TO BE HELD. #2 - TOP OF EXISTING FIRST FLOOR, SUB FLOOR ASSUMED ELEVATION 0'-0". #3 - PLAN WAS DERIVED FROM DIGITAL SCANNING TECHNOLOGY. GENERAL CONTRACTOR TO FIELD VERIFY ALL EXISTING CONDITIONS AND REPORT ANY FINDINGS/DISCREPANCIES TO ARCHITECT PRIOR TO CONSTRUCTION START.
Page 358
Page 359
Page 360
Page 361
Page 362
Page 363
Page 364
Page 365
Page 366
TOWN OF GRANBY Incorporated 1786 15 North Granby Road Granby, Connecticut 06035-2102 1 May 28, 2026 Certified Mailing# 9489 0090 0027 6650 0481 77 Charles Duffy McGee III Duffy McGee PO Box 87 West Granby, CT 06090 Re: Notice of Violation: 65, 79, &87 Barkhamsted Road, Granby, CT (Mblu: G-20/66/3,4,&6) Conducting a Regulated Activity without a valid IWWC Permit Dear Mr. McGee: During a site inspection of an abutting property, it was noted that a portion of your properties appear to contain similar wetland resource areas as mapped and observed on the abutting property. As you may know, your properties are unique as they abut a productive watercourse, an unnamed tributary to the West Branch of the Salmon Brook, a Federally designated Wild and Scenic River. I have attached the town wetlands mapping as it relates to your properties and the link to information on the Lower Farmington River and Salmon Brook Wild and Scenic https://lowerfarmingtonriver.org/ and the National Parks link for the stretch of waterway https://home.nps.gov/articles/000/lower-farmington-salmon-brook- wild-and-scenic-rivers.htm (article is enclosed). On the Wild and Scenic River pages you can find maps which show the extent of designated rivers, and information surrounding activities associated with the rivers. Upstream of your property, the watercourse traverses over 3 miles of untouched marshes, gorges, and forests before it reaches your property. Geographically, your property is the first human development/activities (beside transportation crossings) to positively or negatively influence the integrity of the watercourse, before it reaches the West Branch of the Salmon Brook. We are looking forward to discussing this wetland resource area and your experiences living next to it in more detail. The Inland Wetlands and Watercourses Commission (IWWC) is charged with protecting the Town of Granby Wetlands and Watercourses as detailed by the Granby Inland Wetlands and Watercourses Regulations and applicable state laws. The Regulations require all work within a wetland resource area or the associated Upland Review Area (URA) obtain an approval from the IWWC. Review of Google Earth imagery appears to show some development activities on 87 Barkhamsted Road in November of 1991, which currently contains a single-family residence. The remaining property along this stretch of the watercourse appears to be undeveloped at that time. In May of 2004, aerial photographs indicate that activities may be occurring on all 3 properties. In November of 2010, aerial photographs indicate that all properties were being utilized, clearing and possibly grading had occurred, and that materials are being stored within mapped wetland areas. Current site observations and imaging indicate that the area is utilized for storage, and any clearing activities have ceased. The distinct nature of the activities and detailed location of wetlands resource areas (watercourse and wetland) has only been seen from the roadway, the adjacent property, and aerial photography. Material (wood working materials, cars, structures, equipment, etc.) are being stored within the wetland resource areas or their associated URA (100-feet from a wetland and 200-feet from a watercourse). At this time, all available data indicates that materials are stored or activities are being conducted within a regulated area without valid IWWC approval.
Page 367
2 In accordance with the Town of Granby Inland Wetland and Watercourses Regulations (IWWR), the work that occurred is considered a regulated activity as defined in said regulations and requires a permit application to be filed and an approval letter to be issued before commencing such activities in accordance with Section 6 of the regulations. These regulations can be viewed at the Granby Town Hall in the Office of Community Development or online at: https://www.granby-ct.gov/sites/g/files/vyhlif3171/f/uploads/iwwc.regulationsfinal.07-11-18.pdf. To fully understand the site conditions as they relate to the IWWR, it would be kindly appreciated if you would reach out to the Granby Office of Community Development to schedule a site visit to review activities within the mapped wetland resource areas on your properties. The site visit will allow the Town to better understand any errors in the Town wetlands mapping, if any “after-the fact” approvals are required, and answer any questions and provide information regarding wetland resource area protection and regulatory requirements. The Town understands that these activities have been in place for a period of time and would like to work with you to obtain IWWC approval for any activities you would like to continue within these areas. The goal is to protect wetland resource areas by preserving the natural landscape with balanced human use when adjacent to such a critical environmental resource. At this time, the Town reserves the right to initiate formal enforcement activities to achieve compliance or as necessary, document mitigation activities to be completed. As always, please contact the Granby Office of Community Development at (860) 844-5318 with any questions or comments and to set up a time to visit your properties. Sincerely, Kate Bednaz Authorized Wetlands Agent Town of Granby, CT
Page 368
From: Renee Deltenre To: Abigail Kenyon Subject: Fw: El Nino Weather forecase Date: Tuesday, June 16, 2026 10:39:53 AM From: Maureen Eberly <jeberly885@aol.com> Sent: Tuesday, June 16, 2026 10:05 AM To: Renee Deltenre <RDeltenre@granby-ct.gov> Subject: Re: El Nino Weather forecase CAUTION: This email originated from outside of the organization. Do not click links or open attachments unless you recognize the sender and know the content is safe. So I can update my list can you please send Sue and Barbara's new email? My original list came from Jen and once new members came on she hasn't had time to send me the new addresses. Thanks Maureen On Tuesday, June 16, 2026 at 08:30:20 AM EDT, Renee Deltenre <rdeltenre@granby-ct.gov> wrote: Received and distributed to Sue and Barbara. From: Maureen Eberly <jeberly885@aol.com> Sent: Tuesday, June 16, 2026 6:08 AM To: John Laudati <jlaudati@mlkbr.com>; David Tolli <dantolli@yahoo.com>; Nick Dethlefsen <ndethlefsen@gmail.com>; Victoria Dirienzo <v.dirienzo@cox.net>; fbjones1231@gmail.com <fbjones1231@gmail.com>; sueathorsesandhounds@gmail.com <sueathorsesandhounds@gmail.com>; Kate Bednaz <freshwaterwetland@gmail.com> Cc: Renee Deltenre <RDeltenre@granby-ct.gov> Subject: El Nino Weather forecase CAUTION: This email originated from outside of the organization. Do not click links or open attachments unless you recognize the sender and know the content is safe. Hello everyone, Below is an article describing the El Nino weather effects for the upcoming season. Renee- I do not have an email address for the new IWWC member.
Page 369
if you could please share with her, as I do not have an updated email address. Thank you Maureen Eberly El Niño Is Back. Here's How It Could Reshape Weather Patterns In Connecticut A rapidly strengthening El Niño could influence winter temperatures, snowfall and hurricane activity. Posted Thu, Jun 11, 2026 at 2:08 pm ET A fast-strengthening El Niño could significantly reshape weather patterns in Connecticut and across the Northeast later this year and into the winter months. The heightened risks vary widely by region, from heavy rain and flooding in parts of the Southwest and Southeast to drought and wildfire concerns in the Northwest, Northern Plains and Upper Midwest, according to a news release from AccuWeather, a private weather company. The update comes as federal forecasters declared El Niño conditions present in the tropical Pacific Ocean on Thursday after months of monitoring warming ocean temperatures. AccuWeather meteorologists said the current El Niño is unusual because it developed early and is expected to strengthen rapidly through the remainder of 2026. “El Niño is not a storm. It doesn’t affect you directly overnight. But the stronger the signal, the more it can dominate other weather patterns and amplify extremes,” AccuWeather meteorologist Paul Pastelok said. “This El Niño is developing unusually fast. Most El Niños begin in the fall.” El Niño is a natural climate pattern that occurs when sea surface temperatures in parts of the equatorial Pacific Ocean warm significantly above historical averages. That warming can trigger changes in global atmospheric patterns, shifting storm tracks and influencing rainfall,
Page 370
drought, wildfire risk and hurricane activity. What Could El Niño Mean For Connecticut? For residents in Connecticut and across the Northeast, El Niño could influence everything from winter temperatures and snowfall to the frequency of coastal storms. Historically, El Niño winters tend to favor warmer-than-average conditions across the Northeast while increasing the chances of a more active southern jet stream. That pattern can sometimes lead to wetter conditions and stronger nor'easters along the East Coast. Warmer overall temperatures can also complicate snowfall outcomes in Connecticut. While major snowstorms can still occur during strong El Niño years, overall snowfall totals often depend on storm tracks and the availability of cold air. Some of the strongest El Niño events on record have coincided with unusual winter weather across the Northeast. The powerful 1997-98 El Niño was associated with one of the warmest and wettest winters on record in parts of the country, while the 2015-16 "Godzilla" El Niño produced generally warmer-than-average conditions but still delivered a historic blizzard to parts of the East Coast. Meteorologists caution that no two El Niño events are exactly alike, and it remains too early to predict specific winter outcomes for Connecticut. Is ‘Super El Niño’ Still Possible? AccuWeather indicates a potential “Super El Niño” if equatorial Pacific temperatures reach 3.6 degrees Fahrenheit (2.0 degrees Celsius) above average. Pastelok estimates a 40 percent chance for this rare event, noting that current conditions must persist through late 2026 to reach that threshold. Only seven such events have occurred since 1957, according to the Climate Prediction Center’s Relative Oceanic Niño Index. The last one was in 2015-16.
Page 371
Hurricane Season Adjustments El Niño typically increases wind shear in the Atlantic basin. Wind shear, which is the change in wind speed and direction with height, can disrupt tropical storms and hurricanes before they organize or intensify. AccuWeather’s 2026 Atlantic hurricane season forecast projects 11 to 16 named storms. DaSilva said the early arrival of El Niño is causing forecasters to lean closer to 11 named storms than 16. “With El Niño’s arrival early in the hurricane season, we are now leaning closer to 11 named storms rather than 16 in the Atlantic this year,” DaSilva said. Stronger El Niño patterns have often contributed to increased wind shear across parts of the Atlantic, which can disrupt developing tropical systems and sometimes suppress hurricane activity. Even so, AccuWeather warned that a quieter Atlantic season does not eliminate the danger, especially from storms that form close to the U.S. coastline. Those “homegrown” systems can leave residents with less time to prepare. People along the coast and well inland should continue to monitor forecasts for tropical rainstorms, tropical storms and hurricanes. Outlook For The Rest Of U.S. Here’s what could be in store for the rest of the country. West Coast and California: California and parts of the Southwest could see increased moisture from eastern Pacific tropical storms and hurricanes, raising the risk of heavy rainfall, runoff, debris flows and flash flooding. AccuWeather said El Niño often has its greatest impact from late fall into early spring. During that period, heavier rain and mountain snow events can occur in California. Residents in wildfire burn-scar areas may face a higher risk of debris flows if heavy rain develops over vulnerable terrain.
Page 372
Southwest: The Southwest could see more moisture drawn northward from a busier eastern Pacific hurricane season. That could increase the risk of heavy rainfall and flash flooding in parts of the region, especially if tropical moisture interacts with storm systems. AccuWeather said this year’s eastern Pacific hurricane season is already running ahead of schedule. The basin’s third tropical storm, Cristina, formed almost a month earlier than the July 6 historical average for the season’s third named storm. “Warm water is one of the key ingredients in creating tropical storms,” AccuWeather hurricane expert Alex DaSilva said. “The rapid pace of early tropical storm development in the Eastern Pacific can be attributed to the near-record water temperatures observed in the Eastern Pacific. This is a very typical pattern in an El Niño set up.” DaSilva said a marine heat wave is underway from Baja South along the Central American coastline, where sea surface temperatures are 3 to 5 degrees Fahrenheit above historical averages in some areas. AccuWeather is forecasting 17 to 22 named storms in the eastern Pacific this year. Northwest: The Northwest could face a drier and warmer summer, AccuWeather said. That pattern could worsen drought in some areas and increase wildfire risk. The region may also miss out on consistent or intense precipitation during the wet season, which could contribute to longer-term drought concerns even after El Niño peaks. Northern Plains and Upper Midwest: The Northern Plains and Upper Midwest could also see a warmer, drier summer, which may prolong drought conditions in some areas. AccuWeather said drought concerns could linger for years in parts of the Plains after El Niño conditions peak, especially from Texas northward into the Dakotas.
Page 373
“Following the end of El Niño, the next two to three years could end up being significantly drier, leading to drought conditions, especially in parts of the plains from west Texas to the Dakotas,” Pastelok said. “El Niño patterns tend to be persistent, meaning places that end up drier than average can stay that way for an extended period of time, possibly for months or even years.” Central Plains: The Plains could see lingering drought impacts even after the strongest El Niño conditions subside. AccuWeather warned that pockets of severe to extreme drought could extend well into 2027 and potentially beyond in parts of the Plains from Texas to North Dakota. That could affect agriculture, water supplies, wildfire risk and regional heat patterns. Texas and the Southern Plains: The southern U.S. can initially see wetter conditions during El Niño, but AccuWeather said those conditions can reverse after the peak of a strong event. Parts of Texas and the southern Plains could face long-term drought implications in the years after El Niño, particularly if the pattern turns significantly drier. Gulf Coast: The Gulf Coast could see a wetter pattern from late fall into early spring, which may help ease ongoing drought in some areas. However, heavier rainfall can also increase the risk of flooding, especially in poor-drainage areas or places that receive repeated rounds of rain. Southeast: The Southeast could also see wetter conditions, particularly from late fall into early spring. AccuWeather said the pattern may help ease drought in the region, but it could also bring an elevated risk of excessive rainfall and severe weather. Florida may face a heightened severe weather risk during the mid-to-late winter season, which is typically the state’s drier time of year.
Page 374
A stronger southern storm track could increase the likelihood of severe weather in Florida and nearby areas.
Minutes: archived copy, SHA-256 e24d089949ab…. Agenda: archived copy, SHA-256 5051b4251ecd…. Packet: kept offline, SHA-256 1648d7c15b66….